ST0001-LR020722 ineers RoneEng 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630=9745 (214) 630-9819 (fax) IN-PLACE DENSITY TESTING Client: Project: Services: City of Coppell At-m: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Creekview Drive and Freeport Parkway Coppell, TX Perform In-Place Density Test in accordance with ASTM Standards. Report No.: 153990 Project No.: 015729 Date of Service: 07/11/2002 Report Date: 07/22/2002 PROJECT DATA CONTRACTOR: Infrastructure Services, Inc. Test Method~: ASTM D-2922 ASTM D-3017 M/D No. Description Gauge: Troxler 3430 Moisture Gauge Serial No: 31705 Current: 711 Teat Mode: DT Previous: NA MOISTURE DENSITY RELATIONS Maximum Moisture % Density pcf Dark Brown Clay, trace organics and gravel (Lime treated) 22.5 96.5 FIELD DENSITY TESTS Standard Counts Density Current: 2828 Previous: NA Project Requirements Moisture Density Optimum +5 95 mia TEST NO Technician: Alex Urbiaa, AET Report Distribution: (1) ciW of Coppell (1) City of Coppell (1) Infrastxucture Services, Inc. (1) Schrickel, Rollins &Assoc., Inc. PROBE TEST LOCATION DEPTH No. (%) (pc0 Paving Subgrade State Drive, Station 36+50, center, f'mal 6" 1 24.1 117.0 Test results on this report meet project specification. Started: 9:00am Finished: 11:00a Rone E~/g~ M/D MOISTURE WET DENSITY DRY DENSITY 94.3 Projcc~ Ma LIMITATIONS: The test results presented herein were prepared based upon flae specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall no/be reproduced except in full without the written approval of Rone Engineers, Inc. 07DK Page 1 of 1 RoneEngineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) REPORT OF CYLINDER COLLECTION Client: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Project'~ Creekvie~lI Drive and Freeport Parkway Coppell, TX Services: Cylinder Collection Report No.: 154200 Project No.: 015729 Date of Service: 07/13/2002 Report Date: 07/22/2002 Report of Collection On this date, a Rone Engineers, Inc. representative arrived on site as scheduled to pick up compressive strength test specimen cast prior to this date. Technician Time: 8:45 a.m. - 9:30 a.m. Page 1 of 1 Technician: Marvin Hanks Report Distribution: (1) City of Coppell (l) City of Coppell (1) Infrastructure Services, Inc. (1) Schrickel, Rollins & Assoc., Inc. Clay St Project Manager LIMITATIONS: The test results preseuted herein were prepared based upon the specific samples provided lbr testing. We assume no responsibility tbr variatiou m qualit.x (composition, appearance, pertbrmance, etc,) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters aud reports are for the exclusive use of tile clients to whom they are addressed anti shall uot be reproduced except in tull without the written approval of Roue Eugineers. Inc. 99DF Page I of I Ro gineers 8908 Ambassador Row Dallas, Texas 75247-4510 {214} 630-9745 {214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Report No.: 154140 Attn: Ms. Susan Taylor - Engineering Dept Project No.: 015729 PO Box 478 Date of Service: 07/12/2002 Coppell TX 75019 ~ Report Date: 07/22/2002 Creekview Drive and Treeport ym ~.,, Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): A1R (%): TEST METHOD: CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 6 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3"- $" 3% - 5% ASTM C- 172 ASTM C-31 ASTM C- 143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 38 PLACEMENT DATE: 07/12/2002 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 9:00am BATCH TlME: 7:58am TEMPERATURE (F) - AIR 83 F CONCRETE: 86 F TRUCKNO: 1123 TICKETNO: 6179001 AIR CONTENT (%): NA UNIT WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: Grade beam from Station 1+50.32 through Station 4+05.32 SAIVIPLE LOCATION: Station 2+75 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 2 1 3.5 07/19/2002 7 88220 3120 Unbonded Cap 2 2 3.5 08/09/2002 28 Unbonded Cap 2 3 3.5 08/09/2002 28 Unbonded Cap 2 4 Hold _~ /~ Technician: Jarrod Miller. Started: 6:30am Finished: 9:00am goner, . Report Distribution: (1) City of Coppell (1) City of Coppell ~,in~l l~ 7~ ~~~l~r ~."