Amberpoint BP-LR020516REPORT OF REINFORCING STEEL OBSERVATION ENG~, INC. 8gOI Ca~e.~ Pnvy~ Sui~ #100 Deb] ?e~ 7~247 Date of Service: 05/16/02 Client No.: 3181 Client: Transwestcrn Commercial Services 5001 Spring Valley Rd, Suite 600 W Dallas, TX 75244 Report No.: 94021029.0282 Project No.: 94021029 Project: Ambcrpoint Building No. 1 Amberpoint Bus. Pk. ~ Coppell Coppell, Texas Services: Drawings Utilized: Locations/Items Observed: Observe placement of reinforcing for compliance with furnished drawings. PROJECT DATA Civil Pavement, SW of building Test Method: Vis-o! Observation REPORT OF OBSERVATION Discrepancies/Comments: Any discrepancies found were corrected at the time of this observation unless otherwise noted. Field Re~ult~ RepoR To: Technician: M. Arandia Rooo~t D~tributlon: (1) Transwestem Commercial Scndccs (1) (:TBfien &Associatcs, Inc. (I) TcchniSuucturcs, ln~. O) city ofCopt~n - Conm. hup. ~ Engi~eeriag, he. (1) City of Coppell - Bldg. lnsp. (1) Hill & Wilkinson, Ltd. (1) H~lffAsso~i~x.s O) stm ~... ~m.~ Eugene Harbour PROJECT: PROJECT NO.: CALCD. BY: CHKD BY: [Bill DATE: DATE: ENGINEERING, INC. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0216 Service Date: April 16, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 9:37am Supplier: Potter Track No: 110 Mix I.D. No.: 9349 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature? F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 4.50 1.2 78 72 Ticket No: 612977 Sample Information Sample Time: 4:25am Date Cast:April 16, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Pump Sample Locations: B.8, 10.9 Placement Location: Slab Lines A-C, 3-11 Specification Test Method Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested I 1 6.00 28.27 04/23/2002 1 2 6.00 28.27 04/23/2002 1 3 6.00 28.27 05/14/2002 1 4 6.00 28.27 05/14/2002 ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 143,030 5,060 7 138,930 4,910 Average 4,990 28 171,250 6,060 28 168,770 5,970 Average 6,020 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the usa of the client indicated above and shall n~ be rep;educed except in full without the written approval of Terracofl. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of uther apparently similar or identical materials. Page 1 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0216 Service Date: April 16, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 63o-101o Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 4:52am Plant: 16 Supplier: Potter Truck No: 105 Mix I,D. No.: 9349 Field Test Data Test Ticket No: 612986 Sample Information Sample Time: 5:30am Date Cast: April 16, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 110 Placement Method: Pump Sample Locations: 10.1,.A.5 Placement Location: See page 1 Result Specification Test Method Slump, inches: 5.50 ASTM C-143 Air Content, %: 1.3 ASTM C-231 Concrete Temperature, o F: 72 ASTM C1064 Ambient Temperature, o F: 78 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 04/23/2002 7 115,090 4,070 2 2 6.00 28.27 04/23/2002 7 116,190 4,110 Average 4,090 2 3 6.00 28.27 05/14/2002 28 144,460 5,110 2 4 6.00 28.27 05/14/2002 28 140,630 4,970 Average 6,040 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were pedormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not ,necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0216 Service Date: April 16, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Finny., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. ~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 5:29am Plant: 16 Supplier: Potter Truck No: 115 Mix I.D. No.: 9349 Field Test Data Test Ticket No: 612994 Sample Information Sample Time: 6:04am Date Cast:April 18, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 200 Placement Method: Pump Sample Locations: A.5, 9.2 Placement Location: See page 1 Result Specification Test Method Slump, inches: 5.50 ASTM C-143 Air Content, %: 1.3 ASTM C-231 Concrete Temperature, o F: 79 ASTM C1064 Ambient Temperature, o F: 72 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 I 6.00 28.27 04/23/2002 7 134,530 4,760 3 2 6.00 28.27 04/23/2002 7 132,430 4,680 Average 4,720 3 3 6.00 28.27 05/14/2002 28 151,830 5,370 3 4 6.00 28;27 05/14/2002 28 157,090 5,560 Average 5,470 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were parformed in general accordance with applicable ASTM, AASHTO, or DOT test mst. heds. This report is exclusively for the usa of the client indicated above and shell nct be reproduced excap~ in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 o,~_w~,...~, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0216 Service Date: April 16, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number.' 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 6:14am Supplier: Potter Track No: 113 Mix I.D. No.: 9349 Plant: 16 Field Test Data Test Result Slump, inches: 5.50 Air Content, %: 1.3 Concrete Temperature,o F: 78 Ambient Temperature, o F: 73 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (scI. inches) 4 1 6.00 28.27 4 2 6.00 28.27 Ticket No: 613004 Sample Information Sample Time: 7:05am Date Cast:April 16, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 300 Placement Method: Pump Sample Locations: 8.4, A.7 Placement Location: See page 1 Specification Date Tested 04/23~2002 04/23/2002 Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 4 3 6.00 28.27 05/14/2002 4 4 6.00 28.27 05/14/2002 Age at Maximum Compressive Test Load StrenClth (days) (lbs) 7 118,320 4,180 7 119,300 4,220 Average 4,200 28 137,330 4,860 28 144,330 5,100 Average 4,980 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician:Marvin Arandia Report Distribution: (1) Trensweatem Commercial Se~ices (1) O'Brien & Associates Inc (1) TechniStmctures Inc (1) city of coppa# - Constr ]esp (1) City of Coppell- Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC Engi,~l.