Northpoint Dr-LR020531FIELD DENSITY TESTING Report Number: 94021029.0206 Service Date: April 11, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: May 31, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. (~ Coppell Coppell, Texas Project Number: 94021029 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 210290171 ASTM D 698 Reddish dk brown sandy clay (lime treated) Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) 19.2 103.1 -1/+3 95 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) Subgrade Around Pier Caps 302 Grid line I/5 At Grade 1 6 20.6 100.2 97 303 Grid line I/4 At Grade 1 6 21.9 99.1 96 304 Grid line 1/3 At Grade 1 6 21.3 98.6 96 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method;ASTM D2922, ASTM D3017 Gauge ID: Field Results Reported To: Contractor/Brian Technician: Brad Rengstorff Repod Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell - BIdg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC E<~ng Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 oT.s~oT.~.~K~y CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0030 Service Date: May 2, 2002 8901 Carpenter Fn~,y., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: May 31,2002 Proje~: Northpoint Drive & AsSoclat~J Utilities Coppell, Texas Project Number: 94021061 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 10:58am Supplier: Potter Truck No: 107 Mix I.D. No.: 7752 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen No. ID I 1 1 2 Ticket No: 613578 Sample Information Sample Time: 11:50am Date Cast: May 2, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: Canal Wside Placement Location: Canal 1 3 I 4 Result Specification Test Method 5.00 3- 5" ASTM C-143 5.4 4 - 6% ASTM C-231 85 950 ASTM C1064 73 ASTM C-1064 Services - Age at Maximum Compressive Diameter Area Date Test Load Strength (inches) (sq. inches) Tested (days) (lbs) (psi) 6.00 28.27 05/09/2002 7 139,920 4,950 6.00 28.27 05/09/2002 7 137,180 4,850 6.00 28127 05/30/2002 6.00 28.27 05/30/2002 Avrage 4,900 163,170 ~ 161,700 rage 5,750 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestern Commercial Services (1) Glenn Thurman Inc (1) Halff Associates (1) City of Coppell - BIdg Insp (1) State Farm Insurance (1) Moss Construction Reviewed by: HBC Engi,~ Eugene Harbour (1) City of Coppell - Engineering Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full w~thout the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0042 Service Date: May 23, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: May 31,2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 ENGINF~E RINC5 8901 Carpenter Fn,w., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2328 Plant: I Ticket No: Sample Information Sample Time: 8:10am Date Cast: May 23, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 150 Placement Method: Direct Discharge Sample Locations: N Point Rd, Sta. 24+60 Placement Location: Pavement- S of Sandy Lake Road Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 4.0 Concrete Temperature, o F: 67 Ambient Temperature, o F: 80 Plastic Unit Weight, pcf: 148.0 Laboratory Test Data Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 05/30/2002 7 97,990 3,470 I 2 6.00 28.27 05/30/2002 7 94,750 3,350 Average 3,410 I 3 06/20/2002 28 1 4 06/20/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0042 Service Date: May 23, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: May 31,2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2328 Plant: 1 Ticket No: Sample Information Sample Time: 9:10am Date Cast: May 23, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 300 Placement Method: Direct Discharge Sample Locations: N Point Road, Sta. 26+50 Placement Location: See page 1 Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 4.6 Concrete Temperature,° F: 80 Ambient Temperature, o F: 71 Plastic Unit Weight, pcf: 148.8 Laboratory Test Data set Specimen Diameter Area No. ID (inches) (sq. inches) Specification Test Method ASTM C-143 ASTM C-231 ASTM Cl 064 ASTM C-1064 Age at Date Test Tested (days) 2 1 6.00 28.27 05/30/2002 7 2 2 6.00 28.27 05/30~2002 7 Average 2 3 06/20/2002 28 2 4 06/20/2002 28 Maximum Compressive Load Strength (lbs) (psi) 112,730 3,990 109,330 3,870 3,930 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0042 Service Date: May 23, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: May 31,2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2328 Plant: 1 Ticket No: Sample Information Sample Time: 10:10am Date Cast: May 23, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 450 Placement Method: Direct Discharge Sample Locations: N Point Road, Sta. 28+20 Placement Location: See page 1 Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 4.6 Concrete Temperature,° F: 80 Ambient Temperature, o F: 72 Plastic Unit Weight, pcf: 148.2 Laboratory Test Data Specification Test Method ASTM C-143 ASTM C-231 ASTM C 1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 05/30/2002 7 92,920 3,290 3 2 6.00 28.27 05/30/2002 7 98,480 3,480 Average 3,390 3 3 06/20/2002 28 3 4 06/20/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestern Commercial Services (1) Glenn Thurman Inc (1) Halff Associates (1) City of Coppell - Bldg Insp (1) State Farm Insurance (1) Moss Construction Reviewed by: HBC En~ Eugene Harbour (1) City of Coppeil - Engineering Principal The tests were performed in general accordance with applicable ASTM, AAS HTO, or DOT test methods. This repert is exclusively for the use of the c~ent indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 3 of 3 COI~CRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0043 Service Date: May 23, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: May 31,2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter FnNy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3600 psi (~ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: 1 Ticket No: Sample Information Sample Time: 11:45am Date Cast: May 23, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 600 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Pavement- SW of Amberpoint Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.25 3.8 80 73 147.0 Set Specimen Diameter Area No. ID (inches) (sq. inches) I 1 6.00 28.27 I 2 6.00 28.27 I 3 6.00 28.27 Sample location: N Point Rd. approach to water tower entrance 1 4 1 5 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 05/28/2002 5 90,660 3,210 05/28/2002 5 97,030 3,430 Average 3,320 05/30/2002 7 112,580 3,980 06/20/2002 28 06/20/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AAS HTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test resutts transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 CO~CRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0043 Service Date: May 23, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: May 31,2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 Material Information Specified Strength: 3600 psi (~ 28 Days Batch Time: Plant: 1 Supplier: GTI Truck No: Ticket No: Mix I.D. No.: 2329 Field Test Data Test Sample Information Sample Time: 3:30pm Date Cast: May 23, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 600 Placement Method: Direct Discharge Sample Locations: N Point Road 1+75 Placement Location: See page I Specification Test Method Result Slump, inches: 5.50 Air Content, %: 3.6 Concrete Temperature,° F: 80 Ambient Temperature,° F: 77 Plastic Unit Weight, pcf: 146.6 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) ASTM C-143 ASTM C-231 ASTM C 1064 ASTM C-1064 ASTM C-138 2 1 6.00 28.27 05/27/2002 4 97,960 3,460 2 2 6.00 28.27 05/30/2002 7 110,830 3,920 2 3 6.00 28.27 05/30/2002 7 107,750 3,810 Average 3,870 2 4 06/20/2002 28 2 5 06/20/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestern Commercial Services (1) Glenn Thurman Inc (1) Halff Associates (1) City of Coppell - Engineering (1) City of Coppell- Bldg Insp (1) State Farm Insurance (1) Moss Construction Reviewed by_.' HBC En~g Eugene Harbour Pdncipal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the cr~e~ indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2