Loading...
ST0001-LR020506 (2)8908 Amb~dor Row ~ Tex~ 75247-4510 (214) 630-9745 (214) 63o-9819 (ax) CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Copl~ll Report No.: 147230 Attn: Ms. Susan Taylor - Engineering Dept Project No.: 015729 PO Box 478 Date of Service: 04/05/2002 C~----" '~ ~^'" Report Date: 05/06/2002 Project:~kview Drive and j f Fr~-port Parlcwa~ $~¢~.'l'~W~ampl~ of fr~h ~oncr~t~ ~: the pl~a~t Ioc~'ion~. i~form r~luimd fi~ld ~ ~ eompr~ive ,tr~.h ~mpl~ ~nd bring ~mpl~ b~k to the l~boml~j for m~ring PROJECT DATA STRENGTH: SLUMP On): AIR (%): TEST METHOD: com-~o~c'roR: Infrastructure Services, Inc. CONCI~TE SUPPLIER: Lat~llore PLANT: 3 S~ZClZlCATIO~ RZQVIRZMENTS 3000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C- 172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 42 PLACEMENT DATE: 04/05/2002 WEATHER CONDITIONS: Partly cloudy TIMESAbIPLED: 10:20am BATCHTIME: 9:18am TE~ERA~ff)-Am 60 F CONCRgTE: 70 F T~UCg NO: 1124 TIC~C~T NO: 3142726 Am cot~rE~rr (%): NA v~rr WZiG~rr (pc0: NA OVERALL PLACEMENT LOCATION: Paving o Froepott from Stntion 31+50 to St~ion 36+.03 SAMPI~ LOCATION: Station 32+50 REPORT OF TESTS Concre~ Compressive Cylinder 6" x 12" (ar~ 28.27 ~q. in.) CYLINDER MEASURED MAXIMUM COMER~SSIV~ MARKED SLUMP DATE AGE LOAD STRENGTH FRACi'URE SET NO, 0nches) TESTED (days) Obs. force) (psi) TYPE 1 I 3.75 04/09/2002 4 90530 3200 Unbonded Cap 1 2 3.75 04/12/2002 7 99750 3530 Unbonded Cap 1 3 3.75 05/03/2002 ~ 127440 ~ Unbonded Cap 1 4 3.75 05/03/2002 ~ 128930 ~ Unbonded Cap Average 1 5 Hold L/MrrATIONS: 'Fac te*t rt~ults pr~entod helm ~ pmp~md breed upon ~ ~c ~1~ ~ ~ ~ We ~ ~ ~m~ ~ ~ h q~i~ (~i~ ~, ~, ~.) ~ ~y o~ f~ of s~ ~t ~ ~ ~ ~ ~ ~ ~ w~ we ~ve ~ ~1. ~ 1~ ~ ~m ~ f~ ~e ~cl~ive me of~e cU~ W whom ~ ~ ~ ~ ~ ~t ~ ~ ~a~ ~ ~ ~ ~c ~ ~u~ of~ ~, ~. 01OK Page 1 of 6 Report No.: 147230 RoneEngine~rs Project No.: 015729 l]/ Client: City of Coppell CYLINDER MEASURED MAXIMUM COMPRE~IVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACi'URE SET NO. (inches) TESTED (days) (lbs. force) (IM) TYPE LIMITATIONS: The tcst t~ults presented her~-in were ~t, ared based uixm the speoifi~ sam~. Ica pmvidcd for t~ting. We assume no l'~pomibility for variation in quality (composition, appearance, performance, crc.) or any other feature of similar subject matter Movided by porous or conditions over which we have no control Our letters and relx~r~ a~ for thc cxclusivc use of the clicats to whom thcy are addressed and shall not be t~.~e, oduced except in full without thc written at, lau~al, of Rono Bn~/ncors, Inc. OlDK Page 2 of 6 gineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: l'roject: services: City of Coppell Arm: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 147230 Project No.: 015729 Date of Service: 04/05/2002 Report Date: 05/06/2002 Crcekv/ew Drive and Freeport Parkway Coppcll, TX Obtain samples of fresh conerctc at the placement locations, perform required field test/ng, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance w/th applicable standards. PROJECT DATA STRENGTH: SLUMP On): AIR (%): TEST METHOD: co~croR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 3 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C- 172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN LD.: 42 PLACEMENT DATE: 04/05/2002 WEATHER CONDITIONS: Stmny T~MESAMeJ. ED: 12:30pm n~.TCaTtiV~: ll:39am r~MPZRArm~-nm 62 F concRETE: 78 F r~uc~: no: 1026 ~nc~'r no: 7115227 nmconTENT ¢%): 4.8 t~TrW~.IGHY (pc0: NA O~L P~CE~ ~A~ON: ~l - F~ ~m S~ ~ ! +$0 ~ S~ ~.03 SAMPLE LOCATION: Station 33+66 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (nrea 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (d~ys) Obs. foree) (psi) TYPE 2 1 3.25 04/09/2002 4 105690 3740 Unbonded Cap 2 2 3.25 04/12/2002 7 114350 4040 Unbonded Cap 2 3 3.25 05/03/2002 28 148745 5260 Unbonded Cap 2 4 3.25 05/03/2002 28 152600 