Amberpoint BP-LR020621CONCRETE COMPRESSIVE STRENGTH TEST awyi.r flk �
Report Number: 94021029.0288 Lzr- xN axsM
Service Date: May 23, 2002 8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630 -1010
Client: Transwestern Commercial Services Report Date: June 21, 2002
Attn: Jim Gaspard Project: Amberpoint Building No. 1
5001 Spring Valley Rd. Suite 600W AM oppell
Dallas TX 75244 Coppell, Texas
Project Number: 9402102
Material Information Sample Information
Specified Strength: 3500 psi @ 28 Days Sample Time: 2:!5pm Date Cast: May 23, 2002
Technician: Marvin Arandia
Batch Time: Plant: 22 Weather Conditions: Partly cloudy
Supplier: Hanson Accumulative Yards: 10
Truck No: 9 Ticket No: 100694 Placement Method: Direct Discharge
Mix I.D. No.: 9337 Sample Locations: 15' N of NE corner of building
Placement Location: Pier cap- NE & NW of tilt panels- 25, 15 &
TN of corner building
Field Test Data
Test
Result
Specification
Test Method
Slump, inches:
5.00
ASTM C -143
Air Content, %:
2.4
ASTM C -231
Concrete Temperature,° F.
80
ASTM C1064
Ambient Temperature, 0 F:
77
ASTM C -1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum
Compressive
Set Specimen Diameter
Area
Date
Test Load
Stren th
No. ID (inches)
( sq. inches
Tested
(days) (lbs)
(psi
1 1 6.00
28.27
05/30/2002
7 115,950
4,100
1 2 6.00
28.27
05/30/2002
7 114,280
4,040
C28 verage ,070
1 3 6.00 28.27 06/20/2002 141,590 5,010
1 4 6.00 28.27 06/20/2002 139,020
verage 4,970
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Marvin Arandia
ow e oa
Report Distribution: HBC En Ing
(1) Transwestem Commercial Services (1) City of Coppell - Bldg Insp
(1) O'Brien & Associates Inc (1) Hill & Wilkinson Ltd Reviewed by
(1) TechniStructures Inc (1) Halff Associates Eugene Harbour
(1) City of Coppell - Constr Insp (1) State Farm Insurance Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 01aLWA 11r Key