ST0001-LR020620L , . A LEIGH COMPANY 8908 Ambassador Row Dallas, Texas 752474510 (214) 630 -9745 (214) 630 -9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Project: Creekview Drive and Freeport Parkway Coppell, TX Report No.: 150290 Project No.: 015729 Date of Service: 05/22/2002 Report Date: 06/20/2002 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIE Lattimore PLANT: 6 SPECIFICATION REQUIREMENTS STRENGTH: 3000 psi @ 28 Days SLUMP (in): 3" - 5" AIR ( %): TEST METHOD: 3%-5% MIX DESIGN I.D.: 38 PLACEMENT DATE: 05/22/2002 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 1:30pm BATCH TIME: 12:39pm TEMPERATURE M - AIR 80 F CONCRETE: 90 F TRUCK NO: 941 TICKET NO: 6175509 AIR CONTENT ( % 4.25 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Rock wall (Creekview) south lane going eastbound, Station 3 +50 to approximate Station 6 +50 SAMPLE LOCATION: Station 4 +50 ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKE SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (Ibs, force) (psi) TYPE 1 1 3.0 05/29/2002 7 94450 3340 Unbonded Cap 1 2 3.0 06/19/2002 28 109445 3870 Unbonded Cap 1 3 3.0 06/19/2002 28 120695 Unbonded Cap Average 4070 1 4 Hold O o W Water added at site: 5 gallons e Technician: Anthony Maldonado Started: 12: p Finished: 2:30pm eG Inc. Report Distribution: • (1) City of Coppell ra;z� (1) City of Coppell r o Clay Stark (1) Infrastructure Services, Inc. 1 .'Project Manager (1) Schrickel, Rollins & Assoc., Inc. LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 1 of 1