Amberpoint BP-LR020627CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021029.0291
Service Date:* May 29, 2002
Client: Transwestem Commercial Services
Attn: Jim Gaspard
5001 Spdng Valley Rd Ste 600W
Dallas TX 75244
8901 Carpenter Fn~/., Suite #100
Daltse, Tex~ 75247
(214) 630-1010
Report Date: June 27, 2002
Project: ~mberooint Building No. 1
--Amberpom~ ou=. ~-~. ~ Coppell
Coppell, TX
Project Number: 94021029
Material Information
Specified Strength: 3000 psi ~ 28 Days
Batch Time: 9:22am
Supplier: Hanson
Truck No: 1031
Mix I.D. No.: 9373
Plant: 22
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Resu~
4.25
1.3
89
76
Set Specimen Diameter Area
NO. ID (inches) (sq. inches)
1 I 6.00 28.27
1 2 6.00 28.27
1 3 6.00 28.27
I 4 6.00 28.27
Ticket No: 52792
Sample Information
Sample Time: 11:55am Date Cast: May 29, 2002
Technician: Bradford Rengstorff
Weather Conditions: Clear
Accumulative Yards: 5
Placement Method: Direct Discharge
Sample Locations: See placement location
Placement Location: Pier Hole Q/2.8
Specification
5-7
N/A
Test Method
ASTM C-143
ASTM C-231
ASTM C1064
ASTM C-1064
Date
Tested
06/01/2002
Age at Maximum Compressive
Test Load Strength
(days) ~lbs) (ps0 .
3 88,560 3,130
06/05/2002
06/26/2002
06/26/2002
7 119,380 4,220
28 156,340 ~' 5,530
Average
NOTE:
Concrete placed was over two (2) hours old.
Services - Obtain samples of fresh concrete at the
strength samples.
Technician: Bradford Rengstorff
Report Distribution:
(1) Transwestern Commercial Services
(1) O'Bhen & Aseoc
(1) TechniStructurse
(1) City of Coppell - Constr Inep
pla ' rm required field tests and cast compressive
Reviewed by:
(1) City of Coppell - Bldg Inep
(1) Hill & W#kineon
(1) Halff Aseoc Inc
(1) State Farm Insurance
HBC Eng7
E Eugene Herbour
Principal
The tests w~re perfem~ed in general a~x~3rdence with applicable ASTM, AASHTO, or DOT test metheds: This report ia exclusively for the use of the client
indicated above and shal} not be reproduced excep~ in full without the written approval of Terracon. Test results transmitted herein ere only applicatfle
to the actual semplse tested at the Iocatlo~(e) referenced and ere no~ necessarily indicative of the properties of ofher apparently similar or identical
materials.
Page 1 of 1