Deforest Court-LR020521CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021129.0015
Service Date: April 22, 2002
ENGINEE PdNG
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Client: The Holmes Builders
Attn: Dennis Ward
1406 Halsey Way Suite 100
Carrollton TX 75007
Report Date: May 21,2002
Project: Single Family Home
632 DeForest Court
Coppell, Texas
Project Number: 94021129
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 5:15pm
Supplier: Redi-Mix
Truck No: 240
Mix I.D. No.: 914MR
Plant: 91
Field Test Data
Test
Ticket No: 156168
Sample Information
sample Time: 7:05pm Date Cast: April 22, 2002
Technician: Phil Green
Weather Conditions: Mostly cloudy
Accumulative Yards: 50
Placement Method: Crane & Bucket
Sample Locations: Pier 59
Placement Location: Piers
Result Specification Test Method
Slump, inches: 3.50 ASTM C-143
Air Content, %: 1.9 ASTM C-231
Concrete Temperature, o F: 78 ASTM C1064
Ambient Temperature, o F: 72 ASTM C-1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at
Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
I I 6.00 28.27 04/29/2002 7 64,840 2,290
1 2 6.00 28.27 04/29/2002 7 61,570 2,180
Average 2,240
I 3 6.00 28.27 05/20/2002 28 86,970 3,080
1 4 6.00 28.27 05/20/2002 28 86,820 3,070
Average 3,080
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Phil Green
Report Distribution:
(1) The Holmes Builders
(1) City of Coppell - Constr Insp
(1) City of Coppell - Bldg Insp
Reviewed by:
HBC Engineering
Hussein I['t.~,b~saad, P.E.
Senior Project Manager