ST0001-LR020618RoneEng nee s 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Ama: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 149973 · Project No.: 015729 Date of Service: 05/16/2002 Report Date: 06/18/2002 Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field te~ting, cast compressive strength sample~ and bring sample~ back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST MgTHOD: CONTRACTOR: In frastructure Services, -Inc. CONCRETE SUPPLIER: La~imore PLA~r: 7 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 42 PLACZMXNT DATE: 05/16/2002 WEATHER CON~mONS: Cloudy TIM~ SAMPLED: 12:30pm BATCH TIME: 11:49am TEMPERATURE (F} - AIR 70 F CONCRETE: 90 F T~UCK NO: 1040 TICKET nO: 7116679 AIR CONTENT (%): 4.25 uNrr WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: Paving - State Street (median center) turn into west parking lot of Wagon Wheel Baseball SAMPLE LOCATION: REPORT OF TESTS 15' south x 2' east of apex of median center Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP SET NO. Onches) MAXIMUM DATE AGE LOAD TESTED (days) Obs. force) COMPRESSiV~ STRENGTH FRACTURE (psi) TYPE 1 1 3.0 05/23/2002 7 109555 3870 Unbonded Cap 1 2 3.0 I 3 3.0 06/13/2002 28 124780 06/13/2002 28 126850 Average 4410 Unbondcd Cap 4490 Unbonded Cap 4450 1 4 Technician: Anthony Maldonado Report Distribution: (l} City of Coppoll (1) City of Coppell (1) city of Coppoil (1) Infrastructure Services, Inc. Hold Started: 12:00pm Finished: 3:00pm (1} City of Coppdl (1) Schrickcl, Rollins & Assoc., Inc. LIMITATIONS: The test results presented herein were p~-~parod based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, crc.) or any other feature of similar subject matter provided by pe~ons or conditions over which we have no control. Our letters and reports are for thc exclusive nsc of the clients to whom they are addressed and shall not be reproduced except in full without thc written approval of Rone Engineers, Inc. 01DK . ~-,~ Page 1 of I RoneEngineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-974S (214) 6309819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 151546 Project No.: 015729 Date of Service: 06/07/2002 Report Date: 06/18/2002 ~Txeelorie.w, Drive an~d Fre~ort Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength seanples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENK;I'H: SLUMP On): AIR (%): TEST METHOD: CONTm~CTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: TXI et~rr: 41 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN LD.: 9982 PLACEMENT DATE: 06/07/2002 WEATHER CONDITIONS: C1ca.r ~M~ SAMPI~O: 12:40pm BATCH Tram: NA TEM~'ERATURE 0~)- Am 86 r CONCRE~: 84 F TRUCX NO: 456 TICmgT NO: 3144414 Am CONTZNT (%): 3.2 uNrrwEit;~rr(pc0: NA OVERALL PLACEMENT LOCATION: Paving - south approach (red) to baseball fields SAMPLE LOCATION: 8' north x 2' west of southeast REPORT OF TESTS comer of approach Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) Obs. force) (psi) TYPE 1 1 4.5 06/14/2002 7 109940 3890 Unbonded Cap 1 2 4.5 07/05/2002 2/28 Unbonded Cap 1 3 4.5 07/05/2002 ~ Unbonded Cap 1 4 Hold Technician: Jason Barker Started: 11:30am Finished: 1:30pm txuue r,a~g~u~:/~~ Report Distribution: (1) City of Coppell O) city o~Co~pen ., ~ Clay Sta~k (1) Infrastmeture Services, he. ~,~, ~' ~, ~ Project Man~ger LIMITATIONS: The test results preseat~ herein were prepared based upon the specific' ~ samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by p~sons or conditions over which we have no control. Our letters and rq~orts are for the e~clusive use of the clients to whom they are addressed end shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 1 of 1 8908 Ambassndor Row Dallas, Texas 75247-4510 (21.4) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Atln: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 151516 Project No.: 015729 Date of Service: 06/07/2002 Report Date: 06/18/2002 Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to thc laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONT~ACrOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Latffmore PLANT: 7 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C- 1064 ASTM C-138 ASTM C-39 MIX DES1GN I.D.: 38 PLACEMENT VAT~: 06/07/2002 WEATHER CONDITIONS: Cloudy TIM~SAMPLED: 6:40am BATCHTIME: NA TEMPERATURE (F) - AIR 70 F CONCRETE: 80 F TRUCK NO: 1092 TICKET NO: 7117352 Am CO~n'ZNT (%): 4.4 trait WEIGHT (pet): NA OVERALL PLACEMENT LOCATION: Sidewalk in front of park at Creckview on Freeport Parkway SAMPLE LOCATION: REPORT OF TESTS 150' south x 2' east of ncrthwest corncr of sidewalk Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP SET NO. (inches) MAXIMUM DATE AGE LOAD TESTED (days) 0b~. force) COMPRESSIVE STRENGTH FRAL'i'URE (p~) ~E 1 1 5.25 06/14/2002 7 83830 2960 Unbonded Cap 1 2 5.25 I 3 5.25 07/05/2002 28 07/05/2002 28 Unbonded Cap Unbonded Cap I 4 Hold Water added at site: 10 gallons Notified contractor of slump. Technician: Eric White Report Distribution: (I) City of Coppell (I) City of Coppoll (1) Infrastructure Services, Inc. (1) Scinickel, Rollins & Assoc., Inc. Started: 5:30am Finished: 9:00atn Ro~_ n~, Inc. LIM/TATIONS: The test r~sults presented herein were prepared based upon the specific sampl~ provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of sim/lar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Pone Engineers, Inc. 01DK Page 1 of 1