Amberpoint BP-LR020711FIELD DENSITY TESTING Report Number: 94021029.0327 Service Date: June 28, 2002 ]_~NGINEEPdNG 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 11,2002 Project:Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. ASTM D-698 Dk & reed clay w/rock 24.6 92.3 =/> +3 92 2. ASTM D-698 Reddish brown clayey sandy w/limestone 22.2 97.0 -1/+3 95 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pot) (% compaction) 332 Grid line O/10.9 1st I 6 29.5 91.2 99 333 Grid line L/10.9 1st 1 6 27.8 86.4 94 334 Grid line J/10.9 2nd 1 6 28.9 92.6 100 335 Grid line G.5/10.9 2nd 1 6 27.6 88.5 96 336 Grid line F/10.9 at Grade 2 6 21.2 97.2 100 337 Grid line D/10.9 at Grade 2 6 24.4 94.3 97 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method~STM D2922, ASTM D3017 Gauge ID: Technician: Phillip R. Green Report Distribution: (1) Transwestern Commercial Services (1) O'Brien & Associates Inc (1) TechniStructures (1) City of Coppell - Constr Insp HBC Eng~ (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson Ltd Reviewed by: (1) Halff Assoc Inc Eugene Hard,our (1) State Farm insurance Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0303 Service Date: June 11,2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 ENGINF~ERING 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 11,2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 5:31am Supplier: Potter Truck No: 105 Mix I.D. No.: 7752 Plant: 16 Ticket No: 614051 Accumulative Yards: Placement Method: Sample Locations: Placement Location: Sample Information Sample Time: 6:15am Date Cast: June 11,2002 Technician: Joseph B. Gordon Weather Conditions: Clear 10 Direct Discharge See placement location Paving- NW corner of building to SW corner of building & SW corner of building to SW loading dock to 20' W of W wall Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.75 4.2 76 74 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 I 6.00 28,27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Services - Sample location: 30' S of NW corner of building & 12'W of W wall Specification Test Method 4-6 ASTM C-143 3-6 ASTM C-231 ASTM Cl 064 ASTM C- 1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 06/18/2002 7 101,050 3,570 06/1812002 7 101,490 3,590 Average 3,580 07/09/2002 28 129,010 4,560 07/09/2002 28 129,100 4,570 Average 4,570 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, e~-~w~o,-~,,~. Page 1 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0303 Service Date: June 11, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 11, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 6:27am Plant: 16 Supplier: Potter Truck No: 105 Mix I.D. No.: 7752 Ticket No: 059 Sample Information Sample Time: 7:05am Date Cast:June 11,2002 Technician: Joseph B. Gordon Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: See page I Sample location: 70' S of NW corner of building & 6' W of W wall Field Test Data Test Result Specification Test Method Slump, inches: 6.00 4-6 ASTM C-143 Air Content, %: 4.6 3-6 ASTM C-231 Concrete Temperature,o F: 76 ASTM C1064 Ambient Temperature, o F: 73 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 06/18/2002 7 102,780 3,630 2 2 6.00 28.27 06/18/2002 7 108,480 3,840 Average 3,740 2 3 6.00 28.27 07/09/2002 28 116,500 4,120 2 4 6.00 28.27 07/09/2002 28 120,430 4,260 Average 4,190 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 O~LW~,-F,~,,, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0303 Service Date: June 11,2002 8901 Carpenter Frwy,, Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 11,2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:11am Plant: 16 Supplier: Potter Truck No: 112 Mix I.D. No.: 7752 Ticket No: 614072 Sample Information sample Time: 9:05am Date Cast: June 11,2002 Technician: Joseph B. Gordon Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: See page 1 Sample location: 40' N of SW corner of building & 12' W of W wall Field Test Data Test Result Specification Test Method Slump, inches: 5.75 4-6 ASTM C-143 Air Content, %: 4.1 3-6 ASTM C-231 Concrete Temperature, o F: 85 ASTM Cl 064 Ambient Temperature, o F: 82 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 06/18/2002 7 101,670 3,600 3 2 6.00 28.27 06/18/2002 7 102,900 3,640 Average 3,620 3 3 6.00 28.27 07/09/2002 28 133,840 4,730 3 4 6.00 28.27 07/09/2002 28 127,610 4,510 Average 4,620 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, er DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties- of other apparently similar or identical materials. Page 3 of 4 o,.~Lw~0~-r.~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0303 Service Date: June 11,2002 ENGI NEEP. ING 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 11, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 9:21am Plant: 16 Supplier: Potter Truck No: 112 Mix I.D. No.: 7752 Ticket No: 614080 Sample Information Sample Time: 10:10am Date Cast:June 11,2002 Technician: Joseph B. Gordon Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: SW loading dock, 10' S of S wall Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches:' 6.00 4-6 ASTM C-143 Air Content, %: 4.5 3-6 ASTM C-231 Concrete Temperature,° F: 83 ASTM C1064 Ambient Temperature, o F: 79 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 1 6.00 28.27 06/18/2002 7 108,520 3,840 4 2 6.00 28.27 06/18/2002 7 102,470 3,620 Average 3,730 4 3 6.00 28.27 07/09/2002 28 130,980 4,630 4 4 6.00 28.27 07/09/2002 28 132,550 4,690 Average 4,660 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Joseph B. Gordon Report Distribution: (1) Transwestem Commercial Services (1) O'Brien & Assoc (1) TechniStructures (1) City of Coppell - Constr Insp (1) City of Coppell - BIdg Insp (1) Hill & Wilkinson (1) Halff Assoc Inc (1) State Farm Insurance Reviewed by: HBC Engi~~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4