Amberpoint BP-LR020424 (3)CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0156 Service Date: March 27, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 24, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 8:15am Plant: 16 Supplier: Potter Truck No: 108 Mix I.D. No.: 7752 Field Test Data Test Ticket No: 612340 Sample Information Sample Time: 8:45am Date Cast: March 27, 2002 Technician: Steve Campbell Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Pump Sample Locations: See placement location Placement Location: Paving- Parking SW corner of building slab See attached sketch Result Specification Test Method Slump, inches: 7.25 5.0 Max ASTM C-143 Air Content, %: 7.1 4-8 ASTM C-231 Concrete Temperature,o F: 63 ASTM C1064 Ambient Temperature, o F: 51 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 04/03/2002 7 98,870 1 2 6.00 28.27 04/03/2002 7 98,650 Average 1 3 6.00 28.27 04/24/2002 28 133,180 1 4 6.00 28.27 04/24/2002 28 127,130 Average Maximum Compressive Load Strength (lbs) (psi) 3,500 3,490 3,500 4,710 4,500 4,610 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6 o~ LLW~Ol CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0156 Service Date: March 27, 2002 ENGINEERING 8901 Carpenter Fn~/y., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 24, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 9:12am Plant: 16 Supplier: Potter Truck No: 111 Mix I.D. No.: 7752 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 612350 Sample Information sample Time: 9:40am Date Cast: March 27, 2002 Technician: Steve Campbell Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Pump Sample Locations: See-page 1 Placement Location: See page 1 Result Specification Test Method 7.75 5.0 Max ASTM C-143 6.8 4-8 ASTM C-231 64 ASTM C1064 51 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 2 I 6.00 28.27 04/03/2002 2 2 6.00 28.27 04/03/2002 2 3 6.00 28.27 04/24/2002 2 4 6.00 28.27 04/24/2002 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 97,710 3,460 7 91,670 3,240 Average 3,350 28 120,210 4,250 28 116,580 4,120 Average 4,190 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Th~s report ~s exclusively for the use of the cl~en The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. ' ' ' .. indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0156 Service Date: March 27, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 24, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 10:43am Plant: 16 Supplier: Potter Truck No: 108 Mix I.D. No.: 7752 Field Test Data Test Ticket No: 612363 Sample Information Sample Time: 11:00am Date Cast: March 27, 2002 Technician: Steve Campbell Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page1 Result Specification Test Method Slump, inches: 5.00 5.0 Max ASTM C-143 Air Content, %: 6.1 4-8 ASTM C-231 Concrete Temperature,° F: 68 ASTM C1064 Ambient Temperature, c F: 60 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 04/03/2002 7 112,550 3,980 3 2 6.00 28.27 04/03/2002 7 111,710 3,950 Average 3,970 3 3 6.00 28.27 04/24/2002 28 136,270 4,820 3 4 6.00 28.27 04/24/2002 28 138,730 4,910 Average 4,870 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not bo reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0156 Service Date: March 27, 2002 ENGfNEEI~ING 6901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 24, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 11:55am Supplier: Potter Truck No: 109 Mix I.D. No.: 7752 Plant: 16 Field Test Data Test Ticket No: 612374 Sample Information sample Time: 12:10pm Date Cast: March 27, 2002 Technician: Steve Campbell Weather Conditions: Clear Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Result Specification Test Method Slump, inches: 5.25 5.0 Max ASTM C-143 Air Content, %: 6.4 4-8 ASTM C-231 Concrete Temperature,° F: 70 ASTM C1064 Ambient Temperature, o F: 63 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 1 6.00 28.27 04/03/2002 7 107,110 3,790 4 2 6.00 28.27 04/03/2002 7 105,080 3,720 Average 3,760 4 3 6.00 28.27 04/24/2002 28 128,410 4,540 4 4 6.00 28.27 04/24/2002 28 126,380 4,470 Average 4,510 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 4 of 6 o~ LLW~, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0156 Service Date: March 27, 2002 ENGINEERING 8901 Carpenter Frwy., Suite $100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 24, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 12:32pm Supplier: Potter Truck No: 108 Mix I.D. No.: 7752 Plant: 16 Field Test Data Test Ticket No: 612382 Sample Information sample Time: 12:45pm Date Cast: March 27, 2002 Technician: Steve Campbell Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Result Specification Test Method Slump, inches: 5.00 5.0 Max ASTM C-143 Air Content, %: 6.2 4-8 ASTM C-231 Concrete Temperature,° F: 70 ASTM C1064 Ambient Temperature, o F: 64 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 5 I 6.00 28.27 04/03/2002 7 90,180 3,190 5 2 6.00 28.27 04/03/2002 7 90,330 3,190 Average 3,190 5 3 6.00 28.27 04/24/2002 28 115,870 4,100 5 4 6.00 28.27 04/24/2002 28 113,470 4,010 Average 4,060 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the'client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, Page 5 of 6 ~Lw~o~.~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0156 Service Date: March 27, 2002 I~'NC~I~F~ER~N~ 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) §30-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: April 24, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 1:53pm Supplier: Potter Truck No: 104 Mix I.D. No.: 7752 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 6.25 7.0 76 67 Ticket No: 612394 Sample Information Sample Time: 2:05pm Date Cast: March 27, 2002 Technician: Steve Campbell Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Specification Test Method 5.0 Max ASTM C-143 4-8 ASTM C-231 ASTM C1064 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 6 1 6.00 28.27 04/03/2002 6 2 6.00 28.27 04/03/2002 6 3 6.00 28.27 04/24/2002 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 84,260 2,980 7 86,200 3,050 Average 3,020 28 108,270 3,83~ 6 4 6.00 28.27 04/24/2002 28 112,350 3,970' . j . Average ~ _ ~/.3,900 /.~ _ - Comments: Does not comply with specified strength. - ~-~,~.~J~_.~ _ Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressrve /~..~ strength samples. Technician: Steve Campbell Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell- Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6 0~.LLW~.O~