Northpoint Dr-LR020620 CONCRETE COMPRESSIVE STRENGTH TEST ~.Report Number: 94021061.0043 Service Date: May 23, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 21, 2002 Project.;_NorthJ~oint Driv~ & -- Coppell, Texas Project Number: 94021061 8~)1 Carpenter Rwy., SuEe#100 Da#sa, Texas75247 (214)630-10t0 Material Information Specified Strength: 3600 psi ~ 28 Days Batch Timei Plant: 1 Supplier: GTI Truck No:. Ticket No: Mix I.D. No.: 2329 Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 3.8 Concrete Temperature,o F: 80 Ambient Temperature, o F: 73 Plastic Unit Weight, pcf: 147.0 Laboratory Test Data set Specimen Diameter Area No. ID (inches) (~) I 1 6.00 28.27 I 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 1 5 6.00 28.27 Sample Information Sample Time: 11:45am Date Cast: May 23, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 600 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Pavement- SW of Amberpoint Sample location: N Point Rd. approach to water tower entrance Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age ~t Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 05/28/2002 5 90,660 3,210 05~28~2002 5 97,030 3,430 Average 3,320 05/30/2002 7 112,580 3,g80 06/20/2002 28 120,610 j~,270 06/20/2002 28 122,260 ~1~r~320 Average 4,300 Services- Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were perfon~ed in general accordance with applicable ASTM, AASHTO, or DOT test metlxx~s. This report is exclusively for the use of the client indicated above and shall not be reproduced excepl in full without the written approval of Ten'aeon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are no{ necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0043 Service Date: . May 23, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 21,2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Caq~enter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3600 Psi ~ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: I Ticket No: Field Test Data Test Result Slump, inches: 5.50 Air Content, %: 3.6 Concrete Temperature,o F: 80 Ambient Temperature, o F: 77 Plastic Unit Weight, pcf: 146.6 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (scl; inches) 2 1 6.00 28.27 Sample Information Sample Time: 3:30pm Date Cast: May 23, 2002 Technician: Marvin Arandia Weather Conditions; Cloudy Accumulative Yards: 600 Placement Method: Direct Discharge Sample Locations: N Point Road 1+75 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (bs~ 05~27/2002 4 97,960 3,460 2 2 6.00 28.27 05~30/2002 7 1i0,830 3,920 2 3 6.00 28.27 05/30/2002 7 107,750 3,810 Average 3,870 2 4 6.00 28.27 06/20/2002 28 120,230 jf~ ,250 2 5 6.00 28.27 06/20/2002 28 120,880 ~,~,270 Average 4,260 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestem Commercial Services (1) Glenn Thurman Inc (1) Halff Associates (1) c~ of coppeil - Engineering (1) City of Coppeil - Bldg Insp (1) State Farm Insurance (1) Moss Construction Reviewed by: Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test msthods. This report is exclusively for the use of the client indicated above and shell ne~ be reproduced except in full witho~ the written approval of Terra¢o~. Test reS~lta transmitted herein ara only appllc, ab~e to the actual samples tested at the location(s) referenced and are nnt necessarily indicative of the properties of other apparently similar or identical mstmleis. Page 2 of 2 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0042 Service Date: May 23, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 21, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Rwy., Suite #100 Dalles, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2328 Plant: 1 Ticket No: Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 4.0 Concrete Temperature? F: 67 Ambient Temperature, o F: 80 Plastic Unit Weight, pcf: 148.0 Laboratory Test Data Set Specimen No. ID I 1 I 2 Sample Information Sample Time: 8:10am Date Cast: May 23, 2002 Technician: Marvin Arandia Weather Cotiditions: Cloudy Accumulative Yards: 150 Placement Method: Direct Discharge Sample Locations: N Point Rd, Sta. 24+60 Placement Location: Pavement- S of Sandy Lake Road I 3 1 4 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum ComPressive Diameter Area Date Test Load Strength (inches) (scI. inches) Tested (days) (lbs) (ps~) 6.00 28.27 05/30/2002 7 97,990 3,470 6.00 28.27 05/30/2002 7 94,750 3,350 Average 3,410 6.00 28.27 06/20/2002 28 115,180 4,070 6.00 28.27 06/20/2002 28 110,180 3,900 Average 3,990 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The testa w~re p~formed in general accordance with applicable ASTM, AASHTO. or DOT test methods. This report is exclusively for the us~ of the blie~ indicated above and shall not be reproduced except in full ,without the written approval of Terreccn. Test results transmitted herein are only app~icabis to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3 ~.u.w~.,~,..,~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0042 Service Date: May 23, 2002 Client: Transwestem Commemial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 21, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 89Ol Carpenter Fray., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: Plant: 1 Supplier:. GTI Truck No: Ticket No: Mix I.D. No.: 2328 Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 4.6 Concrete Temperature, o F: 80 Ambient Temperature, o F: 71 Plastic Unit Weight, pcf: 148.8 Laboratory Test Data Set Specimen Diameter No. ID (inches) 2 1 6.00 2 2 6.00 Sample Information Sample Time: 9:10am Date Cast: May 23, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 300 Placement Method: Direct Discharge Sample Locations: N Point Road, Sta. 26+50 Placement Location: See page 1 2 3 6.00 2 4 6.00 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C~1064 Age at Maximum Compressive Area Date Test Load Strength (scI. inches) Tested (days) (lbs) (ps0 28.27 05/30/2002 7 112,730 3,990 28.27 05/30/2002 7 109,330 3,870 Average 3,930 28.27 06/2012002 28 128,900 4,560 28.27 06/20/2002 28 130,100 4,600 Average 4,580 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive. strength samples. The tests were performed in general aocordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicsted above and shell not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not nscesaarfly indicative of the properties of other apparently similar or identical materials. Page 2 of 3 o~',,,~-r*,~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0042 Service Date: May 23, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 21,2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Fn~y., Suite #100 Dallas, T= 75247 (214) 630-1010 Material Information Specified Strength: 3000 psi {~ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2328 Plant: 1 Ticket No: Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 4.6 Concrete Temperature,o F: 80 Ambient Temperature, o F: 72 Plastic Unit Weight, pcf: 148.2 Laboratory Test Data Set Specimen Diameter Area No~ ID (inches) (sq. inches) 3 1 6.00 28.27 3 2 6.00 28.27 3 3 6.00 28.27 3 4 6.00 28.27 Sample Information Sample Time: 10:10am Date Cast: May 23, 2002 Technician: Marvin Arandia Weather Conditions: Cloudy Accumulative Yards: 450 Placement Method: Direct Discharge Sample Locations: N Point Road, Sta. 28+20 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 05/30/2002 7 92,920 3,290 05~30~2002 7 98,480 3,480 Average 3,390 06/20/2002 28 124,270 4,390 06/20/2002 28 126,690 4,480 Average 4,440 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestern Commercial Services (1) Glenn Thurman Inc (1) Halff Asacciates (1) City of Coppait - Engineering (1) City of Coppall- Bldg Insp (1) State Farm Insurance (1) Moss Construction Reviewed by: HBC E~~ng Eugene Had3our Principal The tests were parforrned in general accordance with applicable ASTM, AASHTO, or DOT test methods. Thla report Is exclualvely for the use of the client indicated above and shall nc~ be reproduced except in full without the written aPproval of Terracon. Test results trencmltted herein are only applicable to the actual samples tested at the locetion(s) referenced and are not necessarily indicative of the properties of ofher apparently similar or Idantk:al matedala. Page 3 of 3 .-~,~,. ~ONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0040 ~ervice Date: May 21,2002 Client: Transwestern Commemial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: 1 Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data ResuE 5.25 2.8 78 75 Set Specimen Diameter Area No. ID (inches) (sq. inches) I I 6.00 28.27 I 2 6.00 28.27 1 3 6.00 28.27 1 4 6.0O 28.27 Sample Information Sample Time: 8:50am Date Cast: May 21, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 150 Placement Method: Direct Discharge Sample Locations: Sta. 0+50 Placement Location: Pavement S of Amberpoint Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (ps~ 05/28/2002 7 126,000 4,460 05/28/2002 7 122,400 4,330 Average 4,400 06/18/2002 28 149,350 5,280 06/18/2002 28 148,000 5,230 Average 5,260 Services - Obtain Samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The teats were pedormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use of the client indicated above and shell not be reproduced except in full without the written approval of Terracon. Test results transmitted horain are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6 ~ONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0040 'Service Date: May 21, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 .