Amberpoint BP-LR020509CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0258 Service Date: Apdl 30, 2002 Client: Transwestem Commemial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Fwvy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 09, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. ~;} Coppell Coppell, Texas Project Number: 94021029 Mate~fal Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 1:07pm Supplier: Potter Truck No: 108 Mix I.D. No.: 9337 Plant: 16 Ticket No: 613511 Sample Information Sample Time: 1:34pm Date Cast: April 30, 2002 Technician: Geny Graham Weather Conditions: Fair, mostly clear Accumulative Yards: 388 Placement Method: Direct Discharge Sample Locations: SP/1 and SP/2 Placement Location: Piers Field Test Data Test Result Slump, inches: 7.25 Air Content, %: Concrete Temperature, o F: 83 Ambient Temperature, o F: 83 Plastic Unit Weight, pcf: Laboratory Test Data Specification Test Method 5-7 ASTM C-143 N/A ASTM C1064 ASTM C-t 064 Age at Test (days) Set Specimen Diameter Ama Date No. ID (inches) (sq. inches) Tested 1 I 6.00 28.27 05~07/2002 1 2 6.00 28.27 05/07/2002 7 Average I 3 05~28/2002 28 1 4 05/28/2002 28 Maximum Compressive Load Strength (lbs) (psi) 98,820 3,490 92,130 3,260 3,380 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Gerry Graham Report Distribution: (1) Transwestem.Commercial Services (1) O'Brien & Associates Inc (1) TechniStruotures Inc (1) City of Coppell- Constr Insp (1) City of Coppell- Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC En~ng Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced excel3{ in full without the wrfften approval of Terracen. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0260 Service Date: April 30, 2002 Client: Tmnswestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: May 09, 2002 Project: Amberpoint Building No. I 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number.' 94021029 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 7:50am Supplier: Potter Track No: 102 Mix I.D. No.: 9337 Plant: 16 Ticket No: 613481 Sample Information Sample Time: 8:25am Date Cast: April 30, 2002 Technician: Marvin Arandia Weather Conditions: Partly cloudy Accumulative Yards: 90 Placement Method: Pump Sample Locations: Panel #21 Placement Location: Panels ~r20, #21, fY23, ~89A, #89B, #89C, #1, #87, ;~88, ~29 #99A, #99B & #99C Field Test Data Test · Result Slump, inches: 5.50 Air Content, %: 1.6 Concrete Temperature,o F: 74 Ambieht Temperature, o F: 75 Plastic Unit Weight, pcf: Laboratory Test Data Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Test (days) Set Specimen Diameter Area Date No. ID (inches) .(.sq. inches) Tested 1 1 6.00 28.27 05/07/2002 7 110,500 1 2 6.00 28.27 05/07/2002 7 113,380 Average 1 3 05/28/2002 28 1 4 05/28/2002 28 Maximum Compressive Load Strength (lbs) (psi) 3,910 4,010 3,960 Services - ·Obtain samples of fresh concrete at the placement locations, perform required field tests and 'cast compressive strength samples. The tests were perforated in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated, above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4 o~.ss~. CONCRETE COMPRESSIVE STRENGTH TEST Report Number.- 94021029.0260 Service Date: April 30, 2002 Client: Transwestem Commemial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Ftwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 09, 2002 ProjeCt: Amberpoint Building No. 1 Amberpoint Bus. Pk. ~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: 8:42am Supplier: Potter Truck No: 103 Mix I.D. No.: 9337 Plant: 16 Ticket No: 613492 Sample Information Sample Time: 9:22am Date Cast: April 30, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 190 Placement Method: Sample Locations: Panel #29 Placement Location: See page 1 Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 1.5 Concrete Temperature, o F: 75 Ambient Temperature, o F: 78 Plastic Unit Weight, pcf: Laboratory Test Data Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 05/07/2002 7 109,970 3,890 2 2 6.00 28.27 05/07/2002 7 109,140 3,860 Average 3,888 2 3 05/28~2002 28 2 4 05/28/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repe~t is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0260 Service Date: April 30, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 ENG~ 8901 Carpenter Fnvy., Suite#100 ' Dallas, Texas 75247 (214) 630-1010 Report Date: May 09, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. ~;~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 PSi ~ 28 Days BatchTime: 9:25am Plant: 16 Supplier: Potter Track No: 105 Mix I.D. No.: 9337 Ticket No: 613498 Sample Information Sample Time: 10:15am Date Cast:April 30, 2002 Technician:' Marvin Arandia Weather Conditions: Partly cloudy Accumulative Yards: 260 Placement Method: Pump Sample Locations: Panel ~99B Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.75 ASTM C-143 Air Content, %: 1.3 ASTM C-231 Concrete Temperature? F: 75 ASTM C1064 Ambient Temperature, o F: 80 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 05/07/2002 7 90,120 3,190 3 2 6.00 28.27 05/07~2002 7 95,010 3,360 Average 3,280 3 3 05/2812002 .28 3 4 05/28/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicab~ ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are enly applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0260 Service Date: April 30, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214)630-1010 Report Date: May 09, 2002 · Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 10:05am Plant: 16 Supplier: Potter Track No: 110 Mix I.D. No.: 9337 Ticket No: 613503 Sample Information Sample Time: 10:50am Date Cast:April 30, 2002 Technician: Marvin Arandia Weather Conditions: Partly cloudy Accumulative Yards: 310 Placement Method: Pump Sample Locations: Panel 88 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.50 ASTM C-143 Air Content, %: 1.4 ASTM C-231 Concrete Temperature,o F: 75 ASTM C1064 Ambient Temperature, o F: 86 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 1 6.00 28.27 05/07~2002 7 113,660 4,020 4 2 6.00 28.27 05/07/2002 7 109,250 3,860 Average 3,940 4 3 05~28~2002 28 4 4 05/28/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestem Commemial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Conatr Insp (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC Engine/ Eugene Hart)our Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracoft. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4