Loading...
PA9702-LR 990922 H3C GROUT COMPRESSI /E STRENGTH TEST 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 09/07/1999 Report No.: 9924214 Report Date 09/22/1999 Client No.: COPPELL Project No.: 94991118 Client: City of Coppell Project: CoppellAquatic/RecreationCtr Attn: Brad Reid 300 Block of Parkway Blvd 732 DeForest Coppell TX 75019 Coppell, Texas/Prj. #96051 Services: Sample grout from delivery vehicle, cast 3" x Y' x 6" prisms in accordance with the recommendations of ASTM C 1019. PROJECT DATA CONTRACTOn: Hisaw & Assoc. GROUT CLASS: Grout GROUT SUPPLIER: TXI PLACEMENTDATE: 09/07/1999 BATCH TIME: 8:30am PLANT: On-site TIME SAMpLED: 9:00am BY: Mike Odom SPECIFICATION REQUIREMENTS WEATHER cox~rorrIoNs: Partly cloudy SXRENGTH: 2500psi @ 28 Days TEMrERATURE(F)-Am 83 F GROUT: 82 F TRUCK NO: N/A TICKET NO: N/A TEST METHOD: ASTMC1019 PLACEMENTLOCATION: Same as sample location SAMPLE LOCATION: See below for sample location SAMPLE SIZE: 3"x3"x6" REPORT OF TESTS PRISM MEASURED MAXIMUM COMPRESSIVE MARKED SLUMp DATE AGE LOAD STRENGTH SET NO. (inches) TESTED (days) (lbs. force) (psi) 1 1 9.50 09/14/1999 7 50220 3810 I 2 9.50 10/05/1999 28 1 3 9.50 10/05/1999 28 Sample Location: Line F gym south wall at 22 feet, line B.1 ~ym north wall at 22 feet. Technician: Mike Odom Started: 7:30am Finished: 9:30am Engine Inc. Report Distribution: (D City of Coppell (l) City ofCoppell - Engineerlag (I) BrinkIcy Sargent Architects (1) City of Coppell - Bldg. lnsp. Eugene Harbour (1) Turner Engineers (I) City ofCoppell - Leisure Serv Dept Vice President (I) Hisaw & Associates This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the writZen approval of HBC Engineering, Inc. 09TMP Page I of 1 l¸ r I'