~'~ 8901 Caq3enter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: 1 Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Sample Information Sample Time: 10:50am Date Cast: May 21, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 300 Placement Method: Direct Discharge Sample Locations: Sta. 3+00 Placement Location: See page 1 Result Specification Test Method ASTM C-143 4.0 ASTM C-231 79 ASTM C1064 75 ASTM C-1064 148.6 ASTM C-138 Age at Test (days) Maximum Compressive Set Specimen Diameter Area Date Load Strength No. ID (inches) (sq. inches) Tested (lbs) (psi) 2 I 6.00 28.27 05/28/2002 128,120 4,530 2 2 6.00 28.27 05/28/2002 7 128,620 4,550 Average 4,540 2 3 8.00 28127 06/18/2002 28 155,720 ~f5',510 2 4 6.00 28.27 06/18/2002 28 147,850 230 Average 5,370 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM. AASHTO, or DOT test methods. This report is exclusively for the use indicated above and shall not be reproduced except in full without the written approval of Termcon. Test results transmitted herein ere only applicable to the actual samples tested at the location(s} referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6 ~,-~.~.w~,,..,~, CONCRETE COMPRESSIVE STRENGTH TEST ,Report Number: 94021061.0040 Service Date: May 21, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3600 psi O 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: 1 Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen No. ID 2 1 2 2 Sample Information Sample Time: 10:50am Date Cast: May 21,2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 300 Placement Method: Direct Discharge Sample Locations: Sta. 3+00 Placement Location: See page I 2 3 2 4 Result Specification Test Method ASTM C-143 4.0 ASTM C-231 79 ASTM C1064 75 ASTM C-1064 148.6 ASTM C-138 Age at Maximum Compressive Diameter Area Date Test Load Strength (inches) (sq. i.~_nches) Tested (days) (lbs) (psi) 6.00 28.27 05/28/2002 7 128,120 4,530 6.00 28.27 05/28/2002 7 128,620 4,550 Average 4,540 6.00 28127 06/18/2002 28 155,720 5,510 6.00 28.27 06/18/2002 28 147,850 5,230 Average 5,370 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use oTl~ ctlent indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein ere only apfllicabfe to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6 ~.~.-~.,w CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0040 ~ervice Date: May 21, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 ' 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 830-1010 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: 1 Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 3.00 4.7 85 77 149.2' Set Specimen Diameter Area No. ID '(inches) (sq._c.inches) 3 I 6.00 28.27 3 2 6.00 28.27 3 3 6.00 28.27 3 4 6.00 28.27 Sample Information Sample Time: 1:05pm Date Cast: May 21,2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 450 Placement Method: Direct Discharge Sample Locations: Sta. 4+50 Placement Location: See page I Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age at MaXimum Compressive Date Test Load Strength Tested (days) {lbsI (psi) 05/28/2002 7 109,330 3,870 05/28/2002 7 109,500 3,870 Average 3,870 06/18/2002 28 129,420 4,580 06/18/2002 28 133,700 4,730 Average 4,660 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are on~ ap~icabie to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other al3f3arenfly similar or identical materials. Page 3 of 6 ~ ~ONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0040 "Service Date: May 21, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas · Project Number: 94021061 8901 Caq~enter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3600 psi ¢~ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: I Ticket No: Field Test Data Test Sample Information Sample Time: 2:30pm Date Cast: May 21, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 600 Placement Method: Direct Discharge Sample Locations: Sta. 7+00 Placement Location: See page 1 Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Result Specification Test Method 3.00 ASTM C-143 3.9 ASTM C-231 80 ASTM C1064 85 ASTM C-1064 148.6 ASTM C-138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 I 6.00 28.27 05/28/2002 7 118,410 4,190 4 2 6.00 28.27 05/28/2002 7 115,350 4,080 Average 4,140 4 3 6.00 28.27 06/18/2002 28 131,910 ~ 4,660 4 4 6.00 28.27 06/18/2002 28 137,100 %~,,850 Average 4,760 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were perlormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of thereat indicated above and shall not he reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to ~he actual samples tested at b~e location(s) referenced and are not necassarily indicative of the properties of other apparenlJy similar or identical materials. Page 4 of 6 ~ONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0040 'Service Date: May 21, 2002 Client: Transwestern Commemial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: 1 Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 3.00 4.5 85 85 148.2 Set Specimen Diameter Area No. ID (inches) (sc{. inches) 5 1 6.00 28.27 5 2 6.00 28.27 5 3 6.00 28.27 5 4 6.00 28.27 Sample Information Sample Time: 3:45pm Date Cast: May 21,2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 75 Placement Method: Direct Discharge Sample Locations: Sta. 8+65 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 05/28/2002 7 125,780 4,450 05/28/2002 7 111,890 3,960 Average ~.