Amberpoint BP-LR020701CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021029.0292
Service Date: MaY 31, 2002
Client: Transwestem Commemial Services
Attn: Jim Gaspard
5001 Spring ValleY Rd Ste 600W
Dallas TX 75244
8901 Carpenter Finny., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: July 01, 2002
Project: Amberpoint Building No. 1
Amberpoint Bus. Pk. ~ Coppell
Coppell, TX
Project Number: 94021029
Material Information
Specified Strength: 3000 psi ~ 28 Days
Batch Time: 10:41am Plant: 16
Supplie~. Potter Concrete
TrUck No: 106
Mix I.D. No.: 9337
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature, o F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Set Specimen
No. ID
I 1
1 2
Ticket No: 613917
Sample Information
Sample Time: 10:55am Date Cast: May 31,2002
Technician: Eric Garcia
Weather Conditions:
Accumulative Yards: 15
Placement Method: Pump
Sample Locations: Top left of grade beams ~ B.9/0-1
Placement Location: Grade beams ~ B.9-0.1 and M.710-1; 3
columns ~ B.6 Line and 2 columns ~ N
line (N/l, N.6/1)
I 3
I 4
I 5
Result Specification Test Method
5.00 ASTM C-143
85 ASTM C1064
88 ^STM C-1064
Age at Maximum Compressive
Diameter Area Date Test Load St.rength
(inches) (sq. inches) Tested (days) (lbs)
(P.~)
6.00 28.27 06/07/2002 7 100,230 3,540
6.00 28.27 06/07/2002 7 96,420 3,410
Average 3,480
6.00 28.27 06)28/2002 28 123,720 4,380
6.00 28.27 06/28/2002 28 133,700 4,730
Average 4,560
07/26/2002 56
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Eric Garcia
Report Distribution:
(1) Transweatern Commercial Services
(1) O'Brie~ & Asenc
(1) Tec. hntStxuctures
(1) c~y of copl~l - Conatr tnsp
(1) City of C~ - Bldg Insp
(1) Hill & ~lldnson
(1) Halff Aesoc In=
(1) State Farm Insurance
Reviewed by:
HB~ Enug~glan~ .
Prin~lpat
The tests were perf.-meal in general acco~lance with apldtcabis ASTM, AASHTO, or DOT t~t mat~xls. This repod is ex~uatvaty for lhe use of the client
indicated above and shall not be reproduced eXCel~ in full without Me written approval of Teffacon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referefx~d and are n~ necessarily indicative of the properties of ath~ apl~a~tly almiiar or identical.
materials.
Page 1 of 1