Loading...
CF-Coppell Rd SC-LR020604 (2)H0oper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS CLIENT: Texas Unified Constructors, Inc. PROJECT: Field Service Offices & Maint. Fac., Coppell LOCATION OF POUR SET 1: Slab for wash bay floor LOCATION OF POUR SET 2: JOB NO.: DATE: SUPPLIER: 01.1054 4 June 2002 La~imom SAMPLE DATA: SET 1 Truck No. 1032 Ticket No. 7117262 Time Batched 11:35am Time Sampled 12:30pm Concrete Temp. IASTM ClOe4) 83°F Air Content (ASTM C231} 4.1% Unit Weight (ASTM C138) SET 2 MIX NO. Cement Fiyash Sand in. 1.0 in. Water Admix//1 Admix//2 AEA 64 COMPRESSIVE STRENGTH TESTS {ASTM Cylinder Slump Age Teat Number Inchea Days Date (ASTM C143) (Standard 6 inch x 12 inch cylinder) Total Load Compressive Required Pounds Strength 28-Day psi Strength 263 4.75 7 06/11~2 264 4.75 28 07~2/02 265 4.75 28 07/02/02 71,100 2520 101,400 3590 99,700 3530 28-Day Average 3560 350O TECHNICIAN: DISTRIBUTION: JLS (11:30am-1:30pm) (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallaa, Texas 75229 (214) 351-6419 Fax (214) 351-5148