ST0001-LR020619. � i A LEIGH COMPANY 7q 8908 Ambassador Row Dallas, Texas 75247 -4510 (214) 630 -9745 (214) 630 -9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Report No.: 150205 Attn: Ms. Susan Taylor - Engineering Dept Project No.: 015729 PO Box 478 Date of Service: 05/21/2002 Coppell TX 75019 Report Date: 06/19/2002 Project: Creekview Drive and SLUMP (in): Freeport Parkway AIR ( %): Coppell, TX TEST METHOD: Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. ASTM C -31 PROJECT DATA CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi @ 28 Days SLUMP (in): 3" - 5ti AIR ( %): 3% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 MIX DESIGN I.D.: 115702 PLACEMENT DATE: 05/21/2002 WEATHER CONDITIONS: Sunny _ TIME SAMPLED: 2:00pm BATCH TIME: 12:27pm TEMPERATURE (F) -AIR 85 F CONCRETE: 85 F TRUCK NO: 1045 TICKET NO: 16249 AIR CONTENT (% 3.4 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Creekview retaining wall footing ASTM C -138 SAMPLE LOCATION: South side of street at ASTM C -39 REPORT OF TESTS Station 0 +50, 5 off curb Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (Ibs. force) (psi) TYPE 1 1 3.0 05/28/2002 7 95160 3370 Unbonded Cap 1 2 3.0 06/18/2002 28 130805 4630 Unbonded Cap 1 3 3.0 06/18/2002 28 126285 4470 Unbonded Cap Average 4550 1 4 Hold Water added at site: 10 gallons Technician: Simon Gibbons Started: 12:3Opm Finished: 4:00pm revue Tp} , Report Distribution: /� (I) City of Coppell (1) City of Coppell (1) City of Coppell (1) Schrickel, Rollins & Assoc., Inc. Clay It (1) City of Coppell Project Manager (1) Infrastructure Services, Inc. i LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. O1DK Page 1 of 1