Amberpoint BP-LR020617CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0298 Service Date: June 7, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 17, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 5:29am Plant: 16 Supplier: Potter Truck No: 105 Mix I.D. No.: 7752 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 613985 Sample Information sample Time: 6:00am Technician: Joey Gordon Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Pump Sample Locations: See placement location Placement Location: See page 1 Date Cast: June 7, 2002 Sample location: Paving- 190' W of NE corner of building & 19' N of N wall Result Specification Test Method 5.75 4-6 ASTM C-143 4.2 3-6 ASTM C-231 76 ASTM C1064 73 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 06/14/2002 7 93,960 3,320 2 2 6.00 28.27 06/14/2002 7 90,730 3,210 Average 3,270 2 3 07/05/2002 28 2 4 07/05/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0298 Service Date: June 7, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630~1010 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 17, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 6:06am Plant: 16 Supplier: Potter Truck No: 115 Mix I.D. No.: 7752 Ticket No: 613993 Sample Information Sample Time: 6:45am Date Cast: June 7, 2002 Technician: Joey Gordon Weather Conditions: Partly cloudy Accumulative Yards: 10 Placement Method: Pump Sample Locations: See placement location Placement Location: See page 1 Sample location: Paving- 130' E of NW corner of building & 12' N of N wall Field Test Data Test Result Specification Test Method Slump, inches: 5.00 4-6 ASTM C-143 Air Content, %: 5.1 3-6 ASTM C-231 Concrete Temperature, o F: 78 ASTM Cl 064 Ambient Temperature, o F: 74 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 06/14/2002 7 96,300 3,410 3 2 6.00 28.27 06/14/2002 7 105,080 3,720 Average 3,570 3 3 07/05/2002 28 3 4 07/05/2002 28 Services - Obtain samples of fresh concrete at the placement locations, pe~orm required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of tl~ client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 o,~w~,~..~.~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0298 Service Date: June 7, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 17, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 7:29am Supplier: Potter Truck No: 112 Mix I.D. No.: 7752 Plant: 16 Field Test Data Test Result Slump, inches: 5.75 Air Content, %: Concrete Temperature, o F: 77 Ambient Temperature, o F: 73 Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 614007 Sample Information Sample Time: 8:15am Date Cast:June 7, 2002 Technician: Joey Gordon Weather Conditions: Partly cloudy Accumulative Yards: 10 Placement Method: Pump Sample Locations: See placement location Placement Location: See page 1 Sample location: Paving: 30' E of NW corner of building & 16' N of N wall Specification Test Method 4-6 ASTM C-143 3-6 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 I 6.00 28.27 06/14/2002 7 100,400 3,550 4 2 6.00 28.27 06/14/2002 7 103,480 3,660 Average 3,610 4 3 07/05/2002 28 4 4 07/05/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Joey Gordon Report Distribution: (1) Transwestem Commercial Services (1) O'Brien & Associates Inc (1) TechniStruotures Inc (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC Engin~~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable ' to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0298 Service Date: June 7, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 17, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 4:50am Supplier: Potter Truck No: 108 Mix I.D. No.: 7752 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 613979 Sample Information Sample Time: 5:20am Date Cast:June 7, 2002 Technician: Joey Gordon Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Pump Sample Locations: 140' W of NE corner, 16' N of N wall Placement Location: Paving- 100' W of NE corner of building to 130' E of NW corner of bldg. from N side of building to 25' N of N side of building Result Specification Test Method 5.50 4-6 ASTM C-143 4.2 3-6 ASTM C-231 77 ASTM C1064 73 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 06/14/2002 7 101,560 3,590 1 2 6.00 28.27 06/14/2002 7 99,180 3,510 Average 3,550 1 3 07/05/2002 28 1 4 07/05/2002 28 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein ara only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4 o,._Lw~o,