~ Eugene Hatbeur Pdncipal The tests were perfonmed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced excep~ in full without the written approval of Tenacon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of e(her apparently similar or identical materials. Page 4 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter FnW., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. ~;} Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: 5:47am Plant: 16 Supplier: Potter Track No: 107 Mix I.D. No.: 9337 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Ticket No: 613605 Sample Information Sample Time: 6:20am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 60 Placement Method: Pump Sample Locations: Panel 75 Placement Location: Panels 53-77 (95A-C) 96 Result _Specification Test Method 4.50 ASTM C-143 1.7 ASTM C-231 83 ASTM C1064 75 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (ps~ 1 1 6.00 28.27 05/10/2002 3 91,870 3,250 1 2 6.00 28.27 05/14/2002 7 108,890 3,850 1 3 6.00 28.27 05/14/2002 7 115,330 4,080 Average 3,970 1 4 06/04/2002 28 1 5 06/04/2002 28 Services - Obtain samples of fresh concrete at the placement locations, pe~orrn required field tests and cast compressive strength samples. The tests were perforated in general accordance with appr~de ASTM, AASHTO, or DOT test merle:Is. This relxxt is e~clusively for the use of the disnt indicated above and shall nct be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 Client: Transwestem Commemial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Fnvy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: 6:57am Plant: 16 Supplier: Potter Truck No: 108 Mix I.D. No.: 9337. Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.75 1.5 80 75 Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 1 2 2 2 3 2 4 2 5 Ticket No: 613616 Sample Information Sample Time: 7:10am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 1703 Placement Method: Pump Sample Locations: Panel 71 Placement Location: See page 1 Specification Test Method 6.00 28.27 05/10~2002 6.00 28.27 05/14/2002 6.00 28.27 05/14/2002 ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 3 93,960 3,320 7 107,.190 3,790 7 105,040 3,710 Average 3,750 06/04/2002 28 06/04/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance wffh applicable ASTM, AASHTO, or DOT test meilxxls. This report is exclusively for the use of the clisrff indicated above and shall not be reproduced excep~ in full without the written approval of Terreco~. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other appemnfly similar or identical materials. Page 2 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 Client: Transwestem Commemial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. ~;~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 7:03am Plant: 16 Supplier: Potter Truck No: 104 Mix I.D. No.: 9337 Field Test Data Test Result Slump, inches: 6.00 Air Content, %: 1.9 Concrete Temperature,o F: 82 Ambient Temperature, o F: 76 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 3 1 6.00 28.27 3 2 6.00 28.27 3 3 6.00 28.27 3 4 3 5 Ticket No: 613622 Sample Information Sample Time: 8:00am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 230 Placement Method: Pump Sample Locations: Panel 68 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 05/10/2002 3 77,200 2,730 05/14/2002 7 93,500 3,310 05/14/2002 7 99,570 3,520 Average 3,420 06/04/2002 28 06/04/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were perfowned in general accordance with applicable ASTM, AASHTO, er DOT test methods. This repod is exclusively f(x the use of the client indicated above and shall not be reproduced excep{ in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar o~ identical materials. Page 3 of 7 ..~w~,~,...., CONCRETE COMPRESSIVE STRENGTH TEST Report NUmber: 94021029.0269 Service Date: May 7, 2002 Client: Transwestem Commemial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 63O-lOlO Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. ~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 8:00am Plant: 16 Supplier: Potter Truck No: 105 Mix I.D. No.: 9337 Field Test Data Test Result Slump, inches: 5.50 Air Content, %: 1.4 Concrete Temperature, o F: 80 Ambient Temperature, o F: 81 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 4 1 6.00 28.27 4 2 6.00 28.27 4 3 6.00 28.27 4 4 4 5 Ticket No: 613633 Sample Information Sample Time: 8:40am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 230 Placement Method: Pump Sample Locations: Panel 96 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 05/10~2002 3 84,250 2,980 05/14~2002 7 103,580 3,660 05/14~2002 7 104,070 3,680 Average 3,670 06~04/2002 28 06/04/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed In general accordance with applicable ASTM, AASHTO, or DOT test meOxxls. ~ report is exclusively for the ,_ _~-e_ of the client indicated above and shall no~ be reproduced except in full without the written approval of TelTacon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propa~ies of other apparently similar or identical materials. Page 4 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number:. 94021029.0269 Service Date: May 7, 2002 Client: Transwestem Commemial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 6..'.'.'.'.'.'.'.'