Northpoint Dr-LR020607CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0047 Service Date: May 30, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 63o-1 Ol o Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 07, 2002 Project: Northpoint Ddve & Associated Utilities Coppell, Texas Project Number: 94021061 Ma terial In formation Specified Strength: 3000 psi (~ 28 Days Batch Time: 2:21 pm Supplier: LMC Truck No: 964 Mix I.D. No.: 38 Plant: 3 Ticket No: 3145411 Sample Information Sample Time: 3:35pm Date Cast: May 30, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 3 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Manhole inlets Field Test Data Test Result Specification Test Method Slump, inches: 3.00 4.0 Max ASTM C-143 Air Content, %: 1.8 N/A ASTM C-231 Concrete Temperature,o F: 80 ASTM C1064 Ambient Temperature, o F: 88 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) I 1 6.00 28.27 06/06/2002 7 118,740 4,200 1 2 6.00 28.27 06/06/2002 7 125,000 4,420 Average 4,310 1 3 0612712002 28 1 4 06/27/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestsm Commercial Services (1) Glenn Thurman Inc (1) Halff Associates (1) City of Coppell - Engineering (1) City of Coppell - Bldg Insp (1) State Farm Insurance (1) Moss Construction Reviewed by: HBC Eng~ Eugene Harbour Prin~pal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar er identical materials. Page 1 of I CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0046 Service Date: May 30, 2002 8901 Carpenter Fmc., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commemial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 07, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 Material Information Specified Strength: 3600 psi (~ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: 1 Ticket No: Field Test Data Test Result Slump, inches: 6.00 Air Content, %: · 3.6 Concrete Temperature, o F: 80 Ambient Temperature, o F: 78 Plastic Unit Weight, pcf: 147.4 Laboratory Test Data Sample Information Sample Time: 8:50am Date Cast: May 30, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 30 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Approaches- S of Amberpoint Specification Test Method ASTM C.-143 ASTM C-231 ASTM Cl 064 ASTM C-1064 ASTM C-138 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) I I 6.00 28.27 06/06/2002 7 99,520 3,520 I 2 6.00 28.27 06/06/2002 7 97,430 3,450 Average 3,490 1 3 06/27/2002 28 1 4 06/27/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the crmal indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 ~,~.~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0046 Service Date: May 30, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commemial Services Attn: Jim Gaspard 5001 Spdng Valley Rd Suite 600W Dallas TX 75244 Report Date: June 07, 2002 Project: Northpoint Ddve & Associated Utilities Coppell, Texas Project Number: 94021061 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: 1 Ticket No: Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 3.5 Concrete Temperature,o F: 81 Ambient Temperature, o F: 88 Plastic Unit Weight, pcf: 149.0 Laboratory Test Data Sample Information Sample Time: 2:55pm Date Cast: May 30, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 150 Placement Method: Direct Discharge Sample Locations: Sta. southside 0+50 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 06/06/2002 7 110,930 3,920 2 2 6.00 28.27 06/06/2002 7 110,950 3,920 Average 3,920 2 3 06/27/2002 28 2 4 06/27/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestern Commercial Services (1) Glenn Thurman Inc (1) Halff Associates (1) City of Coppell - Engineering (1) City of Coppell- BIdg Insp (1) State Farm Insurance (1) Moss Construction Reviewed by: HBC Engine~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparentJy similar or identical matedals. Page 2 of 2