Loading...
WA9302A-SP 960320 (2) North Texas Municipal Construction Company, Inc. SUBMITTAL NO. 1 ~820-01 5614 Dyer St. Dallas, Texas 75206 City of Coppell 214/368-6880 Village Parkway Pump Station FAX 214/368-4950 Specification: Fans ...... ~ RE~EG[ED C] RE'i~S~ AN~ ~,ESU ~'~ ~0 EXCEPTIONS TAKEN D MAKE CO~RSCTiONS NOTED ' D SUB~IT S~EOiRED ~TE~i~ Q REJECTED D F:EV~SE A~-~::= Q SUB~,~IT SPECkFED ITEM COrrections or comments made on trio shop Drawrags dur- with 'at u,,or.'lcnts c;; the c;-~wmtls add SpcG..h:=mons. ing this review do not rofle%'8 cc ~t~act Dr h',Dm Co~pl,,8~ce Ct~ck work w~th Ill~t ~ ~II omer tn~ac~s. and ~r/urinmg his f~lGCT;:~':?'.%~'/$ ~;%$C)C~AT~S, ~'~C. M~C:~SARV ~ ASSOC~Af~e' ~NC. ' CONSTRUCTION · SALES · SERVICE . - I~ ACME ENGINEERING & TUBEMASTER® FANS MANUFACTURING CORP. TUBEAXIAL P. O. Box 978 MODEL HA Muskogee, OK 74402 BELT DRIVE Project Village Parkway Pump Station MOTOR SHIPPED -- D - Location Coppell, TX NOT MO___UNTE____D ~ Architect Engineer ff__i j! C°ntra~°rNorth Texas Municipal ','lI ", Submitted by H .R Capers Co. ,,! Date ', ~,,,~ March 5, 1996 )t2/l4 ~,~-~.,.---..,-'t %;>1 These are typical drawings for dimensional purposes only, which are iB C i iFL ~,,i, ;w..~==~.,~ ~ ~, c~ orrect within limits suitable for normal installation requirements and do ._~__'Z"_":Zi":_j ,,''~ not necessarily show actual construction. i/ WARNING! DO NOT use in HAZARDOUS ENVIRONMENTS where / ,,z fan's electrical system could provide ignition to combustible or flam- mable materials, unless unit is specifically built for hazardous environ- HOUSING-"" °~ ments. OOR CAUTION! Guards must be installed when fan is within reach of per- ~x"--MOUNTING BASE sonnel or within seven (7) feet (2.134 m) of working level or when (OPTIONAL EXTRA) deemed advisable for safety. i i Oty. i Metal Gauge Fan A ~ B C D F ~ G lots Shaft Size {Access Door ', I I of Housing s'zeI,Nimm l,Nlmm ,Nlmm ~,Nlmm ,N[mmI IN I mm S IN]ram: IN mm Sa. i mm HA12 '14'1/,6] 373 137/16 I 341 123/16 ] 310 12 ~ 305 17 432 '5/16x7'/,6 8xll 6 s/e 16 i None None 16; 1.52 HA16 183/4 ~ 476 171/2 445 161As~ 408 161/2 i 419 19 483 ~'16xTAs 8xll 8 7/e 22 10x 8'254x203 16 1.52 HA24 27 686 25~/4 ! , I HA30 1333/4 I 857 321/4 ' 819 30Va 775 24 610 j 29 737 746xg/~6illx14! 8 13/t6 30 !12x14 305x 12 ! 2.66 i ~HA36 [393/4 i 1010 ! 38V4 972 k36'/~ 927 29 ] 737 ! 32 813 7/,sxg/,etllx14:. 