Deforest Court-LR020530CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021181.0005 Service Date: May 20, 2002 Client: The Holmes Builders Attn: Terry Holmes 1406 Halsey Way Suite 100 Carrollton TX 75007 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 2:00pm Supplier: Redi-Mix Truck No: 127 Mix I.D. No.: 914MR Plant: 1 Field Test Data Test Result Slump, inches: 3.00 Air Content, %: Concrete Temperature, o F: 69 Ambient Temperature, o F: 72 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter No. ID Ticket No: 18208 8901 Carpenter Fnvy., Suite #100 DallasL Texas 75247 /o~ ,~ R~0-1010 Pro. jeLl. DeForest Court Lot #5 ~'~' Single Family Home Coppell, S-~-~--~Io Information Sample Time: 3:1 Opm Date Cast: May 20, 2002 Technician: Phil Green Weather Conditions: Clear, warm Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Pier#18 Placement Location: Piers Specification 5-7 N/A Area Date (inches) (sq. inches) Tested Test Method ASTM C-143 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 1 1 6.00 28.27 05/27/2002 7 88,170 3,120 I 2 6.00 28.27 05/27/2002 7 92,470 3,270 Average 3,200 1 3 06/17/2002 28 1 4 06/17/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Phil Green Re'vi!ed ~~a~l~ Report Distribution: H~ring (1) The Holmes Builders (1) City of Coppell - Constr Insp , ~ (1) City of Coppell- Bldg Insp Huss~i~d~H. Abusaad, P.E Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in fu~l without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 ~w~o~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021181.0007 Service Date: May 21,2002 8901 Carpenter FnNy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: The Holmes Builders Attn: Terry Holmes 1406 Halsey Way Suite 100 Carrollton TX 75007 Report Date: May 30, 2002 Project: 615 DeForest Court Lot #5 Single Family Home Coppell, Texas Project Number: 94021181 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 1:03pm Supplier: Redi-Mix Truck No: 103 Mix I.D. No.: 914MR Water Added Onsite Before Test: 10 Gallons Field Test Data Test Result Slump, inches: 5.00 Air Content, %: Concrete Temperature, o F: 80 Ambient Temperature, o F: 85 Plastic Unit Weight, pcf: Plant: 91 Ticket No: 157700 Sample Information Sample Time: 1:50pm Technician: Robert Sneed Weather Conditions: Accumulative Yards: 10 Placement Method: Chute Sample Locations: See placement location Placement Location: Piers Specification Test Method 5.0 Max ASTM C-143 N/A ASTM C1064 ASTM C-1064 Date Cast: May 21,2002 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) I 1 6.00 28.27 05/28/2002 7 79,170 1 2 6.00 28.27 05/28/2002 7 78,280 Average I 3 06/18/2002 28 1 4 06/18~2002 28 Maximum Compressive Load Strength (lbs) (psi) 2,800 2,770 2,790 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Robert Sneed Report Distribution: (1) The Holmes Builders (1) City of Coppell - Constr Insp (1) City of Coppell- Bldg Insp Reviewed by: HBC Engineering H~usaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021148,0008 Service Date: April 30, 2002 ENGINEEI~NG 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: The Holmes Builders Attn: Jon Dostert/Dean Trudell 1406 Halsey Way Suite 100 Carmllton TX 75007 Report Date: May 30, 2002 Project: 616 DeForest Court Single Family Home Coppell, Texas Project Number: 94021148 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 11:20am Supplier: Redi-Mix Truck No: 273 Mix I.D. No.: 914MR Plant: 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 17684 Sample Information Sample Time: 12:00pm Date Cast:April 30, 2002 Technician: Steve Campbell Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Pier 14 Placement Location: Piers 12, 14, 18, 22 & 28 Result Specification Test Method 6.00 5-7 ASTM C-143 None 93 ASTM C1064 84 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 05/07/2002 7 64,870 2,290 I 2 6.00 28.27 05/07/2002 7 67,500 2,390 Average 2,340 I 3 6.00 28.27 05/28/2002 28 100,880 3,570 I 4 6.00 28.27 05/28/2002 28 99,860 3,530 Average 3,550 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Steve Campbell Report Distribution: (1) The Holmes Builders (1) City of Coppell - Constr Insp (1) City of Coppell - 81dg Insp Reviewed by: ineering Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test resuits transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 o, s~o,~,,~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021148.0010 Service Date: May 1,2002 8901 Carpenter Fnt~y., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: The Holmes Builders Arm: Jon DostedJDean Trudell 1406 Halsey Way Suite 100 Carrollton TX 75007 Report Date: May 30, 2002 Project: 616 DeForest Cou[t Single Family Home Coppell, Texas Project Number: 94021148 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 9:33am Plant: 1 Supplier: Redi-Mix Truck No: 203 Mix I.D. No.: 914MR Field Test Data Test Ticket No: 17728 Sample Information Sample Time: 10:45am Date Cast: May 1, 2002 Technician: Steve Campbell Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Pier 23 Placement Location: Piers 19, 23, 30, 38, 39 Result Specification Test Method Slump, inches: 6.00 5-7 ASTM C-143 Air Content, %: N/A Concrete Temperature,o F: 88 ASTM C1064 Ambient Temperature, o F: 84 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 05/08/2002 7 65,270 2,310 1 2 6.00 28.27 05/08/2002 7 62,930 2,230 Average 2,270 1 3 6.00 28.27 05/29/2002 28 103,230 3,650 1 4 6.00 28.27 05/29/2002 28 103,460 3,660 Average 3,660 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Steve Campbell Report Distribution: (1) The Holmes Builders (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp Reviewed by: H_B.~ngi~neering Hussein H Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repert is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 O~LLW~,F~.~.~