-- 4,210 06/18/2002 28 140,480 r- 4,970 06/18/2002 28 142,980 Average 5,020 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terrecon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apperenity similar or identical materials. Page 5 of 6 ~;ONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0040 'Service Date: May 21,2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: Supplier: GTI Truck No: Mix I.D. No.: 2329 Plant: 1 Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen No. ID 6 1 6 2 Sample Information Sample Time: 4:25pm Date Cast: May 21, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 900 Placement Method: Direct Discharge Sample Locations: Sta. 10+65 Placement Location: See page 1 Result Specification Test Method 5.00 ASTM C-143 4.4 ASTM C-231 80 ASTM C1064 83 ASTM C-1064 148.6 ASTM C-138 Age at Maximum Compressive Diameter Area Date Test Load Strength (inches) (sq. inches) Tested (days) (lbs) (psO. 6.00 28.27 05/28/2002 7 93,190 3,300 6.00 28.27 05/28/2002 7 95,200 3,370 Services - Average 3,340 3 6.00 28.27 06/18/2002 28 115,530 4,090 4 6.00 28.27 06/18/2002 28 114,860 4,060 Average 4,080 Obtain samples of fresh concrete at the placement locations, pedorm required field tests and cast compressive strength samples. Technician: Marvin Arandia Report Distribution: (1) Transwestem Commemlel Services (1) Glenn Thurman lnc (1) Halff Associates (1) City of Coppell - Engineering (1) City of Coppell - Bldg Insp (1) State Farm Insurance (1) Moss Construction HBC Engineering Reviewed by: ~' Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods, This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terra(on. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6 ~ CONCRETE COMPRESSIVE STRENGTH TEST · Report Number: 94021061.0041 serVice Date: May 22, 2002 Client: Transwestem commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Fn~., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: Plant: On-Site Supplier: GTI Truck No: Ticket No: Mix I.D. No.: 2328 Field Test Data Test Result Slump, inches: 2.75 Air Content, %: 4.6 Concrete Temperature, o F: 75 Ambient Temperature, o F: 65 Plastic Unit Weight, pcf: 145.4 Laboratory Test Data Set Specimen No. iD 1 1~ 1 2 Sample Information Sample Time: 7:50am Date Cast: May 22, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 150 Placement Method: Direct Discharge Sample Locations: 10+50 Stationary Placement Location: Pavement SE of Amberpoint 1 3 I 4 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age at Maximum Compressive Diameter Area Date Test LOad Strength (inches) (sq. inches) Tested (days) (lbs) (ps~) 6.00 28.27 '05~29~2002 7 105,110 3,720 6.00 28.27 05/29/2002 7 101,460 3,590 Average 3,660 6.00 28.27 06/19/2002 28 108,330 3,830 6.00 28.27 06/19~2002 28 113,500 4,010 Average 3,920 SerVices - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests w~ra performed in general accordance with applicable ASTM, AASHTO, or DOT test matho~. This report la exclusively for the use of the client indicated above and shall no{ be reproduced except in full without the written approval of Terracon, Test results transmitted herein ara only applicable ' to the actual samples tested at the location(s) referenced and ara not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 10 ~-~w~-~,.~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021061.0041 Service Date: May 22, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppeli, Texas Project Number: 94021061 8.901 Carpenter Frwy,, Suite #100 Dallas, Texas 75247 (214) 830-1010 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: Plant: On-Site Supplier: GTI Truck No: Ticket No: Mix I.D. No.: 2328 Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 4.0 Concrete Temperature? F: 75 Ambient Temperature, o F: 66 Plastic Unit Weight, pcf: 148.0 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 I 6.00 28.27 2 2 6.00 28.27 Sample Information sample Time: 8:50am Date Cast: May 22, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 300 Placement Method: Direct Discharge' Sample Locations: Sta. 13+15 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (PS0 05~29~2002 7 114,280 4,040 05/2912002 7 112,690 3,990 2 3 6.00 28.27 06/19/2002 2 4 6.00 28.27 06/19/2002 Average ~,_ 4,020 119,470 f 28 4,220 28 116,700 Services - Obtain samples of fresh concrete at the p acement locations, perform required field tests and cast compressive strength samples. The te~s ~ performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report la exclusively for the usa of the client indicated above and shall no~ be reproduced except In full without the written approval of Termcon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of o~her apparently similar or idenllcal materials. Page 2 of 10 e,~..