~ 1010 Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. {~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 8:41am Plant: 16 Supplier: Potter Truck No: 111 Mix I.D. No.: 9337 Field Test Data Test Result Slump, inches: 6.50 Air Content, %: 1.7 Concrete Temperature, o F: 89 Ambient Temperature, o F: 88 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 5 I 6.00 28.27 5 2 6.00 28.27 5 3 6.00 28.27 5 4 5 5 Ticket No: 613641 Sample Information Sample Time: 10:10am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 420 Placement Method: Pump Sample Locations: Panel 60 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (Ib~,) (psi) 05/10/2002 3 79,280 2,800 05/14/2002 7 99,300 3,510 05/14/2002 7 108,540 3,840 Average 3,680 06/04/2002 28 06/04/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were perfon~ed in general accordance with applicable ASTM, AASHTO, or DOT test me~hods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full 'without the written approval of Terracen. Test results transmitted herein are only applical~e to the actual samples tested at the location(s) referenced and are not necessarily indicative of the prope~iss of other apparently similar o~ identical materials. Page 5 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: 9:22am Supplier: Potter Truck No: 107 Mix I.D. No.: 9337 Plant: 16 Field Test Data Test Ticket No: 613648 Sample Information Sample Time: 11:12am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 520 Placement Method: Pump Sample Locations: Panel 56 Placement Location: See page 1 Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit We!ght, pcf: Result Specification Test Method ASTM C-143 1.3 ASTM C-231 84 ASTM C1064 88 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (P~ 6 I 6.00 28.27 05/10/2002 3 88,440 3,130 6 2 6.00 28.27 05/14/2002 7 96,720 3,420 6 3 6.00 28.27 05/14/2002 7 103,400 3,660 Average 3,840 6 4 06/04/2002 28 6 5 06/04/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This relxxt is ex=lusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Tetracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily Indicative of the properties of (Y;her apparently similar or identical materials. Page 6 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 · (214)63O-lOlO Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 10:45am Plant: 16 Supplier: Potter Truck No: 108 Mix I.D. No.: 9337 Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 1.4 Concrete Temperature, o F: 85 Ambient Temperature, o F: 90 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 7 1 6.00 28.27 Ticket No: 618656 Sample Information Sample Time: 12:25pm Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Partly cloudy Accumulative Yards: 600 Placement Method: Pump Sample Locations: Panel 63 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Date Tested 05/10/2002 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 3 77,340 2,730 7 2 6.00 28.27 05/14/2002 7 92,100 3,260 7 3 6.00 28.27 05/14/2002 7 88,180 3,120 Average 3,190 7 4 06/04/2002 28 7 5 06/04/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestem Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp (1) Hill & Willdnson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC ~F~ring Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repo~ is exclusively for the use of the client indicated above and shall nct be reproduced except in full without the written approval of Terrecon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of cther apparently similar or identical materials. Page 7 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number.- 94021029.0218 Service Date: April 16, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 =~,.~ 8901 Carpenter FR., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 16, 2002 Project: Amberpoint Building No. 1 ^mberpoint Bus. Pk. ~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: 9:12am Supplier: Potter Truck No: 101 Mix I.D. No.: 9337 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.50 76 70 Ticket No: 613010 Sample Information Sample Time: 9:28am Date Cast:April 16, 2002 Technician: Gerry Graham Weather Conditions:?air, cloudy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: B.2/11 and B/10.8 Placement Location: Piers Specification Test Method 5-7 ASTM C-143 N/A ASTM C1064 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 04~23/2002 1 2 6.00 28.27 04/23/2002 1 3 6.00 28.27 05/14/2002 1 4 6.00 28.27 05/14/2002 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 118,180 4,180 7 116,530 4,120 Average 4,180 28 150,390 5,320 28 153,470 5,430 Average 8,380 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Gerry Graham Report Distribution: (!) Transwsatem Commercial Sm (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp (1) Hill 8, Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC En~ Eugene Harixxlr Principal The tests were performed in general accordance with applicabte ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall ne~ be reprcduced excepl in full without the written approval of Te~racon. Tast rasults transmitted herein are only apfliicable to the actual samples tested at the location(s) referenced and are no~ necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 REPORT OF DRILLED BELLED PIER OBSERVATION Report Number: 94021029.0246 Service Date: April 25, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 89Ol carpenter Fnay., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: May 16, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Services: Drilled belled pier observation. On this date, an HBC Engineering technician arrived at the above referenced jobsite as scheduled for ddlled belled pier observation. See the attached sheet(s) for recorded data. Technician: Gerry Graham Report Distribution: (1) Transwestem Commercial Services (1) O'Brien & Associates thc (1) TechniStructures inc (1) City of Cppl~l - Conatr Insp (1) City of Cpppell - Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Asaociates (1) State Farm Insurance Reviewed by: HBC En~n~ Eugene Harbour Princll~l The t__,~__ were performed in general accordance with applicable ASTM, AASHTO, or DOT test mefl~ds. This report is exclusively for the use of the client indicated above and shall not be reproduced excepl in full without the written approval of Termcon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) mferencad and am not necessarily indicative of the properties of other apparently similar or identical materials, Page 1 of 1 ~s~,~, r~ Iii iii iii iii iii