8 I 13A6 30 !12x17 305x432] 12 I 2.66 I = 37 il 2 x 17 305 x 432 ~ 12 ~ 2.66 HA42,,46~,,, !t~62 1441~4 t124 42v21060 32 I 613 37 940!9~,~,,,A~!14xtTl ~it~,,,~I , 12.66 ~EATURES LEGEND The precision balanced propeller is all aluminum with minimum L-50 life of 200,000 hours. Bearings are resilient die-formed circular-arc airfoil blades a~ached to the mounted in neoprene rings providing protection and MOTOR special die-formed spherical hubs for high aftlow capacid. vibration isolation. O Open (Dripproof) TE - Totally Enclosed EX Explosion Proof The ac~lic epoxy finish fan housing is constructed of Drives are cast iron pulleys with static conducting oil and 2S Two Speed heavy gauge steel and includes a full streamline belt and heat resistant belts and are designed for 1.5 seNice OPTIONAL CONSTRUCTION bearing enclosure to increase efficiency. The housing has factor. The fan shaft has a zinc phosphate coating with an CF Companion Flanges an access door (except size 12) for internal inspection and oil emulsion dip for additional resistance against FG Fan Guard an integral rolled flange for structural ngi0~ and to corrosion. MB Mounting Base eliminate leakage at the flange connection, WC Motor Weather Cover Sealed ball bearing motors are mounted out of the ST SteeiPropeller The rugged motor base is adjustable with a screw jack. airstream. PB Pillow Block Bearings (Sizes 16 - 48) Pre-lubricated ball bearings are used in the "captured" All fans are licensed to bear the AMCA Ce~ified Ratings EH Eisenheiss Coating bearing housing for accurate alignment and to provide a Seal for Sound and Air performance. HS Heresite Coating EF-4 1 HA42M 30.0 3 460/3 TE iMB,WC, ' I I Adj us tab le ~ ! V-Drive ! I 'Certified sound ratings in decibels for each of the 8 octave bands, in Lw(A) decibels and in sones are available upon request. Submittal Sheet No. 8J-1 Acme Engineering & Manufacturing Corp. reserves the right to change specifications without notice. SECTION 7 0892 ' " ,.",. .... ... He '~_~ ~ ~ ~T~L FOR ~WER ~T ~ ~ ~ ~T~ ~T ~ VERT~ ~ ~T~ ~T UN~ S~E H W D A e C E F G J K L M N P O R S T U V X Y Z ~ as MOUNTING BRACKET~ ~&~ 1~ 14tsl~ 6~ 11~ I1~ '~ 1~ 5~ 8 57/:s ls~ 4~ ~/:s 5 ~ 13 9~ 12V4 !1~ 8 10~ 21"~ 13 9V4 19V, 1~ U~ ~ Venk 07 & 10 24~s, 21~ 6h 15V4 15~4 ~ 27/a 5V4 13 ~ Ih 7h 2~ 6h ~:s 1~ 131~ 18 16~/1, 13 12 ~ 14~ 19h ~ 13~ 3.3 to 50 KW ~1~ V51~ 15 & ~ 28"As 21~ 6h 15V4 15Y4 4~e 2z~ 5V4 13 ~ I~ 7h 2h 6h ~** 1~ 13~ 18 ~1:, 13 12 2~a 14h 19~ 23 13~ 7.5 to ~+0 KW ~1~ V51~ 25 THRU ~ ~ ~V4 10%e ~Y4 ~Y4 ~ ~ 8~s 13 ~ 1~ 9h 3 6h 42 21 13~ 18 ~h 13 13~ 28~ 15~ 19~ ~ssl~ 14a~ 250 ~ ~-0 KW ~i~ V515 HEATER MOTOR AIR QTY, TAG MODEL NUMBER BUILT~N CONTROLl KW VOLT8 PHASE VOLT8 R.P.M. C.F.M. F.P.M. 1 ~3~5ll0CAZ~ ~0 ~80 3 ~80 Z550 700 Z000 ACCE88ORIE8 - DESCRIPTION 1 A5120 Wall Mounting Bracket 1 T5100 Ingegral T-Stat Project: Village Parkwa~ P~p Station Location: Coppell, TX Contractor: North Texas Municipal