Loading...
PA9702-LR 990908 CONCRETE COMPRF IVE STRENGTH ENGIN ~, INC. 8901 Carpenter Frwy., Suite Dallas, Texas 75247 Date of Service: 08/30/1999 Report No.: 9923473 Report Date 09/08/1999 Client No.: COPPELL ProjectNo.: 94991118 Client: City of Coppell Project: Coppell Aquatic/Recreation Ctr Attn: BradReid 300BlockofParkwayBlvd 732 DeForest Coppell TX 75019 Coppell, Texas/Prj. #96051 Services: ~btainsamp~es~ffreshc~ncreteatthep~acement~~cati~ns~perf~rmrequired~e~dtestandcast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw & Assoc. CONCRETE CLASS: N/A CONCRETE SUPPLIER: NelsonBros. PLACEMENTDATE: 08/30/1999 BATCH TIME: ll:50am PLANT: N/A TiME SAMPLED: 12:45pm BY: Del Ratliff SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Hot,clear STRENGTH: 4000 psi @ 28 Days TEMPERATURE (F) - AIR 99 V CONCRETE: 94 F SLUMP: 5.0" TRUCK NO: 216 TICKET NO: 77105 AIR: N/A AIRCONTENT(%): N/A UNITWEIGHT(pc0: N/A TEST METHOD: ASTM C- 143 PLACEMENT LOCATION: Pump pit walls ASTM C-172 ASTM C-39 SAMPLE LOCATION: 5' N of SW pit comer REPORT OF TESTS ACCUMULATIVE Y~a~S: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (Ibs. force) (psi) TYPE 1 l 5.00 09/06/1999 7 144900 5120 1 2 5.00 09/06/1999 7 139630 4940 Average 5030 1 3 5.00 09/27/1999 28 1 4 5.00 09/27/1999 28 Report Distribution: (I) City of Coppell (1) City ofCoppell - Engineering (I) Brinkley Sargent Architects (1) City ofCoppell - Bldg. Insp. EU (I) Turner Engineers (1) City ofCoppell - Leisure Serv Dept Vice President (I) Hisaw & Associates This report is exclusively tbr the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc, 01T~I Page I of I