ST0001-LR020529RoneEngineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630=9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 148749 Project No.: 015729 Date of Service: 04/29/2002 Report Date: 05/29/2002 Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONT~croR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore P~ANT: 03 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DES1GN I.D.: 38 PLACEMENT DATE: 04/29/2002 WEATHER CONDITIONS: Cloudy TIME SAMPLED: 3:10pm EATC~ITIM~: 2:33pm TEMPERATURE (F) - AIR 88 F CONCRETE: 80 F TmJOC NO: 1050 TICI~T NO: 3143880 AIR CONTENT (%): 4.2 UNITWEIGHT(pcf): NA OVERALL PLACEMENT LOCATION: Inlets - eastbound lane of Creekvinw at Station 3+50 and Station 4+00, Station 25+00 and Station 25+88 and Station 21+00 and Stafmn 22+00 SAMPLE LOCATION: Same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) Obs. force) (psi) TYPE 1 1 3.75 05/02/2002 3 76350 2700 Unbonded Cap 1 2 3.75 05/06/2002 7 85070 3010 Unbonded Cap 1 3 3.75 05/27/2002 28 105675 3740 Unbonded Cap 1 4 3.75 05/27/2002 28 107805 3810 Unbonded Cap Average 3780 1 5 Hold LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subjec! matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 1 of 2 Report No.: 148749 RoneEngineers Project No.: 015729 Client: City of CoPpell [ll~l~l~l CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE Concrete scheduled for 2:30pm truck arrived at 3:00pm R°necl~ay~~ Technician: Ben Weaverling Report Distribution: (1) City of Coppell (1) City of Coppell (1) City of Coppell (l) Infrastructure Services, Inc. Started: 2:00pm Finished: 5:00pm (1) City of Coppell (1) Schrickel, Rollins & Assoc., Inc. Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 2 of 2 8908 Ambassador Row Dallas, Te~ns (~14) 630=9~19 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 150121 Project No.: 015729 Date of Service: 05/20/2002 Report Date: 05/29/2002 Creekxdew DHve and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field te~ting, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: TXI PLANT: 41 SPECIFICATION REQUIREMENTS 4000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 9982 PLACEMENT DATE: 05/20/2002 WEATHER CONDITIONS: Clear TIME SAMPLED: 12:40pm BATCHT1ME: ll:47am TEMPERATURE OF) - AIR 70 F CONCRETE: 90 F TRUCK NO: 71 TICKET NO: 3133134 AIR CONTENT (%): 4.0 UNIT WEIGHT (pet): NA OVERALL PLACEMENT LOCATION: Paving stamped concrete east approachmcnt into Wagon Wheel Baseball Park, west parking lot SAMPLE LOCATION: 10' north x 3' east of southwest REPORT OF TESTS comer of paving, east approachmant Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 2.5 05/23/2002 3 117170 4140 Unbonded Cap 1 2 2.5 05/27/2002 7 144920 5120 Unbonded Cap 1 3 2.5 06/17/2002 28 Unbonded Cap 1 4 2.5 06/17/2002 28 Unbonded Cap 1 5 Hold LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 1 of 2 Report No.: 150121 R°neEngineers Project No.: 015729 .......... ~l CHent: City of Coppell Water added at site: 10 gallons Technician: Anthony Maldonado Report Distrlbution: (1) City of Coppell (1) City of Coppell (1} City of Coppell (1) Infia.saamture Services, Inc. Started: 11:30am (1) City of Coppell (1) Sehrickel, Rollins & Assoc., Inc. Finished: h30pm LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject mat~er provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 2 of 2 gineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Project: ~Creekview Drive and FreepoTt Parkway Coppe[1, TX Services: Report No.: 150205 Project No.: 015729 Date of Service: 05/21/2002 Report Date: 05/29/2002 Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 MIX DESIGN I.D.: 115702 PLACEMENT DATE: 05/21/2002 WEATHER CONDITIONS: Sunny TIME SAMPLED: 2:00pm BATCH TIME: 12:27pm TEMPERATURE (F) - AIR 85 F CONCRETE: 85 F TRUCK NO: 1045 TICKET NO: 16249 AIR CONTENT (%): 3.4 UNIT WEIGHT (PC0: NA OVERALL PLACEMENT LOCATION: Creekview retaining wall footing SAMPLE LOCATION: South side of street at Station 0+50, 5' offcurb ASTM C-39 RF, PORT Og TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 3.0 05/28/2002 13.0 06/18/2002 ~ 06/18/2002 Hold Water added at site: 10 gallons Technician: Simon Gibbons Report Distribution: (1) City of Coppell (1) City of Coppell (1) City of Coppell (1) Infrasn'ueture Services, Inc. Started: (1) City of Coppell (1) Sehriekel, Rollins & Assoc., Inc. 7 95160 ~i~/0 Unbonded Cap Unbonded Cap 12:30pm Finished: 4:00pm ' Rone ' C~y ~tark Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our leuers and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, lnc. 01DK Page I of 1