Creekview P2 L1R BA-CS020620T H E G 1 T Y O F COPPELL ~ r ~~, o ~ F x A g , B Q June 20, 2002 John W. Spiazs, P.E. Spiars Engineering, Inc. 700 E. Pazk Blvd., Suite 210 Plano, TX 75074 RE: Salon on the Creek Construction Plan Comments - ls` Review Dear Mr. Spiars: The City of Coppell has reviewed the referenced plans and has the following comments to offer: Generat Note - Provide a detail of the median island nose modification showing changes to the brick pavers and landscaping. Sheet Cl - Did you intend the parking striping paint to be 4" rather that 6" as stated? Sheet C2 - 1. Update the General Notes to match those on Sheet C1. 2. How will you address the conflict of the guardrail with the ADA ramp on the north side of the driveway on Denton Tap? 3. If it is your intention to not install a lime subgrade beneath your paving, a written request for waiver must be made to the City. That request is generally approved for private paving as long as the strength of the concrete is increased to 4000 psi or the thickness is increased by one inch. Any paving within public right-of--way still requires aflex-base subgrade. 4. There is a conflict between the proposed sidewalk location and the existing utility box on Bethel Road. How will this be addressed? Sheet C3 - 1. Include a detail for the grouted rip-rap outfall. 2. It appeazs that some of the proposed contours are mislabeled. 3. Verify the elevation at the property line of the driveway onto Bethel Road as it may be too low. Sheet C4 - 1. Indicate that the connection to the 8" sanitary sewer is with an outside drop. 253 PARKWAY * P. O.BOX 478 * COPPE LL TX 78D19 * TEL 972/462 0022 * FAX 972/306 3873 2 2. Relocate the fire hydrant on Denton Tap Road within the right-of--way or existing utility easement. Relocate the fire hydrant on Bethel Road within the right-of--way or provide an additional easement. Any additional easements need to be shown on the plat. 3. Indicate the location of the Fire Department Connection for the building. 4. Valves are required at the fire hydrant connections. Sheet C5 - On your Erosion Control Plan, please show the washout area for concrete and the containment area for that washout azea. Please make the necessary changes and submit these marked-up plans and two sets of revised plans to the City for the second review. If you have any questions, please contact this office at your convenience. Sincerely, ~x-~.a. ~v-,~.a'' Teresa Turner, E.I.T. Graduate Engineer Office Phone: (972) 304-3681 Fax: (972) 304-3570