Loading...
ST0001-LR020607L A :M 8908 Ambassador Row Dallas, Texas 752474510 (214) 630 -9745 (214) 630 -9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Report No.: 149516 Attu: Ms. Susan Taylor - Engineering Dept Project No.: 015729 PO Box 478 Date of Service: 05/09/2002 Coppell TX 75019 Report Date: 06 /07/2 002 /' Creekview Drive and F � Freeport Parkway r Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive a plea at samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi @ 28 Days SLUMP (in): 3 5 AIR (%): 3% - 5% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 MIX DESIGN I.D.: 38 PLACEMENT DATE: 05/09/2002 WEATHER CONDITIONS: Cloudy TIME SAMPLED: 1:OOpm BATCH TIME: 12:26pm TEMPERATURE (I) - AIR 65 F CONCRETE: 90 F TRUCK NO: 1040 TICKET NO: 7116441 AM CONTENT ( %): 4.5 UNIT WEIGHT (pc NA OVERALL PLACEMENT LOCATION: Light pole on the median of State Street, turning into the west parking lot SAMPLE LOCATION: 30' south from the apex of median ASTM C -39 REPORT OF TESTS of State Street light pole Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MARKED SET NO. 1 1 1 2 1 3 1 4 MEASURED COMPRESSIVE SLUMP DATE AGE (inches) TESTED (days) 4.0 05/16/2002 7 4.0 4.0 Technician: Anthony Maldonado Report Distribution: (1) City of Coppell (1) City of Coppell (1) City of Coppell (1) Infrastructure Services, Inc. 06/06/2002 C28 06/06/2002 Hold Started: 12:30pm Finished: 2:OC (1) City of Coppell (1) Schrickel, Rollins & Assoc., Inc. MAXIMUM COMPRESSIVE LOAD STRENGTH FRACTURE (lbs. force) (psi) TYPE 94345 3340 Unbonded Cap 127775 4520 Unbonded Cap 126595 4480 Unbonded Cap Average 4500 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. O1DK Page 1 of 1 Project Manager