Amberpoint BP-LR020604CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 8901 Carpenter FnNy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 04, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 5:47am Plant: 16 Supplier: Potter Truck No: 107 Mix I.D. No.: 9337 Ticket No: 613605 Sample Information sample Time: 6:20am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 60 Placement Method: Pump Sample Locations: Panel 75 Placement Location: Panels 53-77 (95A-C) 96 Field Test Data Test Result Specification Test Method Slump, inches: 4.50 ASTM C-143 Air Content, %: 1.7 ASTM C-231 Concrete Temperature,° F: 83 ASTM C1064 Ambient Temperature, o F: 75 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) I 1 6.00 28.27 05/10/2002 3 91,870 3,250 1 2 6.00 28.27 05/14/2002 7 108,890 3,850 I 3 6.00 28.27 05/14/2002 7 115,330 4,080 Average 3,970 1 4 6.00 28.27 06/04/2002 28 144,960 5,130 1 5 6.00 28.27 06/04/2002 28 146,980 5,200 Average 5,170 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is excl~ for Ihe usa of the ~ indicated above and shall not be reproduced except in full without the written approval of Terracon, Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 04, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 6:57am Plant: 16 Supplier: Potter Truck No: 108 Mix I.D. No.: 9337 Ticket No: 613616 Sample Information Sample Time: 7:10am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 1703 Placement Method: Pump Sample Locations: Panel 71 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.75 ASTM C-143 Air Content, %: 1.5 ASTM C-231 Concrete Temperature, o F: 80 ASTM C1064 Ambient Temperature, o F: 75 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID . (inches) (sq. inches) Tested (days) (lbs) (psi) 2 I 6.00 28.27 05/10~2002 3 93,960 3,320 2 2 6.00 28.27 05/14/2002 7 107,190 3,790 2 3 6.00 28.27 05/14/2002 7 105,040 3,710 Average 3,750 2 4 6.00 28.27 06/04/2002 28 142,300 5,030 2 5 6.00 28.27 06/04/2002 28 140,180 4,960 Average 5,000 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were pedormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the ~ indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 04, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 7:03am Plant: 16 Supplier: Potter Truck No: 104 Mix I.D. No.: 9337 Field Test Data Test Result Slump, inches: 6.00 Air Content, %: 1.9 Concrete Temperature,o F: 82 Ambient Temperature, o F: 76 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 3 1 6.00 28.27 3 2 6.00 28.27 3 3 6.00 28.27 3 4 6.00 28.27 3 5 6.00 28.27 Ticket No: 613622 Sample Information Sample Time: 8:00am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 230 Placement Method: Pump Sample Locations: Panel 68 Placement Location: See page I Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C- 1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 05/10/2002 3 77,200 2,730 05/14/2002 7 93,500 3,310 05/14/2002 7 99,570 3,520 Average 3,420 06/04/2002 28 125,160 4,430 06/04/2002 28 129,170 4,570 Average 4,500 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AAS~TO, or DOT test methods. This report is exclusively for the use of the clienl indicated above and shall not bo reproduced except in full without the written approval of Terracon. Test results transmitted herein are only aPlflicable to the actual samples tested at the location(s) referenced and ara not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 7 ~w,.,,-,~.. K~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 04, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 8:00am Plant: 16 Supplier: Potter Truck No: 105 Mix I.D. No.: 9337 Field Test Data Test Ticket No: 613633 Sample Information sample Time: 8:40am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 230 Placement Method: Pump Sample Locations: Panel 96 Placement Location: See page 1 Result Specification Test Method Slump, inches: 5.50 ASTM C-143 Air Content, %: 1.4 ASTM C-231 Concrete Temperature, o F: 80 ASTM C1064 Ambient Temperature, o F: 81 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Stren~h No. ID (inches) (sq. inches) Tested (days) (lbs) (PS0 4 I 6.00 28.27 05/10/2002 3 84,250 2,980 4 2 6.00 28.27 05/14/2002 7 103,580 3,660 4 3 6.00 28.27 05/14/2002 7 104,070 3,680 Average 3,670 4 4 6.00 28.27 06/04/2002 28 139,520 4,930 4 5 6.00 28.27 06/04/2002 28 135,980 4,810 Average 4,870 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of'the cr~ent indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 04, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 8:41am Supplier: Potter Truck No: 111 Mix I.D. No.: 9337 Plant: 16 Field Test Data Test Ticket No: 613641 Sample Information sample Time: 10:10am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 420 Placement Method: Pump Sample Locations: Panel 60 Placement Location: See page 1 Result Specification Test Method Slump, inches: 6.50 ASTM C-143 Air Content, %: 1.7 ASTM C-231 Concrete Temperature,o F: 89 ASTM C1064 Ambient Temperature, o F: 88 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 5 1 6.00 28.27 05/10/2002 3 79,280 2,800 5 2 6.00 28.27 05/14/2002 7 99,300 3,510 5 3 6.00 28.27 05/14/2002 7 108,540 3,840 Average 3,680 5 4 6.00 28.27 0610412002 28 133,100 4,710 5 5 6.00 28.27 06/04/2002 28 129,110 4,570 Average 4,640 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the ~ indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 5 of 7 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spdng Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 04, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 9:22am Plant: 16 Supplier: Potter Truck No: 107 Mix I.D. No.: 9337 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 613648 Sample Information Sample Time: 11:12am Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 520 Placement Method: Pump Sample Locations: Panel 56 Placement Location: See page I Result · Specification Test Method ASTM C-143 1.3 ASTM C-231 84 ASTM C1064 88 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 6 1 6.00 28.27 05/10/2002 3 88,440 3,130 6 2 6.00 28.27 05/14/2002 7 96,720 3,420 6 3 6.00 28.27 05/14/2002 7 103,400 3,660 Average 3,540 6 4 6.00 28.27 06/04/2002 28 130,620 4,620 6 5 6.00 28.27 06/04/2002 28 134,110 4,740 Average 4,680 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 7 o~_Lw~o~.~., CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0269 Service Date: May 7, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 04, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 10:45am Plant: 16 Supplier: Potter Truck No: 108 Mix I.D. No.: 9337 Field Test Data Test Ticket No: 618656 Sample Information Sample Time: 12:25pm Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Partly cloudy Accumulative Yards: 600 Placement Method: Pump Sample Locations: Panel 63 Placement Location: See page I Result Specification Test Method Slump, inches: 5.00 ASTM C-143 Air Content, %: 1.4 ASTM C-231 Concrete Temperature, o F: 85 ASTM Cl 064 Ambient Temperature, o F: 90 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (SCl. inches) Tested (days) (lbs) (psi) 7 I 6.00 28.27 05110/2002 3 77,340 2,730 7 2 6.00 28.27 05/14/2002 7 92,100 3,260 7 3 6.00 28.27 05/14/2002 7 88,180 3,120 Average 3,190 7 4 6.00 28.27 06104/2002 28 118,300 4,180 7 5 6.00 28.27 06/04/2002 28 115,270 4,080 Average 4,130 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC Enginee~ Eugene Harbour P~cipal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively fa' the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only apprmabie to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 7 of 7