Amberpoint BP-LR020515CON. CRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021029.0248
Service Date: April 26, 2002
Client: Transwestern Commercial Services
At[n: Jim Gaspard
5001 Spring Valley Rd. Suite 600W
Dallas TX 75244
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
~ ~,~214) 630-1010
Re~ May 15, 2002
Pr(~ect." Arnberp~
'~==~ffITBus. Pk. @ Coppell
Coppell, Texas
Project Number: 94021029
Material Information '
Specified Strength: 3000 psi @ 28 Days
Batch Time: 7:10am Plant: 16
Supplier: Potter
Truck No: 116 Ticket No: 613400
Mix I.D~ No.: 9337
Sample Information
Sample Time: 7:35am Date Cast: April 26, 2002
Technician: Marvin Arandia
Weather Conditions: Cloudy
Accumulative Yards: 10
Field Test Data
Test Result Specification Test Method
Slump, inches: 5.50 ASTM C-143
Air Content, %: 1.6 ASTM C-231
Concrete Temperature, o F: 73 ASTM C1064
Ambient Temperature, o F: 56 ASTM C-1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
1 1 6.00 28.27 05/03/2002 7 131,300 4,640
1 2 6.00 28.27 05/03/2002 7 134,900 4,770
Average 4,710
I 3 05~24~2002 28
1 4 05/24/2002 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted'herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 6