SC-Coppell MSW-LR020716FUGRO SOUTH, INC. -/. ~ 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972} 620-7326 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell lSD ~ Report Date: July 16, 2002 PROJECT: ~.p~g1~'~-ce, Center, C0~ Project No.: 0701-2233 SAMPLE DATE: July 8, 2002 CONTRACTOR: K.. A. Sparks TICKET NO.: 188435 AMBIENT TEMP. (°F): 95 CONCRETE TEMP. (°F) (ASTM C-1064): 102 TIME BATCHED: 10:18 TIME SAMPLED: 11:10 WEATHER CONDITION: Clear LOCATION OF PLACEMENT: CONCRETE SUPPLIER: Hanson PLANT/TRUCK: 27/923 MIX ID NUMBER: 9349 AIR (%) (ASTM C-231): WATER ADDED (gal): 20 SLUMP (in.) (ASTM C-143) .' 5.75 Slab on grade entryway CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CSC 233 7 07/15/02 91500 3240 4000/28 days CSC 234 28 08/05/02 CSC 235 28 08/05/02 CSC 236 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof ~ [~ [~ E~] Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Dan Gazley FUGRO SOUTH INC. SMH/rm Distribution: Reviewed By: ~ -- K A Sparks Contractors Inc. - Jim Schooler K A Sparks Contractors Inc. - Rick McKinney (Fax: 972-462-9320) City of Coppell - Lee Stone City of Coppell - Garreth Campbell J Coppell lSD - Mickey Harper SHW Group - Mike Elmore SHW Group - Dale Lilljedahl