Deforest Court-LR020426 (2)FIELD DENSITY TESTING
Report Number: 94021129.0006
Service Date: April 16, 2002
8901 Carpenter Fn,W., Suite #100
Dallas, Texas 75247
(214) 630-1010
'Client: The Holmes Builders
Attn: Dean Trudell
1406 Halsey Way Suite 100
Carrollton TX 75007
Report Date: April 26, 2002
Project: Single Family Home
632 DeForest Court
Coppell, Texas
Project Number: 94021129
Material Information
Material Laboratory
No. Test Method
Description and Classification
Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pcf) (%) (% compaction)
1. 211290013 ASTM D 698 Med. brown silty clayey sand
Field Test Data
Test Lift/ Mat.
No. Test Location Elevation No.
Building Pad
1 40' N & 25' E of fire place area
2 70' N & 5' E of fire place area
3 60' N & 25' W of fire place area
16.1 109.4 =/> +2 93
Probe Water Dry Unit Dry Unit
Depth Content Weight Weight
(inches) (%) (pCt') (% compaction)
At Grade 1 6 15.6 * 111.6 102
At Grade 1 6 13.7 * 109.5 100
At Grade 1 6 18.2 107.7 98
Comments:
An asterisk (*) appears next to test results which do NOT meet the project specifications.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method~,STM D2922, ASTM D3017
Gauge ID:
Technician: Phil Green
Report Distribution:
(1) The Holmes Builders
(1) City of Coppell - Constr Insp
(1) City of Coppell - Bldg Insp
Reviewed by:
HBC Engineering
Hussein ~aad, P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
matedals.