Loading...
PA0001-LR020225RoneEngineers Client: American Civil Constructors, Inc. Atto: Mr. Rex Shelley 821 E. Southlake Blvd. Southlake TX 76092 Project: Services: McArthur Park Parking Expansion Coppell, TX Perform In-Place Density Test in accordance with ASTM Standards. PROJECT DATA 8908 Ambassador Row Dallas, Texas 75247-4S10 (214) 630-9745 (214) 630-9819 (fax) IN-PLACE DENSITY TESTING Report No.: 144092 Project No.: 025955 Date of Service: 02/18/2002 Report Date: 02/25/2002 CONTRACTOR: T,qt Methods: American Civil Constructors Gauge: Truxler-3430 Moisture Gauge Serial No: 31580 Current: 678 Te~t Mode: DT Previous: 691 MOISTURE DENSITY RELATIONS Maximum M/D No. Description Moisture % Density pcf 1 Dark Brown Clay 20.5 l 01.0 ASTM D-2922 ASTM D-3017 2 Dark Brown Clay 19.0 103.0 FIELD DENSITY TESTS Standard Counts Density Current: 2303 Previous: 2799 Project Requirements Moisture Density +2 / +4 92 - 98 +2 / +4 92 - 98 TEST PROBE NO TEST LOCATION DEPTH Paving Subgrade South area, NW comer, final grade Paving Subgrade South area, SW comer, final grade Paving Subgrade South area, center south side, final grade Paving Subgrade South area center north side, final grade Paving Snbgrade South area, northeast comer, final grade Paving Snbgrade South area, southeast corner, final grade M/D MOISTURE %VET DENSITY DRY DENSITY DENSITY NO. (%) (pod (pc0 (% max) 6" 2 14.8' 118.2 103.0 100' 6" 2 12.5' 124.3 110.5 107 * 6" 2 17.2' 121.5 103.7 101 * 6" 2 20.8* 121.3 100.4 97 6" 2 20.4* 118.6 98.5 96 6" 2 16.4' 119.3 102.5 100 * UMITATIONS: The test results present~l herein were prepared based upon th~ specific samples provided t'or testing. We assume no responsibility for variation in quality (composition, appearance performance, etc.) or any other feature of similar subjcct mattcr provided by pcrsons .or condJ!ions ovcr wh. ich we havc,no~c..onm:)l.:,O~.r Ictte~ and repom are for the exclusive use oftbe clients to whom they ate addressed and sha not be reproduced except tn full wzthout the written npprovm OtKone *-ngmecrs, mc. 07CM Page I of 2 Report No.: 144092 RoneEngineers Project No.: 025955 Client: American Civil Constructors, Inc. Iii An asterisk (*) appears next to test resul~ which do NOT meet the project specifications. Density test over 102% may be due to mismatch of material or low moisture content. Teehnieian: Chris Webber Report Distribution: (1) Amcrican Civil Constructors, Inc. (1) City of Coppoll Started: 5:lSpm Finished: 6:30pm LIMITATIONS: The test results presented heroin were prepared based upon thc s~ciflc samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, p~rfonnancc etc.) or any other feature of similar subject matter provided by porsons or conditions over wh. ich we have no control. Ou.r letters and reports ate for the exclusive usc of the clients to whom they ate addressed and_shall n~ot .b~rcproduccd except in full without thc written approval of Ronc Engineers. Inc. 07CM rage · ow~