CF-Coppell Rd SC-LR020501 (2)Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPORT OF CONCRETE TESTS JOB NO.:
CLIENT: Texas Unified Constructors, Inc. DATE:
PROJECT: ,eld Service a,nt. Fac., Coppell SUPPLIER:
LOCATION OF POUR SET 1: Precast wall panels,#9, 10, 11 and half of 12
LOCATION OF POUR SET 2:
01.1054
1 May 2002
Lattimore
SAMPLE DATA: SET 1 SET 2 MIX NO. 65
Truck No. 822 Cement
Ticket No. 3144011 Flyash
Time Batched 10:00am Sand
Time Sampled 10:31 am in.
Concrete Temp. (ASTM C1064) 82°F 1.0 in.
Air Content ~ASTM C231) 5.8% Water
Unit Weight IASTM C1381 Admix//1
Admix #2
AEA
COMPRESSIVE STRENGTH TESTS ;ASTM c3a)
(Standard 6 inch x 12 inch cylinder)
Cylinder Slump Age Test
Number Inches Days Date
(ASTM C143)
228 4.50 ~05/08/02
229 4.50 05/29~02
230 4.50 28 05/29/02
Total Load Compressive Required
Pounds Strength 28-Day
psi Strength
83,200
28-Day Average 4000
TECHNICIAN:
DISTRIBUTION:
CBC (10:00am.12:0~~
of co,,o,
(1) Doyle Engineering Group
(1) Texas Unified Constructors, Inc.
2870 Walnut Hill lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148