ST0001-LR020528RoneEn gin 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 148631 Project No.: 015729 Date of Service: 04/26/2002 Report Date: 05/28/2002 Creek'view Drive and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 3 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 38 PLACEMENT OATE: 04/26/2002 WEATHER CONDITIONS: Cloudy TIME SAMPLED: 3:30pm BATCH TIME: 2:42pm TEMPERATURE (F) - AIR 70 F CONCRETE: 80 F T~UCK NO: 1124 TIC~r~T NO: 3143829 AIR CONTENT (%): 4.0 UNIT WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: Inlets - Creekview, south lane, Station 25+88, Station 25+50, Station 25+00 and Station 24+50 SAMPLE LOCATION: REPORT OF TESTS Station 25+00, south lane of Creekview Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP SET NO. (inches) I 1 3.0 DATE TESTED 05/03/2002 MAXIMUM COMPRESSIVE AGE LOAD STRENGTH FRACTURE (days) (lbs. force) (psi) TYPE 7 93260 3300 Unbonded Cap 1 2 3.0 1 3 3.0 05/24/2002 05/24/2002 28 118210 4180 Unbonded Cap 28 115150 4070 Unbonded Cap Average 4130 1 4 Water added at s±te: 5 Technician: Anthony Maldonado Report Distribution: (1) City of Coppell (1) City of Coppell (1) City of Coppell (1) Infrastructure Services, Inc. Hold ~allons Started: l:00pm Finished: 4:30pm (1) City of Coppell (1) Sehrickel, Rollins & Assoc., Inc. Rone ~ Cla~ Stark' LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, pe'rformancc, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom thc,/are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 1 of 1