Loading...
ST0001-LR020523RoneEn gineers 8908 Ambassador Row Dallas, Texas 75247-4510 (21~) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Atto: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 148410 Project No.: 015729 Date of Service: 04/24/2002 Report Date: 05/23/2002 Creekview Drive and Freeport Park-way Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTEACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore FLAir: 7 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3" - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN LD.: 42 pLAC~ME~rr DATE: 04/24/2002 WEATHER CONDITIONS: Cloudy TIME SAMPLED: 9:00am BATCH TIME: 8:26am TEMPERATURE (F) - Am 75 F CONCRETE: 90 r TRUCK NO: 1125 TICKET NO: 7115787 AIR CONTENT (%): 4.0 UNIT WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: Paving - turn lane of Freeport Parkway to Ruby, eastbound approaches on State and southbound and northbound driveway leading into west parking lot, and apex of median of State & Freeport north & south SAMPLE LOCATION: 5' south x 3' east of northwest REPORT OF TESTS ~om~ of approach at Freeport Concrete Compressive Cylindex 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. 0aches) TESTED (days) Obs. force) (psi) TYPE 1 1 3.0 04/27/2002 3 75455 2670 Unbonded Cap 1 2 3.0 05/01/2002 7 92375 3270 Unbonded Cap 1 3 3.0 05/22/2002 28 117540 4160 Unbonded Cap 1 4 3.0 05/22/2002 28 115120 4070 Unbonded Cap Average 4120 1 5 Hold LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation ia quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 1 of 4 Report No.: 148410 RoneEngineers Project No.: 015729 m~n~l Client: City of Coppell CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH SET NO. (inches) TESTED (days) (lbs. force) (psi) FRACTURE TYPE Water added at site: 10 gallons ***REVISED this date to reflect correct billing time. See report #149798 for overtime*** LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 2 of 4 gineers 8908 Ambnssador Row Dnllas, Texns ?$247-4510 (2i4) 630-9745 (214) 630=9819 (fnx) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Atto: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 148410 Project No.: 015729 Date of Service: 04/24/2002 Report Date: 05/23/2002 Creekview Drive and Freeport Parkway Coppoll, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): A1R (%): TEST METHOD: co~crancroR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days T' - 5" 3% - 6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 42 PLACEMENT DATE: 04/24/2002 WEATHER CONDITIONS: Cloudy TIME SAMPLED: 1:05pm CATCH TIM~: 12:36pm TEMPERATURE (F) - AIR 78 F CONCRETE: 90 F TRUC~ NO: 975 TlC~T NO: 3143682 AIR CONTENT (%): 4,5 UNIT WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: Paving - turn lane of Freeport Parkway to Ruby eastbound approaclunents on State and southbound and notthbound driveway leading into west parking lot and noses of mediun State & Freeport north & south SAMPLE LOCATION: 10' north x 8' east of southwest REPORT OF TESTS comer of veway west p=king lot Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) Obs. force) (psi) TYPE 2 1 3.25 04/27/2002 3 80130 2830 Unbonded Cap 2 2 3.25 05/01/2002 7 89780 3170 Unbonded Cap 2 3 3.25 05/22/2002 28 ! 15525 4090 Unbonded Cap 2 4 3.25 05/22/2002 28 112720 3990 Unbonded Cap Average 4040 2 5 Hold LIMITATIONS: The test results presented heroin were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditiom over which we have no control. Our letters and reports are for the exclusive usc of thc clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 3 of 4 Report No.: 148410 RoneEngineers Project No.: 015729 Im'ltnl*~ 1 Client: City of Coppell CYLINDER MEASURED MARKED SLUMP SET NO. (inches) DATE AGE TESTED (days) MAXIMUM COMPRESSIVE LOAD STRENGTH FRACTURE Obs. force) (psi) TYPE Technician: Anthony Maldonado Report Distribution: (1) City of Coppell (1) City of Coppell (1) City of Coppell (1) Infras~ucture Services, Inc. Started: 7:30am Finished: 3:30pm (1) City of Coppell (1) Schrickcl, Rollins & Assoc., Inc. Rone ~ LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 4 of 4