Amberpoint BP-LR020619CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0303 Service Date: June 11,2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 ENGIN~f!IUNG 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 i1 Report Date:~J~'~9, 2002 ~ Project: ,~ffberpoint Building No.~ ~mberpoint Bus. Pk. @~'oppell (~ppell, T exas_~,~" Project N u r~l~'~'~I~''Z~29 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 5:31am Supplier: Potter Truck No: 105 Mix I.D. No.: 7752 Plant: 16 Ticket No: 614051 Sample Information Sample Time: 6:15am Date Cast: June 11,2002 Technician: Joey Gordon Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Paving- NW corner of building to SW corner of building & SW corner of building to SW loading dock to 20' W of W wall Field Test Data Test Sample location: 30' S of NW corner of building & 12' W of W wall Result Specification Test Method 5.75 4-6 ASTM C-143 4.2 3-6 ASTM C-231 76 ASTM C1064 74 ASTM C-1064 Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 06/18/2002 7 101,050 3,570 1 2 6.00 28.27 06/18/2002 7 101,490 3,590 Average 3,580 1 3 07/09/2002 28 1 4 07109/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. lhe tests were performed in general accordance with applicable ASTM, AASHIO, or DOT test methods, lhis report is exclusively for the use of the cliont indicated above and shall not ~ reproduced except in lull mthout the wd~en approval of Termcon. Test results tmnsm~e0 herein am only applicable to the actual samples tested at the location(s) re[stunted and are not necessarily indicative of tho pro~die* of other apparently similar or identical materials. Page 1 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0303 Service Date: June 11,2002 8901 Carpenter Frwy,, Suite#100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 19, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. ~ Coppell Coppetl, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 6:27am Plant: 16 Supplier: Potter Truck No: 105 Mix I.D. No.: 7752 Field Test Data Test Ticket No: 059 Sample Information Sample Time: 7:05am Technician: Joey Gordon Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: See page 1 Date Cast: June 11,2002 Sample location: 70' S of NW corner of building & 6' W of W wall Result Specification Test Method Slump, inches: 6.00 4-6 ASTM C-143 Air Content, %: 4.6 3-6 ASTM C-231 Concrete Temperature,° F: 76 ASTM C1064 Ambient Temperature, o F: 73 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 06/18/2002 7 102,780 3,630 2 2 6.00 28.27 06/18/2002 7 108,480 3,840 Average 3,740 2 3 07/09/2002 28 2 4 07/09/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were pedormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the prepedies of other apparently similar or identical materials. Page 2 of 4 o~ ~w~, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0303 Service Date: June 11,2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 19, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. ~ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 8:11am Plant: 16 Supplier: Potter Truck No: 112 Mix I.D. No.: 7752 Field Test Data Test Result Slump, inches: 5.75 Air Content, %: 4.1 Concrete Temperature,o F: 85 Ambient Temperature, o F: 82 Plastic Unit Weight, pcf: Laboratory Test' Data Ticket No: 614072 Sample Information Sample Time: 9:05am Technician: Joey Gordon Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: See page I Date Cast: June 11, 2002 Sample location: 40' N of SW corner of building & 12'W of Wwall Specification Test Method 4-6 ASTM C-143 3-6 ASTM C-231 ASTM C1064 ASTM C-1064 3 3 07/09/2002 3 4 07/09/2002 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 06/18/2002 7 101,670 3,600 3 2 6.00 28.27 06/18/2002 7 102,900 3,640 Average 3,620 28 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 o~ ~o, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0303 Service Date: June 11,2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 19, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 9:21am Plant: 16 Supplier: Potter Truck No: 112 Mix I.D. No.: 7752 Field Test Data Test Ticket No: 614080 Sample Information Sample Time: 10:10am Technician: Joey Gordon Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: SW loading dock, 10' S of S wall Placement Location: See page 1 Date Cast: June 11, 2002 Result Specification Test Method Slump, inches: 6.00 4-6 ASTM C-143 Air Content, %: 4.5 3-6 ASTM C-231 Concrete Temperature, o F: 83 ASTM C1064 Ambient Temperature, o F: 79 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 1 6.00 28.27 06/18/2002 7 108,520 3,840 4 2 6.00 28.27 06/18/2002 7 102,470 3,620 Average 3,730 4 3 07/09/2002 28 4 4 07/09/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Joey Gordon Report Distribution: (1) Transwestern Commercial Services (1) O'Bden & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC Engine/g~ Eugene Harbour Principal The tests were ped'ormed in general accordance with applicable ASTM, AASHTO. or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 4 of 4