ST0001-LR020724RoneEngineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Arm: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 152862 Project No.: 015729 Date of Service: 06/24/2002 Report Date: 07/24/2002 Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP On): AIR (%): TEST METHOD: CONTRACTOR: Lvlfi~sLrucB. lre Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 7 SPECIFICATION REQUIREMEI~rs 3000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 838 PLACEMENT DATE: 06/24/2002 WEATHER CONDITIONS: SBHlly TIME SAMPLED: 9:40am BATCH TIME: 8:3 lam TEMPERATURE (F) - AIR 92 F CONCRETE: 87 F TRUCK NO: 947 TICKET NO: 7 ! 17905 AIR CONTENT (%): 4.0 UNIT WEIGHT (PC0: NA OVERALL PLACEMENT LOCATION: Creekview St, 3 drainage inlets with curb; Station 23+50 to Station 23+99, Station 4+46 to Station 4+95 and Station 21+45 to Station 21+94 SAMPLE LOCATION: Station 23+88 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP SET NO. (inches) MAXIMUM DATE AGE LOAD TESTED (days) (lbs. force) COMPRESSIVE STRENGTH (psi) 1 1 5.0 1 2 5.0 1 3 5.0 07/01/2002 7 81355 2880 07/22/2002 28 113530 ~4010 07/22/2002 28 112125 l~3970 Average ~"3990 Unbonded Cap UnbondedCap UnbondedCap 1 4 Hold Locations provided by contractor. Technician: Daryl Garret Report Distribution: (I) City of Coppell ( l ) C~i'ty'o f Coppell (1) Infrastructure Services, Inc. (1) Schriekel, Rollins & Assoc., Inc. Started: 8:15am Finished: I l:30am Rone c ay rk Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 1 ofl