CF-Coppell Rd SC-LR020507 (2)Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPOR~
CLIENT: Texas Unifi , .
PROJECT: Field Service Offices & Maint. Fac., Coppell
JOB NO.:
DATE:
SUPPLIER:
LOCATION OF POUR SET 1: Precast wall panels #1, 2 and half of 3
LOCATION OF POUR SET 2:
01.1054
7 May 2002
Lattimore
SAMPLE DATA: SET 1 SET 2 MIX NO.
Truck No. 1042 Cement
Ticket No. 7116283 Flyash
Time Batched 2:12pm Sand
Time Sampled 3:00pm in.
Concrete Temp. (ASTM C1064) 83°F 1.0 in.
Air Content IASTM C2311 Water
Unit Weight (ASTM C138) Admix #1
Admix #2
AEA
65
COMPRESSIVE STRENGTH TESTS (ASTM C39)
(Standard 6 inch x 12 inch cylinder)
Cylinder Slump Age
Number Inches Days
{ASTM C143)
234 4.50 ~
235 4.50
236 4.50 28
237 4.50 28
Test Total Load
Date Pounds
05/13/02 81,400
05/14/02 87,600
06/04/02
06/04/02
Compressive Required
Strength 28-Day
psi Strength
28-Day Average 4000
TECHNICIAN:
DISTRIBUTION:
MFM (3:00pm-4:00pm)
(3) City of Coppell
(1) Vidaud & Associates
(1) Doyle Engineering Group
(1) Texas Unified Constructors, Inc.
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148
Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPORT OF MORTAR/GROUT TESTS
CLIENT: Texas Unified Constructors, Inc.
PROJECT: Field Service Offices & Maintenance Fac.
Coppell, TX
LOCATION OF POUR SET 1:
LOCATION OF POUR SET 2:
JOB NO.: 01.1054
DATE: 7 May 2002
SUPPLIER: Quality Masonry
Block walls at utility storage building, approx. 10'-30' east
of northwest corner, approx. 8'-I0' above finished floor
SAMPLE DATA: SET 1
Truck No.
Ticket No.
Time Batched
Time Sampled 2:1 Opm
Mortar Temp. (ASTM C1064) 83°F
Air Content (ASTM C173)
Unit Weight IASTM C138)
SET 2 MIX NO. Type "S" Mortar
Cement
Cement
Sand
in.
1.0 in.
Water
Admix //1
Admix //2
AEA
COMPRESSIVE STRENGTH TESTS (ASTM C39}
(Standard 2 inch x 2 inch x 2 inch Cube)
Cube Flow Age Test Total Load Compressive Required
Number % Days Date Pounds Strength 28-Day
psi Strength
237 7 05/14/01
238 28 06~04/01
239 28 06~04/01
4,300 1080
28-Day Average 1800
TECHNICIAN:
DISTRIBUTION:
MFM (2:00pm-3:00pm)
(3) City of Coppell
(1) Vidaud & Associates
(1) Doyle Engineering Group
(1) Texas, Unified Constructors, Inc.
2870 walnut Hill Lane Dallas. Texas 75229 (214) 351-6419 Fax (214) 351-5148