Amberpoint BP-LR020610CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0276 Service Date: May 11,2002 Lq~g~INI~EI~JNG 8901 Carpenter Rwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 10, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 7:30am Supplier: Potter Truck No: 115 Mix I.D. No.: 9337 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Ticket No: 613718 Sample Information Sample Time: 7:50am Date Cast: May 11,2002 Technician: Brad Rengstorff Weather Conditions: Cloudy Accumulative Yards: 50 Placement Method: Pump Sample Locations: Panel #50 Placement Location: Panels- 39-52, 91, SW1-SW8, Panel 92A, B,C Result Specification Test Method 5.25 4-6 ASTM C-143 1.6 N/A ASTM C-231 83 ASTM Cl 064 72 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 I 6.00 28.27 05/14/2002 3 g8,970 3,500 I 2 6.00 28.27 05/18/2002 7 124,160 4,390 I 3 6.00 28.27 05/18/2002 7 123,860 4,380 Average 4,390 1 4 6.00 28.27 06/08/2002 28 147,250 5,210 1 5 6.00 28.27 06/08/2002 28 148,220 5,240 Average 5,230 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the usa of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5 o~ L~w~,,, K,~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0278 Service Date: May 11, 2002 I~"N(~NEEI~NCl 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 10, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 8:25am Plant: 16 Supplier: Potter Truck No: 115 Mix I.D. No.: 9337 Ticket No: 613727 Sample Information sample Time: 8:35am Date Cast: May 11, 2002 Technician: Brad Rengstorff Weather Conditions: Cloudy Accumulative Yards: 50 Placement Method: Pump Sample Locations: Panel 42 Placement Location: Panel 39-43, 46-52, 91, 92, A, B, C, SW1 -SW8 Field Test Data Test Result Specification Test Method Slump, inches: 5.50 4-6 ASTM C-143 Air Content, %: 1.7 N/A ASTM C-231 Concrete Temperature,o F: 83 ASTM C1064 Ambient Temperature, o F: 73 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 I 6.00 28.27 05/14/2002 3 93,650 3,310 2 2 6.00 28.27 05/18/2002 7 120,290 4,250 2 3 6.00 28.27 05/18/2002 7 115,500 4,080 Average 4,170 2 4 6.00 28:27 06/08/2002 28 153,450 5,430 2 5 6.00 28.27 06/08/2002 28 144,460 5,110 Average 5,270 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and ara not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5 ~<Lw~o~o ~.~ 'CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0276 Service Date: May 11, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 10, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 9:43am Plant: 16 Supplier: Potter Truck No: 103 Ticket No: 613738 Mix I.D. No.: 9337 Sample Information Sample Time: 10:20am Date Cast: May 11, 2002 Technician: Brad Rengstorff Weather Conditions: Cloudy Accumulative Yards: 250 Placement Method: Pump Sample Locations: Panel #39 Placement Location: Panel 39-43, 46-52, 91,92, A, B, C, SW1-SW8 Field Test Data Test Result Specification Test Method Slump, inches: 5.00 4-6 ASTM C-143 Air Content, %: 1.3 N/A ASTM C-231 Concrete Temperature, o F: 83 ASTM Cl 064 Ambient Temperature, o F: 74 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 05/14/2002 3 108,950 3,850 3 2 6.00 28.27 05/18/2002 7 125,360 4,430 3 3 6.00 28.27 05/18/2002 7 130,640 4,620 Average 4,530 3 4 6.00 28.27 06/08/2002 28 152,580 5,400 3 5 6.00 28.27 06/08/2002 28 151,090 5,340 Average 5,370 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the usa of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5 'CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0276 Service Date: May 11,2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 10, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 10:30am Supplier: Potter Truck No: 115 'Mix I.D. No.: 9337 Plant: 16 Field Test Data Test Result Slump, inches: 4.75 Air Content, %: 1.2 Concrete Temperature, o F: 84 Ambient Temperature, o F: 79 Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 613746 Sample Information Sample Time: 11:15am