5400 Unbonded Cap Average 5330 2 5 Hold LIMITATIONS: Thc test results presented hetdn were ~ based upon the specific samples p~vldod for testing We assume no re,potability for ravin'on in qualit~ (composition, appearance, performance, etc.) or any othcr feature of s/mihr subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of thc clients to whom they are nfldr~d and ~ not be reproduced except in full without the written approval of Rone En~ainee~s, Inc. 01DK Page 3 of 6 Report No.: 147230 Project No.: 015729 Client: City of CoppeIl RoneEngineers CYLINDER MEASURED MAXIMUM COMPRESSIVK MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. 0nches) TESTI~D (days) 0bL force) (psi) TYPE LIMITATIONS: The test rcsults pre, cared herein wc~ ~ based u~on the specific samples providcd for te~ting. We assume no rcspomibility f~r variation in quality (composilion, appearance, pcrfinnnnnc, e. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our iettcr~ and report~ are for the exclusive uae of the clients to whom they are -a,4,~:aaed and shall not be ,~,,~duced except in full without the written a~,p,~oval of Ronc Bna. Inc. OlDK Page 4 of 6 RoneEngineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Atto: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 147230 Project No.: 015729 Date of Service: 04/05/2002 Report Date: 05/06/2002 Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of fi~esh conere~e at the placemant locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standnrd~ PROJECT DATA SLUMP (iu): Am (%); TEST M~THOD: COr~T~CTOR: Infrastructure Services, Inc, CONCRETE SUPPLIER: LaRimorc PLANT: 3 SPECIFICATION REQUIREM]ENTS 3000 psi ~ 28 Days T' - 5" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-23 ! ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN LD.: 42 eL~C~m' DATE: 04/05/2002 WEATHER CoNDmONS: Sunny TIME SAMPLED: 3:10pm BATCHTIME: 2:01pm ~so, EaA~.n~ O~-Am 65 F CONC~rZ: 80 · r~vc~ NO: 956 TIC~T ~o: 7115240 ~ Co~ (%): 4.2 ~ WEIG~ ~c0: NA O~l.L p~ ~A~ON: Pav~ - F~ ~m S~n 31+50 ~ SAMPI.~ LOCATION: Station 36+.03 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (men 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD ~r~ENGTH FRACTURE SET NO. (inches) TESTED (days) Obs. foree) (psi) TYPE 3 1 4.5 04/09/2002 4 80990 2860 Unbonded Cap 3 2 4.5 04/12/2002 7 97390 3440 · Unbonded Cap 3 3 4.5 05/03/2002 28 124795 4410 Unbonded Cap 3 4 4.5 05/03/2002 28 122540 4330 Unbonded Cap Avernge 4370 3 5 Hold LIMITATIONS: The test results presented heroin v~re prepared breed upon th~ specific samples provided for te~ng. We assume no respondbility for v~riation in quality (compo$it/on, appearame, pcrformm~cc, etc,) or any other featurc of simila~ subject matter pmv/ded by persons or conditions over which we have no control. Our lctte~ and reports are for thc exclusive usc of the clients to whom they are addresscd end shall not bc r c~vduced except in full without the written approval of he En~inecrs, Inc. 01DK Page 5 of 6 Report No.: 147230 Project No.: 015729 CYLINDER MARKED SET NO. MEASURED SLUMP Client: City of Coppell DATE AGE TESTED (days) in--rs MAXIMUM LOAD Ob~. force) COMPRESSIVE STRENGTH (pa) FRACrLq~E TYPE Technician: Cody Carroll Report Distribution: (1) city of c~l~ (1) city of co~n~l~ (1) City of COPl~ll (1] Infrasm~tu~ Scx~ic~, Inc. Started: 7:00am (1) City of Coppoll (I) Schrickel, Rollins & Assoc., Inc. Fini.~hed: 5:00~m LIMITATIONS: The test results presented herein were prepared based upon the specific samplm provlc~l ~r testing. We assume no respomib~ty for variation in quality (composition, appeanmce, performance, eta.) or any other feature of similar subject matter provided by persons or conditions over which we have no conlrol. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be ~eln~luced except in full without the written al~lnoval of Rone Engjneerz, Inc. 01DK Page 6 of 6