ST0001-LR020607 (2) .gineers 8908 Ambassador Row Dallas, Texas 7S247-4510 (:114) 6309745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Arm: Ms. Susan Taylor - Engineering Dept PO Box 478 Copper TX 75019 Report No.: 150780 Project No.: 015729 Date of Service: 05/30/2002 Report Date: 06/07/2002 Coppell, TX Obtain samples of fresh comae~e at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: COb'fRAe'fOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 6 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C- 1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 42 I'LACZSmNT OATE: 05/30/2002 WZATIlgR CONDITIONS: Clear T1MESAMPLED: 8:40am BATCHTIME: 7:42am TEMPERATURE (F) - AIR 75 F CONCRETE: 83 F ~UC~CNO: 980 TICg~TNO: 617590 Am COSTESr (%): 4.5 VNIT WEIGHT (Pc0: NA OVERALL PLACEMENT LOCATION: Paving - curb and gutter, north lane, we~t end of Crenkview and north and south lane at cast end of Crenkview and State SAMPLE LOCATION: 10' east x 2' north of northwest REPORT OF TESTS comer of placement Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP DATE SET NO. 0riches) TESTED 1 1 3.0 06/03/2002 1 2 3.0 06/06/2002 1 3 3.0 06/27/2002 1 4 3.0 06/27/2002 ! 5 Hold MAXIMUM COMPRESSIVE AGE LOAD STRENGTH FRACTURE (days) 0bs. force) (psi) TYPE 4 115055 4070 Unbondcd Cap q 117115 ~l~40 Unbonded Cap ~d~ap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for tesring. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subjec! roarer provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 1 of 2 Report No.: 150780 RoneEngineers Project No.: 015729 Client: City of Coppell ~ll Water added at site: 5 gallons Technician: Anthony Maldonado Report Distribution: (1) City of CoPP~ll (1) City of Copp~ll (1) City of Copp~ll (1) Infrastructure S,:rvic~, Inc. Started: 7:00am Finished: 11:00am (1) City of Coppoll (I) Schrickel, Rollins & Assoc., Inc. Rone E~, Cla9'8~ Project Manager LIMITATIONS: The teat results proscnted herein wvr~ Inqmred based upon the sp~ific samples provided for testing. We assume no responsibility for variation in quality (composition, appearanoe, performance, etc.) or any oth~ feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclnsiv¢ use of thc clients to whom they are addressed and shall not be rv'produced except in full without the written approval of Rone Enginceca, Inc. 01DK Page 2 of 2 Client: Infrnstructure Services, Inc. At-m: Mr. Phillip Bennett PO Box 496448 Garland TX 75049-6448 Project: Creekview Drive and Freeport Parkway Coppell, TX Services: Concrete Impection 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (~14) 630-9819 (fax) REPORT OF CONCRETE INSPECTION Report No.: 151389 Project No.: 026186 Date of Service: 05/02/2002 Report Date: 06/07/2002 Report of Inspection On this date, a Rone Engineers, Inc. representative was on site to perform a Concrete Inspection. See Report ~149030 for results. Technician Time: Page 1 of 1 2:00 aum to 7:00 am 3:00 pm to 6:00 pm Technician: Anttlony Maldonado Report Distribution: (1) Infraamtctum Services, Inc. (1) City of Coppell (1) City of Coppell (1) City of Coppell (1) Infrastructure Services, Inc. (1) Schrickel, Rollins & Assoc., Inc. C , Stark Project Manager LIMITATIONS: The test results presented herein were prepered based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no con~rol. Our letters and reports ere for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written appwval of Rone Eng/ncers, Inc. 99CM PaRe 1 of 1