Amberpoint BP-LR020719CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021029.0338 Service Date: July 11,2002 8901 Carpantar Frwy., Suite/1100 Dallas, Taxas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 19, 2002 Project' Amberpoi,n.t Buildipn No. 1 ~ -- Amberpoint Bus. Pk. @ Coppeil Coppell, TX Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:32am Supplier: Hanson Truck No: 1015 Mix I.D. No.: 7752 Plant: 27 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Ticket No: 188569 Sample Information sample Time: 9:20am Date Cast: July 11,2002 Technician: Joseph B. Gordon Weather Conditions: Clear Accumulative Yards: 20 Placement Method: Direct Discharge Sample Locations: 13' N of SW curb @ NE entrance to project Placement Location: Paving NE entrance to project Result Specification Test Method 5.00 5.0 Max ASTM C-143 4.7 3-6 ASTM C-231 87 ASTM Cl 064 84 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 07/18/2002 7 104,740 3,700 1 2 6.00 28.27 07/18/2002 7 106,870 3,780 Average 3,740 1 3 08/08/2002 28 1 4 08/08/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Joseph B. Gordon Report Distribution: (1) Transwestern Commercial Services (1) TechniStructures (1) City of Coppell -Constr Insp (1) City o[ Coppel[ - BIdg Insp (1) Halff Assoc Inc (1) State Farm insurance (1) Hill & Wilkinson, Ltd. (1) O'Brien & Associates, Inc. Reviewed by: 'HBC Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST · Report Number: 94021029.0310 Service Date: June 20, 2002 ENGINEEP, iNG 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 19, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 4:33am Supplier: Potter Truck No: 104 Mix I.D. No.: 7752 Plant: 16 Ticket No: 614136 Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Sample Information Sample Time: 4:33am Date Cast: June 20, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 30 Placement Method: Pump Sample Locations: See placement location Placement Location: Pavement- S & SE of building (See attached sketch) Field Test Data Test Result Specification Test Method 5.00 ASTM C-143 82 ASTM C1064 76 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 06/27/2002 7 126,650 4,480 1 2 6.00 28.27 06/27/2002 7 121,780 4,310 Average 4,400 1 3 6.00 28.27 07/18/2002 28 151,240 5,350 1 4 6.00 28.27 07/18/2002 28 149,250 5,280 Average 5,320 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5 CONCRETE COMPRESSIVE STRENGTH TEST · Report Number: 94021029.0310 Service Date: June 20, 2002 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 L~NGINEER~NG 8901 Carpenter Frw,/., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: July 19, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 5:37am Supplier: Potter Truck No: 107 Mix I.D. No.: 7752 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory'Test Data Result 6.00 80 77 Ticket No: 614145 Sample Information sample Time: 6:00am Date Cast: June 20, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 120 Placement Method: Pump Sample Locations: See page 1 Placement Location: Pavement- SW of building & S & SE of building Specification Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 2 1 6.00 28.27 08/27/2002 2 2 6.00 28.27 06/27/2002 2 3 6.00 28.27 07/18/2002 2 4 6.00 28.27 07/18/2002 Test Method ASTM C-143 ASTM C 1064 ASTM C-1064 Age at Test (days) Maximum Compressive Load Strength (lbs) (psi) 7 98,850 3,500 7 100,940 3,570 Average 3,540 28 125,970 4,450 28 128,830 4,560 Average 4,510 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5 CONCRETE COMPRESSIVE STRENGTH TEST · Report Number: 94021029.0310 Service Date: June 20, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 19, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 7:09am Supplier: Potter Truck No: 104 Mix I.D. No.: 7752 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 6.00 80 79 Ticket No: 614157 Sample Information Sample Time: 7:40am Date Cast: June 20, 2002 Technician: Marvin R. Arandia Weather Conditions: Partly cloudy Accumulative Yards: 240 Placement Method: Pump Sample Locations: See page 1 Placement Location: Pavement- S & SE of building Specification Test Method Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 3 1 6.00 28.27 06/27/2002 3 2 6.00 28.27 06/27/2002 3 3 6.00 28.27 07/18/2002 3 4 6.00 28.27 07/18/2002 ASTM C-143 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 107,180 3,790 7 111,850 3,960 Average 3,880 28 135,740 4,800 28 134,320 4,750 Average 4,780 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 3 of 5 CONCRETE COMPRESSIVE STRENGTH TEST · Report Number: 94021029.0310 Service Date: June 20, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 19, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project 'Number: 94021029 Ma terial Information Specified Strength: 4000 psi @ 28 Days Batch Time: 8:30am Supplier: Potter Truck No: 108 Mix I.D. No.: 7752 Plant: 16 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.00 80 84 Set Specimen Diameter Area No. ID (inches) (sq. inches) 4 1 6.00 28.27 4 2 6.00 28.27 4 3 6.00 28.27 4 4 6.00 28.27 Ticket No: 614165 Sample Information Sample Time: 9:20am Date Cast:June 20, 2002 Technician: Marvin R. Arandia Weather Conditions: Partly cloudy Accumulative Yards: 320 Placement Method: Direct Discharge Sample Locations: See page 1 Placement Location: Pavement- S & SE of building Specification Test Method ASTM C-143 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 06/27/2002 7 110,190 3,900 06/27/2002 7 111,200 3,930 Average 3,920 07/18/2002 28 131,720 4,660 07/18/2002 28 136,230 4,820 Average 4,740 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5 CONCRETE COMPRESSIVE STRENGTH TEST · Report Number: 94021029.0310 Service Date: June 20, 2002 E. NG]NF~ER]~ 8901 Carpenter Frw¥., Suite #100 Dallas, Texas 75247 (214) 630-! 010 Client: Transwestern Commercial Services Attn: Jim Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: July 19, 2002 Project: Amberpoint Building No. 1 Amberpoint Bus. Pk. @ Coppell Coppell, TX Project Number: 94021029 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 10:35am Plant: 16 Supplier: Potter ' Truck No: 420 Mix I.D. No.: 7752 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 614175 Sample Information Sample Time: 11:00am Date Cast: June 20, 2002 Technician: Marvin R. Arandia Weather Conditions: Partly cloudy' Accumulative Yards: 420 Placement Method: Pump Sample Locations: See page 1 Placement Location: Pavement- SW of building Result Specification Test Method 5.75 ASTM C-143 85 ASTM C1064 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 5 1 6.00 28.27 06/27/2002 5 2 6.00 28.27 06/27/2002 5 3 6.00 28.27 07/18/2002 5 4 6.00 28.27 07/18/2002 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 95,640 3,380 7 106,540 3,770 Average 3,580 28 127,300 4,500 28 120,130 4,250 Average 4,380 Services - Obtain samples of fresh concrete at the placement locations, per/orm required field tests and cast compressive strength samples. Technician: Marvin R. Arandia Report Distribution: (1) Transwestern Commercial Services (1) TechniStructures (1) City of Coppell - Constr Insp (1) City of Coppell - Bldg Insp HBC Eng~0g-'~ (1) Halff Assoc Inc (1) State Farm Insurance Reviewed by: (1) Hill & Wilkinson, Ltd. (1) O'Brien & Associates, Inc. Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5 0~-LLW,~-F.~o PROJECT: PROJECTNO.: CALCD. BY: CHKD BY: DATE: DATE: ENGINEERING, 1NC.