Amberpoint BP-LR020618CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0286 Service Date: May 20, 2002 ENG INf~ P. ING 8901 Carpenter Rwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 18, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: 3:12pm Supplier: Potter Truck No: 111 Mix I.D. No.: 9337 Plant: 16 Field Test Data Test Ticket No: 613899 Sample Information sample Time: 3:55pm Date Cast: May 20, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 20 Placement Method: Direct Discharge Sample Locations: 0.7, 10.6 Placement Location: Grade beams 0.7-0 & 10.5-11 Result Specification Test Method Slump, inches: 5.00 ASTM C-143 Air Content, %: 2.4 ASTM C-231 Concrete Temperature, o F: 77 ASTM Cl 064 Ambient Temperature, o F: 80 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 05/27/2002 7 129,320 4,570 1 2 6.00 28.27 05/27/2002 7 122,470 4,330 Average 4,450 1 3 6.00 28.27 06/17/2002 28 164,780 5,830 1 4 6.00 28.27 06/17/2002 28 168,770 5,970 Average 5,900 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppell - Constr Insp HBC Eng~ (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson Ltd Reviewed by: (1) Halff Associates Eugene R~.rbour (1) State Farm Insurance Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 0~ ~w~o, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0284 Service Date: May 20, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 18, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 7:28am Plant: 16 Supplier: Potter Truck No: 102 Mix I.D. No.: 7752 Field Test Data Test Ticket No: 613837 Sample Information Sample Time: 8:10am Date Cast: May 20, 2002 Technician: Marvin Arandia Weather Conditions: Clear Placement Method: Sample Locations: See placement location Placement Location: Pavement N of building (See attached sketch) Result Specification Test Method Slump, inches: 4.00 ASTM C-143 Air Content, %: 3.2 ASTM C-231 Concrete Temperature,° F: 74 ASTM C1064 Ambient Temperature, o F: 68 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 05/27/2002 7 148,770 5,260 1 2 6.00 28.27 05/27/2002 7 146,350 5,180 Average 5,220 1 3 6.00 28.27 06/17/2002 28 168,270 5,950 1 4 6.00 28.27 06/17/2002 28 169,350 5,990 Average 5,970 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6 o, LLw,"a,.~.~.~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0284 Service Date: May 20, 2002 ENGINEERING 8901 Carpenter Frwy,, Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 18, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppelt, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 8:15am Plant: 16 Supplier: Potter Truck No: 102 Mix I.D. No.: 7752 Field Test Data Test Ticket No: 613845 Sample Information Sample Time: 8:40am Date Cast: May 20, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 100 Placement Method: Pump Sample Locations: See placement location Placement Location: See page 1 Result Specification Test Method Slump, inches: 5.50 ASTM C-143 Air Content, %: 4.4 ASTM C-231 Concrete Temperature, o F: 74 ASTM Cl 064 Ambient Temperature, o F: 67 ASTM C-1064 Plastic Unit Weight, pcf: Laboratorl/ Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 05/27/2002 7 113,140 4,000 2 2 6.00 28.27 05/27/2002 7 114,820 4,060 Average 4,030 2 3 6.00 28.27 06/17/2002 28 144,150 5,100 2 4 6.00 28.27 06/17/2002 28 139,300 4,930 Average 5,020 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terrecon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0284 Service Date: May 20, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 18, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 9:25am Plant: 16 Supplier: Potter Truck No: 115 Mix I.D. No.: 7752 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.50 4.8 75 73 Ticket No: 613856 Sample Information sample Time: 10:00am Date Cast: May 20, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 200 Placement Method: Pump Sample Locations: See placement location Placement Location: See page 1 Specification Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 3 1 6.00 28.27 05/27/2002 3 2 6.00 28.27 05/27/2002 3 3 6.00 28.27 06/17/2002 3 4 6.00 28.27 06/17/2002 Test Method ASTM C-143 ASTM C-231 ASTM Cl 064 ASTM C-1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 124,530 4,400 7 125,350 4,430 Average 4,420 28 142,770 5,050 28 144,100 5,100 Average 5,080 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6 01'LLW~°~ E~e Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0284 Service Date: May 20, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 18, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 10:04am Plant: 16 Supplier: Potter Truck No: 106 Mix I.D. No.: 7752 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.50 5.1 76 78 Set Specimen Diameter Area No. ID (inches) (sq. inches) 4 1 6.00 28.27 4 2 6.00 28.27 4 3 6.00 28.27 4 4 6.00 28.27 Ticket No: 613864 Sample Information Sample Time: 11:05am Date Cast: May 20, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 300 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C 1064 ASTM C- 1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 05/27/2002 7 114,330 4,040 05/27/2002 7 118,620 4,190 Average 4,120 06/17/2002 28 141,580 5,010 06/17/2002 28 141,270 5,000 Average 5,010 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials~ Page 4 of 6 0, ~w~e, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0284 Service Date: May 20, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 18, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 11:49am Plant: 16 Supplier: Potter Truck No: 115 Mix I.D. No.: 7752 Field Test Data Test Result Slump, inches: 4.00 Air Content, %: 4.9 Concrete Temperature,o F: 75 Ambient Temperature, o F: 79 Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 613879 Sample Information Sample Time: 12:35pm Date Cast: May 20, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 410 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 5 1 6.00 28.27 05/27/2002 7 137,530 4,860 5 2 6.00 28.27 05/27/2002 7 135,640 4,800 Average 4,830 5 3 6.00 28.27 06/17/2002 28 159,020 5,620 5 4 6.00 28.27 06/17/2002 28 173,800 6,150 Average 5,890 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of ether apparently similar or identical materials. Page 5 of 6 o~ LLW/~°I CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0284 Service Date: May 20, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd. Suite 600W Dallas TX 75244 Report Date: June 18, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, Texas Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: Plant: 16 Supplier: Potter Truck No: 102 Ticket No: Mix I.D. No.: 7752 Field Test Data Test Sample Information sample Time: 2:00pm Date Cast: May 20, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 500 Placement Method: Direct Discharge Sample Locations: See page 1 Placement Location: See page 1 Result Specification Test Method Slump, inches: 5.00 ASTM C-143 Air Content, %: 5.2 ASTM C-231 Concrete Temperature, o F: 76 ASTM C1064 Ambient Temperature, o F: 80 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 6 I 6.00 28.27 05/27/2002 7 115,660 4,090 6 2 6.00 28.27 05/27/2002 7 117,540 4,160 Average 4,130 6 3 6.00 28.27 06/17/2002 28 142,320 5,030 6 4 6.00 28.27 06/17/2002 28 142,270 5,030 Average 5,030 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures Inc (1) City of Coppelt - Constr Insp (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson Ltd (1) Halff Associates (1) State Farm Insurance Reviewed by: HBC Engi~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 6 of 6 o~.~w,~ PROJECT: PROJECT NO.: CALCD. OY: CHKD BY: DATE: DATE: ENGINEERING, INC. ~ 2 ..3 -r