CF-Coppell Rd SC-LR020531 (2)Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPORT OF MORTAR/GROUT TESTS
CLIENT: Texas Unified Construc,tprs, Inc._
PROJECT: Field Service Offices & Maintenance Fac.
Coppell, TX
LOCATION OF POUR SET 1:
LOCATION OF POUR SET 2:
JOB NO.:
DATE:
SUPPLIER:
01.1054
31 May 2002
Quality Masonry
Block wall, final run over main entrance to service area
SAMPLE DATA: SET 1
Truck No.
Ticket No.
Time Batched
Time Sampled 11:30am
Mortar Temp. (ASTM C10641 81 °F
Air Content (ASTM C173)
Unit Weight (ASTM C138)
SET 2 MIX NO. Type "S" Mortar
Cement
Cement
Sand
in.
1.0 in.
Water
Admix//1
Admix//2 '
AEA
COMPRESSIVE STRENGTH TESTS {ASTM C39)
Cube Row Age Test
Number % Days Date
(Standard 2 inch x 2 inch x 2 inch Cube)
Total Load compressive Required
Pounds Strength 28-Day
psi Strength
253
254
255
TECHNICIAN:
7 06/07/01 8,600 ~1~ 2150
28 06/28/01 13,000 [~$0
28 06/28/01 .12,.100 '""3030
28-Day Average 3140
7
DISTRIBUTION:
(3) City of Coppell
(1) Vidaud & Associates
(1) Doyle Engineering Group
(1) Texas Unified Constructors, Inc.
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148