Date Cast: May 11,2002 Technician: Brad Rengstorff Weather Conditions: Cloudy Accumulative Yards: 330 Placement Method: Pump Sample Locations: Panel 92B Placement Location: Panel 39-43, 46-52, 91, 92, A, B, C, SW1-SW8 Specification Test Method 4-6 ASTM C-143 N/A ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 1 6.00 28.27 05/14/2002 3 94,610 3,350 4 2 6.00 28.27 05/18/2002 7 116,840 4,130 4 3 6.00 28.27 05/18/2002 7 120,900 4,280 Average 4,210 4 4 6.00 28.27 06/08/2002 28 139,580 4,940 4 5 6.00 28.27 06/08/2002 28 143,280 5,070 Average 5,01.0 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted heroin are only applicable to the actual samples tested at the location(s) roferonced and ara not necessarily indicative of the properties of other apparontly similar or identical materials. Page 4 of 5 o~w~,~a,,~,~ 'CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0276 Service Date: May 11,2002 E. NGINF~EI~ING 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630~1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 10, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 11:37am Supplier: Potter Truck No: 102 Mix I.D. No.: 9337 Plant: 16 Field Test Data Test Result Slump, inches: 5.50 Air Content, %: 1.4 Concrete Temperature,o F: 86 Ambient Temperature, o F: 82 Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 613758 Sample Information Sample Time: 12:20pm Date Cast: May 11,2002 Technician: Brad Rengstorff Weather Conditions: Clear Accumulative Yards: 450 Placement Method: Pump Sample Locations: Panel SW7 Placement Location: Panel 39-43, 46-52, 91, 92, A, B, C, SW1-SW8 Specification Test Method 4-6 ASTM C-143 N/A ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 5 1 6.00 28.27 05/14/2002 3 90,300 3,190 5 2 6.00 28.27 05/18/2002 7 114,930 4,060 5 3 6.00 28.27 05/18/2002 7 112,870 3,990 Average 4,030 5 4 6.00 28.27 06/08/2002 28 . 132,260 4,680 5 5 6.00 28.27 06/08/2002 28 133,840 4,730 Average 4,710 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Brad Rengstorff Report Distribution: (1) Transwestem Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell - BIdg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC En~ng Eugene Harbour Principal The tests w~re performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the usa of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and ara not necessarily indicative of the properties or other apparently similar or identical materials. Page 5 of 5 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0292 Service Date: May 31,2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 ,~p r ~Ba~~~ll~el, Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 10:41am Plant: 16 Supplier: Potter Concrete Truck No: 106 Mix I.D. No.: 9337 Ticket No: 613917 Sample Information Sample Time: 10:55am Technician: Eric Garcia Weather Conditions: Accumulative Yards: 15 Placement Method: Pump Sample Locations: Date Cast: May 31,2002 Top left of grade beams @ B.9/0-1 Field Test Data Test Result Slump, inches: 5.00 Air Content, %: Concrete Temperature,o F: 85 Ambient Temperature, o F: 88 Plastic Unit Weight, pcf: Laboratory Test Data set Specimen Diameter Area No. ID (inches) (sq. inches) I I 6.00 28.27 1 2 6.00 28.27 I 3 I 4 Placement Location: Grade beams @ B.9-0.1 and M.7/0-1; 3 columns @ B.6 Line and 2 columns @ N line (N/l, N.6/1) Specification Test Method ASTM C-143 ASTM C1064 ASTM C-1064 Date Tested 06/07/2002 06/07/2002 06/28/2002 06/28~2002 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 100,230 3,540 7 96,420 3,410 Average 3,480 28 28 1 5 07~26/2002 56 Services - strength samples. Technician: Eric Garcia Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp Obtain samples of fresh concrete at the placement locations, perform required field tests and cast com[~res~jve . Reviewed by: (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance HBC Engin~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1