ST0001-LR020517RoneEr gineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630=9745 (214) 630-9819 (fax) IN-PLACE DENSITY TESTING Client: City of Coppell Arm: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 149875 Project No.: 015729 Date of Service: 05/15/2002 Report Date: 05/17/2002 Project: Services: Creekview Drive and Freeport Parkway Coppell, TX Perform In-Place Density Test in accordance with ASTM Standards. PRO~IECT DATA CONTRACTOR: Test Methods: Infrastructure Services, Inc. ASTM D-2922 ASTM D-3017 M/D No. Standard Counts Description Gauge: Troxler-3430 Moisture Gauge Serial No: 32685 Current: 649 Test Mode: DT Previous: 640 MOISTURE DENSITY RELATIONS Maximum Recycled Concrete Material Density Current: 3086 Previous: 2991 Moisture % Density pcf Project Requirements Moisture Density 16.5 111.0 Optimum +5 95 mia FIELD DENSITY TESTS TEST NO TEST LOCATION PROBE DEPTH M/D MOISTURE WET DENSITY DRY DENSITY DENSITY No. (%) (pet) (pet) (% max) Subgrade brick paving 1 Apex #2, grade Subgrade brick paving 2 Apex #3, grade Subgrade brick paving 3 Apex #4, grade 6" 1 17.3 129.1 6" 1 17.6 130.2 6" 1 18.0 129.9 Test results on this report meet project specification. Technician: Joe Jemigan Started: 5:00pm Finished: 7:00pm Ro__/_/ Report Distribution: (l) City of Coppcll (1) City of Coppell (1) City of Coppell (1) Schfickel, Rollins & Assoc., Inc. ~ ( 1 ) City of Coppell Pro (I) Infrastructure Services, Inc. · 110.1 9~1~09 110.7 110.1 ~9 , Stark Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 07CM Page 1 of 1 "oneEn gil 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Arm: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 149516 Project No.: 015729 Date of Service: 05/09/2002 Report Date: 05/17/2002 Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of flesh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laborato~T for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimor¢ PLANT: 7 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 38 PLACEMENT DATE: 05/09/2002 WEATHER CONDITIONS: Cloudy TIME SAMPLED: l:00pm EATCHT~ME: 12:26pm TEMPEKATURE(F)-AIR 65 r CONCRETE: 90 v X~UCK NO: 1040 TIC~T NO: 7116441 AIR CONTENT (%): 4.5 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Light pole on the median of State Street, turning into the west parking lot SAMPLE LOCATION: REPORT OF TESTS 30' south from the apex of median of State Street, light pole Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 1 1 4.0 1 2 4.0 I 3 4.0 1 4 Technician: Antholly Maldonado Report Distribution: (1) City of Copp¢I1 (1) City of Coppell (1) City of Coppell (1) Infrastructure Services, Inc. MAXIMUM DATE AGE LOAD TESTED (days) 0b~ force) 05/16/2002 7 94345 COMPRESSIVE STRENGTH FRACTURE (psi) TYPE 3340 Unbonded Cap 06/06/2002 28 06/06/2002 28 Hold Started: 12:30pm Finished: 2:00pm (1) City of Coppell (I) Schrickel, Rollins & Assoc., Inc. Unbonded Cap Unbonded Cap Rone ~/~.ra l~c, LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page I of 1 RoneEn gineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) IN-PLACE DENSITY TESTING Client: Project: Services: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppel! TX 75019 Creekview Drive and Freeport Parkway Coppell, TX Perform In-Place Density Test in accordance with ASTM Standards. Report No.: 149510 Project No.: 015729 Date of Service: 05/09/2002 Report Date: 05/17/2002 CONTRACTOR: Test Methods: Infrastructure Services, Inc. ASTM D-2922 ASTM D-3017 PROJECT DATA Gauge: TroxIer 3430 Gauge Serial No: 32685 Test Mode: DT Moisture Current: 643 Previous: 637 Standard Counts Density Current: 3002 Previous: 2966 M/D No. Description MOISTURE DENSITY RELATIONS Maximum Moisture % Density pcf Dark Brown Clay, trace organics and gravel (Lime treated) 22.5 96.5 Project Requirements Moisture Density Optimum +5 95 min FIEI,D DENSITY TESTS TEST NO PROBE TEST LOCATION DEPTH M/D MOISTURE WET DENSITY DRY DENSITY DENSITY No. (%) (pc/) (pef) (% max) Paving Subgrade Station Road, Station 35+10 6" 1 24.9 Test results on this report meet project specification. Technician: Joe Jemigan Report Distribution: (1) City of Coppell (1) City of Coppell (1) City of Coppell (1) Infrastructure Services, Inc. Started: 12:00p (1) City of Coppell (1) Schrickel. Rollins & Assoc., Inc. 121.2 97.0 101 Finished: l:30pm Ronel Project I LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 07DK Page 1 of 1