Northpoint Dr-LR020604CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0033 Service Date: May 7, 2002 8901 Carpenter FTC7.., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 04, 2002 Project: Norlhooint Ddve & - AsSoclateQ Utllltl~5 Coppell, Texas Project Number: 94021061 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 3:02pm Supplier: LMC Truck No: 1124 Mix I.D. No.: 38 Plant: 3 Field Test Data Test Ticket No: 3144346 Sample Information Sample Time: 4:05pm Date Cast: May 7, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 9 Placement Method: Direct Discharge Sample Locations: 0+05.84 Placement Location: Inlets- Sta. 0+42.43, 0+14.4 & 0+05.84 Result Specification Test Method Slump, inches: 3.00 ASTM C-143 Air Content, %: 1.5 ASTM C-231 Concrete Temperature, o F: 88 ASTM Cl 064 Ambient Temperature, o F: 92 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test*Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 I 6.00 28.27 1 2 6.00 28.27 I 3 6.00 28.27 1 4 6.00 28.27 05/14/2002 7 92,120 3,260 05114/2002 7° 94,320 3,340 06/04~200 ,360 06/04/200~ 122,400 ~ Average 4,300 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestern Commercial Services HBC EngiF- (1) City of Coppell - Bldg Insp (1) Glenn Thurman Inc (1) State Farm Insurance Reviewed by.', . (1) Halff Associates (1) Moss Construction Eugene Hal~bour (1) City of Coppell - Engineering Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is ~ for the use of the indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar er idenlical materials. Page 1 of 1