Loading...
SC-Coppell MSW-LR020711FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell lSD Report Date: July 11, 2002 PROJECT: Coppell lSD Service Center, Coppell, Texas Project No.: 0701-2233 SAMPLE DATE: June 25, 2002 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C-1064)' TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K. A. Sparks 4:00 4:00 East walkway CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASTM C-231): WATER ADDED (gal): SLUMP (in.) (ASTM C-143): Hanson 27/923 9349 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL LOAD COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE (pounds) STRENGTH STRENGTH NUMBER (days) TESTED (psi) (psi) CSC 211 14 07/09/02 149650 5290 4000/28 days CSC 212 14 07/09/02 144200 5100 CSC 213 28 07/23/02 CSC 214 28 07/23/02 CSC 215 Hold CSC 216 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof r;~ ~-~ [--~ ~ Cudng: Methods: ASTM C-39 Fracture: AI/NJ [/'xJ V___J LIB C D REMARKS: Cylinders cast by Contractor. All information except test data furnished by Contractor and assumed to be correct. Technician: SMH/rm Distribution: Dan Gazley FUGRO SOUTH INC. Reviewed By: ~ K A Sparks Contractors Inc. - .Jim Schooler K A Sparks Contractors Inc. - Rick McKinney {Fax: 972-462-9320) City of Coppell - Lee Stone City of Coppell - Garreth Campbetff'~ Coppell lSD o Mickey Harper SHW Group - Mike Elmore SHW Group - Dale Lilljedahi