Loading...
Amberpoint BP-LR020710FIELD DENSITY TESTING Report Number: 94021029.0324 Service Date: June 27, 2002 ENC, INF~E.I~ 8901 Carpenter Frwy.., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 10, 2002 Project:Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Material Laboratory Content Weight Range Unit Weight No. Test Method Description and Classification (%) (pct~ (%) (% compaction) 1. ASTM D-698 Brown clay 22.4 99.9 0/+4 92 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pc0 (% compaction) Tilt Wall Leaveout 320 Grid line A.1/4 1st 1 6 22.9 94.2 94 321 Grid line A.1/4 2nd 1 6 23.0 92.1 92 322 Grid line A.1/4 3rd 1 6 22.4 93.0 93 323 Grid line A.1/4 4th 1 6 24.9 92.9 93 324 Grid line A.1/8 1st 1 6 23.6 93.4 93 325 Grid line A.1/8 2nd 1 6 23.9 94.2 94 326 Grid line A.1/8 3rd 1 6 24.1 95.0 95 327 Grid line A.1/8 4th 1 6 23.8 94.0 94 328 Grid line 11/D 1st 1 6 24.1 92.9 93 329 Grid line 11/D 2nd 1 6 25.1 93.1 93 330 Grid line 11/D 3rd I 6 24.0 92.4 92 331 Grid line 11/D 4th 1 6 22.3 * 94.0 94 Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method~,STM D2922, ASTM D3017 Gauge ID: Technician: William M. Rice Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Assoc (1) TechniStructuras (1) City of Coppell - Conatr Insp (1) City of Coppell - Bldg [nsp (1) Hill & Wilkinson (1) Halff Assoc Inc (1) State Farm Insurance Reviewed by: Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 oTs~7~.K.~