Northpoint Dr-LR020531 (2)FIELD DENSITY TESTING Report Number: 94021061.0039 Service Date: May 17, 2002 8901 Carpenter Fm/y., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: May 31,2002 Project; Northneint Drive & "'-Assoc ated~t~ es Coppell, Texas Project Number: 94021061 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 210610035 ASTM D 698 2. 210610034 ASTM D 698 Field Test Data Test No. Med brown clay (lime treated) Med brown clay (lime treated) Test Location 17.9 104.0 -2/+3 95 25.3 92.1 -2/+3 95 Paving Sta. 27+50 Northpointe Drive 106 107 Sta. 24+50 108 Sta. 21+00 109 Sta. 17+50 110 Sta. 13+00 111 Sra. 10+00 112 Sta. Northpointe Ddve Northpointe Dnve Northpointe Drive Northpointe Drive Northpointe Drive 7+50, Northpointe Drive Probe Water Dry Unit Lift/ Mat. Depth Content Weight Elevation No. (inches) ~ (pct} Final 1 6 ~ 98.9 Final 2 6 91.9 Final 2 6 ~ 90.6 Final 1 6 ~ 99.3 Final 1 6 98.7 Final 2 6 Final 2 6 27.3 89.1 25.9 89.6 4+50, Northpointe Drive Final 1 6 ~ 101.0 1+50, Northpointe Ddve Final 1 6 ~/21.0~ 100.6 appears next to test results which do NOT meet the project specificatio~'~s. Dry Unit Weight (% compaction) 95 100 98 95 95 97 97 113 Sta. 114 Sta. Comments: An asterisk (*) Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method;ASTM D2922, ASTM D3017 Gauge ID: 31787 Technician: Roy Montgomery /"/! Report Distribution: HBC (1) Transwestem Commercial Services (1) City of Coppell- Bldg Insp Reviewed by: (1) Glenn Thurman Inc (1) State Farm Insurance (1) Halff Associates (1) Moss Construction Eugene Harbour. (1) City of Coppell - Eng!neering Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full witbo'ut the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 o~.so~o~,~,~