Deforest Court-LR020520CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021129.0012 Service Date: April 19, 2002 Client: The Holmes Builders Attn: Dennis Ward 1406 Halsey Way Suite 100 Carrollton TX 75007 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 3:45pm Supplier: Redi-Mix Truck No: 108 Mix i.D. No.: 914 Plant: 1 Ticket No: 17410 Field Test Data Test Repo~002~ Proj~'ct.' Single Family Hon~ I 632 DeForest C~rt ~k Coppell, ~e~. __ p roj ~..N u m be r,.~vg~]21129 Sam"gfe'llfformation Sample Time: 5:30pm Date Cast:April 19, 2002 Technician: Phil Green Weather Conditions: Overcast Accumulative Yards: 30 Placement Method: Crane & Bucket Sample Locations: Pier #37 Placement Location: Piers Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Result Specification Test Method 3.00 5-7 ASTM C-143 2.2 N/A ASTM C-231 88 ASTM C1064 87 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 8901 Carpenter F~,W., Suite #100 Dallas, Texas 75247 (214) 630-1010 I 1 6.00 28.27 04/26/2002 7 61,870 2,190 1 2 6.00 28.27 04/26/2002 7 63,210 2,240 Average 2,220 1 3 6.00 28.27 05/17/2002 28 94,320 3,340 1 4 6.00 28.27 05/17/2002 28 95,190 3,370 Average 3,360 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Phil Green f , ~'~'~' "~'1~"' Report Distribution: ~ ~ ~'~' ~neering (1) The Holmes Builders Reviewed by: (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp Hussl~in H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 o, LLW~,~,..~.~