~ Clap Stark (1) Infrastructure Services, Inc. ~ al~l[ ~iect Manage''~ ' r (1) S.f~ri.ckel, Rollins & Assoc., Inc. LIMITATIONS: The test resalts preseated he were prepared based u , the specific samples provided tar testiug. We assnme no responsibility for variation in qualit.~ {composition, appearance, pertbrmance~ etc,) or any other feature of similar sul/iect manet provided by persons or conditions over which we have no control, Our leners aad reporB are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except ia t'u]l without the writtea approval of Roae Eugineers. Inc. 01DK Page 2 of 2 RoneEn gineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: CiVJ of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 154247 Project No.: 015729 Date of Service: 07/12/2002 Report Date: 07/22/2002 Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to thc laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 6 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3"-5" 3% - 5% ASTM C- 172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C- 1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 42 PLACEMENT DATE: 07/12/2002 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 7:35am BATCH TIME: 6:27am TEMPERATURE (F)- AIR 74 F CONCRETE: 82 V TRUCK NO: 939 TICKET NO: 6178989 AIR CONTENT (%): 3.] UNIT WEIGHT (pcfL NA OVERALL PLACEMENT LOCATION: Paving on State from Station 36+22.55 tbroagh Station 36+22.45 SAMPLE LOCATION: Station 36+22.50 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12' (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 I 4.5 1 2 4.5 1 3 4.5 1 4 4.5 Technician: Jarrod Miller Report Distribution: (1) City of Coppell (1) City of Coppell (1) Infrastructure Services, Inc. (1) S~g~13~ri.ckel, Rollins & Assoc., Inc. 07/15/2002 3 99455 07/19/2002 7 105470 08/09/2002 28 08/09/2002 28 Started: 6:30am Finished: 9:00am Pro 3520 Unbonded Cap 3730 Unbonded Cap Unbonded Cap Unbonded Cap lay Stark ect ganager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation ia qeality (composition, appearance, pertbnnance, etc.) or any other feamro of similar subject matter provided by persons or conditions over which we have no control Our letters and reports are tbr tbe exclusive use of the clients to whom they are addressed and shall not be reproduced except ia Ii. tH without tl~c written approval of Rone Engineers. lac. 01DK Page I of I RoneEn g 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 154140 Project No.: 015729 Date of Service: 07/12/2002 Report Date: 07/22/2002 Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Infrastructure Services, Inc. CONCRETE SUPPLIER: Lattimore PLANT: 6 SPECIFICATION REQUIREMENTS 3000 psi ~ 28 Days 3"-$" 3% - 5% ASTM C- ! 72 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C- 1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 38 PLACEMENT DATE: WEATHER CONDITIONS: TIME SAMPLED: 8:10am TEMPERATURE (F) - AIR TRUCK NO: 76 l AIR CONTENT (%): 3.1 07/12/2002 Partly cloudy BATCH TIME: 7:04am 84 F CONCRETE: 86 F TICKETNO: 6178991 UNIT WEIGHT (pcf}: NA OVERALL PLACEMENT LOCATION: Sidewalk from Station 12+00 through Station 15+00 SAMPLE LOCATION: Station 13+00 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MAXIMUM COMPRESSIVE MARl(ED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 5.5 07/19/2002 1 2 5.5 08/09/2002 1 3 5.5 08/09/2002 1 4 Hold 7 93770 3320 Unbonded Cap 28 Unbonded Cap 28 Unbonded Cap L[MITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility lbr variation in quality (composition, appearance, peri'brmance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive ase of the clients to whom they are addressed and shall not be reproduced except in ftflI without the written approval oi" Rone Engineers. Inc. 01DK Page I of 2