Loading...
PA0001-LR020321Ro gineers Client: 8908 Ambassador Row Dallas, Texas 7524%4510 (2 [4) 630-9745 {214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST American Civil Constructors~ Inc. ACm: Mr. Rex Shelley 821 E. Southlake Blvd. Southlake TX 76092 Report No.: ! 4587 I Project No.: 025955 Date of Service: 03/13/2002 Report Date: 03/21/2002 Project: Services: McArthur Park Parking Expansion Coppeli, TX Obtain samples of flesh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: American Civil Constructors CONCRETE SUPPLIER: Hanson PLA~: 29 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days STRENGTH: SLUMP (in): AIR (%): TEST METHOD: ASTM C- 172 ASTM C-31 ASTM C- 143 ASTM C-231 ASTM C- 1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 9339 PLACEMENT DATE: 03/1'3/2002 WEATHER CONDITIONS: Clear TIME SAMPLED: 1:45pm BATCH TIME: NA TEMPERATURE (F) - AIR 70 F CONCRETE: 78 F TRUCK NO: 1092 TICKET NO: 41929 AIR CONTENT (%): 5.0 UNITWEiGHT(t~0: NA OVERALL PLACEMENT LOCATION: Paving - northwest side handicap ramp SAMPLE LOCATION: 10' north x 2' west of southeast REPORT OF TESTS co~ner of paving Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP SET NO. (inche~) 1 I 5.0 1 2 5.0 1 3 5.0 Technician: Anthony Maldonado R~ort Distribution: (I) American Civil Constructors, Inc. (l) City of Coppell MAXIMUM DATE AGE LOAD TESTED (days) (Ib~ force) 03/20/2002 7 71200 04/10/2002 28 04/10/2002 28 Started: 12:30pm COMPRESSIVE STRENGTH FRACTURE (l~i) TYPE 2520 Unbonded Cap Finished: 2:30pm Unbonded Cap Unbonded Cap Ro~ya,~, Inc: p ~k Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided tbr testing. We assume no responsibility for variation in quality (composition, appearance, pertbrmance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports ate for the exclusive usa of the ¢lionts to whom they are addressed and shall not be reproduced except in thll without the written approval of Rone Engineers. Inc. 01OK Page I ofl RoneEnugine ers 8908 Ambassador Row Dallas, Texas 7524%4510 (214) 6~0-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: American Civil Constxuctors, Inc. Attn: Mr. Rex Shelley 821 E. Southlake Blvd. $outhlake TX 76092 Report No.: 145865 Project No.: 025955 Date of Service: 03/13/2002 Report Date: 03/21/2002 Project: Services: McArthur Park Parking Expansion Coppeil, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: COt~rRACTOR: American Civil Constructors CONCRETE SUPPLIER: Hallson pLANT: 29 SPZCIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3" - $" NA ASTM C-172 ASTM Co31 ASTM C-143 ASTM C-23 I ASTM C- 1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 9339 PLACEMENT DATE: 03/13/2002 WEATHER CONDITIONS: Clear TIME SAMPLED: 1 1:40am BATCH TIME: 10:35am TEMPERATURE (F) - AIR 65 F CONCRETE: 70 F TRUCK NO: 1888 TICKET NO: 41918 AIR CONTENT (%): 5.0 [INIT WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: paving - south side, sidewalk southeast comer of parking lot SAMPLE LOCATION: REPORT OF TESTS 25' north x I' west of southeast comer of sidewalk Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MARKED SET NO. 1 1 5.0 1 2 5.0 I 3 5.0 MEASURED SLUMP (inches) T~hnician: Anthony Maldonado Report Dim'ibution: ([) American Civil Constructors, Inc. ([) CiO/of CoppeH MAXIMUM COMPRESSIVE DATE AGE LOAD STRENGTH FRACTURE TESTED (days) (lbs. force) (psi) TYPE 03/20/2002 7 78060 2760 Unbonded Cap 04/10/2002 28 Unbonded Cap 04/10/2002 28 Unbonded Cap Started: ll:30am Finished: 12:30pm Ron//~c. "~Clay Stark ' Project Manager UMITATIONS: The test results presented herein were prepared based upon the specific samples pmvided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons .or condi.tions over wh. ich we have no~ontrol~ Ou.r Icttc~ and ~ports are for the exclusive use of the clients to whom they are addressed and .shall not he reproduced except In full without the written approval olRonc ~ngmecrs. mc. 01DK Page 1 of I