Amberpoint BP-LR020701 (2)FIELD DENSITY TESTING Report Number: 94021029.0301 Service Date: June 10, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 8901 Carpenter FnNy. Suite #100 Dallas, Texas 75247 (214) 630-1010 Repo~l~'-July 01, 2002 No. 1 ~ Pr~L~t: Amberpoint Building (IF- Amh-moint Bus. Pk. @ Coppell J Coppell, ~ x Project Number: 94021029 Material Information Material Laborator~ No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pc0 (%) (% compaction) 1. 210290004 ASTM D-698 Dk brown clay 22.4 99.9 -1/+3 95 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pct) (% compaction) Ramp and Parking Lot 302 Grid line B.5/0.7 at Grade 1 6 21.9 101.4 100+ 303 Grid line B.5/0.3 at Grade I 6 22.6 100.6 100+ 304 Grid line C.2/0.8 at Grade 1 6 22.3 97.3 97 305 Gdd line D.9/0.8 at Grade 1 6 21.5 99.8 100 306 Gdd line F.5/0.8 at Grade I 6 21.7 96.5 97 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method~STM D2922, ASTM D3017 Gauge ID: Field Results Reported To: Contractor/Brian Technician: Bradford Rengstorff Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Assoc , (1) TechniStructures (1) City of Coppell - Constr Insp (1) City of Coppell - BIdg Insp Reviewed by: H BC Eng~j (1) Hill & Wilkinson (1) Halff Assoc Inc Eugene Harbour (1) State Farm Insurance Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 FIELD DENSITY TESTING Report Number: 94021029.0306 Service Date: June 11,2002 8901 Carpenter F,'wy., Suite//100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 01, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Material Laboratory Content Weight Range Unit Weight No. Test Method Description and Classification . (%) (pc0 (%) (% compaction) 1. 210290004 ASTM D-698 Dk brown clay 22.4 99.9 -1/+3 95 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcO (% compaction) Ramp and Parking Lot 307 Grid line M.5/0.8 at Grade 1 6 21.6 100.6 100+ 308 Grid line M.5/0.4 at Grade I 6 21.9 99.4 99 309 Gdd line L.5/0.8 at Grade 1 6 22.6 99.6 100 310 Gdd line J.5/0.8 at Grade I 6 21.7 98.4 98 311 Grid line 1.5/0.8 at Grade I 6 22.4 97.7 98 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: Field Results Reported To: Contractor/Brian Technician: Bradford Rengstorff Report Distribution: (1) Transwestern Commercial Services (1) O'Bden & Assoc (1) TechniStructures (1) City of Coppell - Constr Insp (1) City of Coppell - BIdg Insp (1) Hill & Wilkinson (1) Halff Assoc Inc (1) State Farm insurance Reviewed by: HBC Eng~ Eugene Harbour Pri~.~pal The tests were performed in general accordance with applicabte ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1