~ CONCRETE cOMPRESSIVE STRENGTH TEST Report Number: 94021061.0041 Service Date: May 22, 2002 Client: Transwestem Commemial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Finny., Suite #100 Dallas, Texaa 75247 (214) 630-1010 Mater~al Information Specified Strength: 3000 psi (~ 28 Days Batch Time: Plant: On-Site Supplier: GTI Truck No: Ticket No: Mix I.D. No.: 2328 Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 4.2 Concrete Temperature? F: 75 Ambient Temperature, o F: 80 Plastic Unit Weight, pcf: 147.8 Laboratory Test Data Set Specimen Diameter No. ID (inches) 3 1 6.00 3 2 6.00 Sample Information Sample Time: 9:40am Date Cast: May 22, 2002 Technician: Marvin Arandia Weather Conditions: Clear Accumulative Yards: 450 Placement Method: Direct Discharge Sample Locations: Sta. 14+30 Placement Location: See page 1 3 3 6.00 3 4 6.00 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age at Maximum Compressive Area Date Test Load Strength (sq. in.es) Tested (days) (lbs) (psi) 28.27 05/29/2002 7 106,140 3,750 28.27 05~29~2002 7 105,200 3,720 Average 3,740 28.27 06/19/2002 28 120,630 4,270 · 28.27 06/19/2002 28 119,380 4,220 Average 4,250 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were pedormed in general accordance with applicable ASTM, AASHTO, or DOT teat methods. This repo~ is exclusively for the use of the client indicated above and shall nol be reproduced excapl in full without the written approval of Terraccn. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not nece~__~_rily indicative of the properties of other apparently simlisr or identical materials. Page 3 of 10 CONCRETE COMPRESSIVE STRENGTH TEST ,Report Number: 94021061.0041 Service Date: May 22, 2002 Client: Transwestem Commemial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number:. 94021061 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3000 psi (~ 28 Days Batch Time: Plant: On-Site Supplier: GTI Track No: Ticket No: Mix I.D. No.: 2328 Field Test Data Test Sample Information Sample Time: 10:35am Date Cast: May 22, 2002 Technician: Marvin Arandia Weather Conditions: Partly cloudy Accumulative Yards: 600 Placement Method: Direct Discharge Sample Locations: Sta. 15+10 Placement Location: See page 1 Specification Result Slump, inches: 3.50 Air Content, %: 4.7 Concrete Temperature, o F: 80 Ambient Temperature, o F: 78 Plastic Unit Weight, pcf: 147.6 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. i.nches) Tested (days) 4 1 6.00 28.27 05/29/2002 7 4 2 6.00 28.27 05/29/2002 7 4 3 6.00 28.27 06/19~2002 4 4 6.00 28.27 06119/2002 Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Maximum Compressive Load St(~h (~bs) 108,840 3,850 107,880 3,810 Average 3,830 28 124,130 4,390 28 121,460 4,300 Average 4,300 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test rnathods. This repod la exclusively for the use of the client indicated above and shall nat be reproduced except in full without the written approval of Terracon. Test results transmitted herein ara o~ applicable to the actual samples tested at the Iocafien(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materlala. Page 4 of 10 o,.~we~,, ~ CONCRETE COMPRESSIVE STRENGTH TEST ,Report Number: 94021061.0041 Service Date: May 22, 2002 Client: Transwestem Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Suite 600W Dallas TX 75244 Report Date: June 20, 2002 Project: Northpoint Drive & Associated Utilities Coppell, Texas Project Number: 94021061 8901 Carpenter Rwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Material Information Specified Strength: 3000 psi ~ 28 Days Batch Time: Plant: On-Site Supplier: GTI Truck No: Ticket No: Mix I.D. No.: 2328 Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 4.6 Concrete Temperature,° F: 80 Ambient Temperature, o F: 77 Plastic Unit Weight, pcf: 148.2 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 5 1 6.00 28.27 5 2 6.00 28.27 5 3 6.00 28.27 5 4 6.00 28.27 Sample Information Sample Time: 11:30am Date Cast: May 22, 2002 Technician: Marvin Arandia Weather Conditions: Partly cloudy Accumulative Yards: 750 Placement Method: Direct Dischaq~e Sample Locations: Sta. 12+00 Placement Location: See page 1 Specification Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 ASTM C-138 Age at Maximum Compressive Date ' Test Load Strength Tested (days) (lbs) (ps~. 05/29/2002 7 126,560 4,480 05/29/2002 7 123,800 4,380 Average 4,430 06/19/2002 28 130,500 4,610 06/19/2002 28 134,300 4,750 Average 4,680 · Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use of the cllant indicated above and shell not be reproduced except in full without the written approval of Ten'ac=n. Test results transm~ed herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 10