Loading...
CF-Coppell Rd SC-LR020514 (2)Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF MORTAR/GROUT TESTS JOB NO.: 01.1054 CLIENT: Texas Unified Constructors, Inc. / DATE: 14 May 2002 PROJECT: Field Service Offices & Maintenance Fac. SUPPLIER: Quality Masonry for City of Coppell, TX LOCATION OF POUR SET 1: Two masonry columns at north side of utility storage building LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX N0. Grout Truck No. Ticket No. Time Batched Time Sampled CiroUt Temp. (ASTM C1064) Air Content (ASrM c23t1 Unit Weight IasrM ct3el 12:30pm 83°F Cement Flyash Sand in. 1.0 in. Water Admix #1 Admix H2 AEA COMPRESSIVE STRENGTH TESTS (ASTM c3sl (Standard 3 inch x 3 inch x 6 inch Prism) Prism Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM C143) psi Strength 243 10.00 7 05/21 /02 15,500 830 244 10.00 ~ 06/1 1 /02 25, 000 245 10.00 28 06/11/02 27,000 1 246 10.00 07/09/02 28,50Q 28-Day Average 3010 3000 Co ~~ . y ~``~ ZaOZ ` ~~~ TECHNICIAN: JLS (11:30am-1:30pm) DISTRIBUTION: (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 /rJ~--' (214) 351-6419 Fax (214) 351-5148